Validity of Wearable Inertial Sensors for Gait Analysis: A Systematic Review

被引:1
|
作者
Prisco, Giuseppe [1 ]
Pirozzi, Maria Agnese [2 ]
Santone, Antonella [1 ]
Esposito, Fabrizio [2 ]
Cesarelli, Mario [3 ]
Amato, Francesco [4 ]
Donisi, Leandro [2 ]
机构
[1] Univ Molise, Dept Med & Hlth Sci, I-86100 Campobasso, Italy
[2] Univ Campania Luigi Vanvitelli, Dept Adv Med & Surg Sci, I-80138 Naples, Italy
[3] Univ Sannio, Dept Engn, I-82100 Benevento, Italy
[4] Univ Naples Federico II, Dept Informat Technol & Elect Engn, I-80125 Naples, Italy
关键词
agreement; biomechanics; gait analysis; inertial measurement units; wearable sensors; VALIDATION; ACCELEROMETER; PARAMETERS; KINEMATICS; GYROSCOPE; EVENTS; MOTION;
D O I
10.3390/diagnostics15010036
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Gait analysis, traditionally performed with lab-based optical motion capture systems, offers high accuracy but is costly and impractical for real-world use. Wearable technologies, especially inertial measurement units (IMUs), enable portable and accessible assessments outside the lab, though challenges with sensor placement, signal selection, and algorithm design can affect accuracy. This systematic review aims to bridge the benchmarking gap between IMU-based and traditional systems, validating the use of wearable inertial systems for gait analysis. Methods: This review examined English studies between 2012 and 2023, retrieved from the Scopus database, comparing wearable sensors to optical motion capture systems, focusing on IMU body placement, gait parameters, and validation metrics. Exclusion criteria for the search included conference papers, reviews, unavailable papers, studies without wearable inertial sensors for gait analysis, and those not involving agreement studies or optical motion capture systems. Results: From an initial pool of 479 articles, 32 were selected for full-text screening. Among them, the lower body resulted in the most common site for single IMU placement (in 22 studies), while the most frequently used multi-sensor configuration involved IMU positioning on the lower back, shanks, feet, and thighs (10 studies). Regarding gait parameters, 11 studies out of the 32 included studies focused on spatial-temporal parameters, 12 on joint kinematics, 2 on gait events, and the remainder on a combination of parameters. In terms of validation metrics, 24 studies employed correlation coefficients as the primary measure, while 7 studies used a combination of error metrics, correlation coefficients, and Bland-Altman analysis. Validation metrics revealed that IMUs exhibited good to moderate agreement with optical motion capture systems for kinematic measures. In contrast, spatiotemporal parameters demonstrated greater variability, with agreement ranging from moderate to poor. Conclusions: This review highlighted the transformative potential of wearable IMUs in advancing gait analysis beyond the constraints of traditional laboratory-based systems.
引用
收藏
页数:24
相关论文
共 50 条
  • [21] Advances in the application of wearable sensors for gait analysis after total knee arthroplasty: a systematic review
    Feng, Yuguo
    Liu, Yu
    Fang, Yuan
    Chang, Jin
    Deng, Fei
    Liu, Jin
    Xiong, Yan
    ARTHROPLASTY, 2023, 5 (01)
  • [22] Advances in the application of wearable sensors for gait analysis after total knee arthroplasty: a systematic review
    Yuguo Feng
    Yu Liu
    Yuan Fang
    Jin Chang
    Fei Deng
    Jin Liu
    Yan Xiong
    Arthroplasty, 5
  • [23] Validity and Reproducibility of Inertial Physilog Sensors for Spatiotemporal Gait Analysis in Patients With Stroke
    Lefeber, Nina
    Degelaen, Marc
    Truyers, Chris
    Safin, Iwona
    Beckwee, David
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2019, 27 (09) : 1865 - 1874
  • [24] Objective Measures of Ataxic Gait Using Wearable Inertial Sensors
    El-Gohary, M.
    Horak, L.
    Gomez, C.
    MOVEMENT DISORDERS, 2018, 33 : S292 - S292
  • [25] Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review
    Poitras, Isabelle
    Dupuis, Frederique
    Bielmann, Mathieu
    Campeau-Lecours, Alexandre
    Mercier, Catherine
    Bouyer, Laurent J.
    Roy, Jean-Sebastien
    SENSORS, 2019, 19 (07)
  • [26] Gait Analysis Using Wearable Sensors
    Tao, Weijun
    Liu, Tao
    Zheng, Rencheng
    Feng, Hutian
    SENSORS, 2012, 12 (02) : 2255 - 2283
  • [27] Gait Analysis Using Wearable Sensors
    Bhosale, Tanmav
    Kudale, Hemant
    Kumthekar, Varun
    Garude, Shreyash
    Dhumal, Prasad
    2015 INTERNATIONAL CONFERENCE ON ENERGY SYSTEMS AND APPLICATIONS, 2015, : 267 - 269
  • [28] Estimation of Step Length and Gait Asymmetry Using Wearable Inertial Sensors
    Wang, Lei
    Sun, Yun
    Li, Qingguo
    Liu, Tao
    IEEE SENSORS JOURNAL, 2018, 18 (09) : 3844 - 3851
  • [29] Gait Variability in Spinocerebellar Ataxia Assessed Using Wearable Inertial Sensors
    Shah, Vrutangkumar V.
    Rodriguez-Labrada, Roberto
    Horak, Fay B.
    McNames, James
    Casey, Hannah
    Floyd, Kyra Hansson
    El-Gohary, Mahmoud
    Schmahmann, Jeremy D.
    Rosenthal, Liana S.
    Perlman, Susan
    Velazquez-Perez, Luis
    Gomez, Christopher M.
    MOVEMENT DISORDERS, 2021, 36 (12) : 2922 - 2931
  • [30] Recent Advances in Quantitative Gait Analysis Using Wearable Sensors: A Review
    Hutabarat, Yonatan
    Owaki, Dai
    Hayashibe, Mitsuhiro
    IEEE SENSORS JOURNAL, 2021, 21 (23) : 26470 - 26487