Validation of High-Resolution Continuum Source Flame Atomic Absorption Spectrometry for Determination of Selected Toxic Metals in the Decontamination Process of Wastewater Discharged in Natural Receivers

被引:0
|
作者
Senna, Bame Sanah [1 ]
Masamba, Wellington [1 ]
Obuseng, Veronica [2 ]
Frentiu, Tiberiu [3 ,4 ]
Angyus, Bogdan Simion [5 ]
Covaci, Eniko [3 ,4 ]
机构
[1] Botswana Int Univ Sci & Technol, Fac Sci, Dept Chem & Forens Sci, Plot 10071 Khurumela Ward,Private Bag 16, Palapye, Botswana
[2] Univ Botswana, Fac Sci, Dept Chem, Plot 4775 Notwane Rd,Private Bag UB 022, Gaborone, Botswana
[3] Babes Bolyai Univ, Fac Chem & Chem Engn, Arany Janos 11, Cluj Napoca 400028, Romania
[4] Babes Bolyai Univ, Res Ctr Adv Anal Instrumentat & Chemometr, Arany Janos 11, Cluj Napoca 400028, Romania
[5] Natl Inst Res & Dev Optoelect INOE 2000 INCD Bucha, Res Inst Analyt Instrumentat, Donath 67, Cluj Napoca 400293, Romania
关键词
High-resolution continuum source flame atomic absorption spectrometry; inductively coupled plasma optical emission spectrometry; toxic metal; water analysis; method validation;
D O I
10.17344/acsi.2023.8534
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new method based on high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS) was validated for the determination of selected toxic metals in wastewater resulting from mining activity, compared to induc-tively coupled plasma optical emission spectrometry (ICP-OES) and line-source flame atomic absorption spectrometry (LS FAAS). The HR-CS FAAS method was characterized by detection limits (LODs) in the range (mu g L-1) 1(Mn)-30(Pb), better than ICP-OES for Cu, Fe, Ni, Co, Pb and Mn, and poorer for Cd, Zn and Cr. Dunnett's test showed that both methods were not affected by significant bias against certified values. The recovery in the HR-CS FAAS method was in the range of 98-103% with relative extended uncertainty of 9-18% and precision of 2-11%. Compared to LS FAAS, the HR-CS FAAS presented better LODs for Pb and Cr. The HR-CS FAAS method is suitable for determining selected toxic elements in filtered water samples without any chemical treatment
引用
收藏
页码:500 / 508
页数:9
相关论文
共 50 条
  • [41] High-resolution continuum source quartz tube/flame atomic absorption spectrometry method with broad applicability for the comprehensive assessment of selected toxic elements content in recyclable (bio) plastic materials
    Szeredai, Bettina Dora
    Frentiu, Tiberiu
    Ponta, Michaela
    Muntean, Norbert
    Covaci, Eniko
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2024, 218
  • [42] Progress in the determination of metalloids and non-metals by means of high-resolution continuum source atomic or molecular absorption spectrometry. A critical review
    M. Resano
    M. R. Flórez
    E. García-Ruiz
    Analytical and Bioanalytical Chemistry, 2014, 406 : 2239 - 2259
  • [43] Progress in the determination of metalloids and non-metals by means of high-resolution continuum source atomic or molecular absorption spectrometry. A critical review
    Resano, M.
    Florez, M. R.
    Garcia-Ruiz, E.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (9-10) : 2239 - 2259
  • [44] Determination of Sulfur in Plant Using a High-Resolution Continuum Source Atomic Absorption Spectrometer
    Wang Yu
    Li Jia-xi
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (05) : 1418 - 1421
  • [45] Application of high-resolution continuum source flame atomic absorption spectrometry to reveal, evaluate and overcome certain spectral effects in Pb determination of unleaded gasoline
    Kowalewska, Zofia
    Laskowska, Hanna
    Gzylewski, Michal
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 132 : 26 - 36
  • [46] Multi-Element Determination of Trace Elements in B7-diesel Oil by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry
    dos Santos, Heldiane S.
    de Jesus, Alexandre
    Laroque, Diane O.
    Piatnicki, Clarisse M. S.
    da Silva, Marcia M.
    BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 8 (30): : 59 - 70
  • [47] The chemical generation of NO for the determination of nitrite by high-resolution continuum source molecular absorption spectrometry
    Brandao, Geovani C.
    Lima, Daniel C.
    Ferreira, Sergio L. C.
    TALANTA, 2012, 98 : 231 - 235
  • [48] High-resolution continuum source electrothermal absorption spectrometry of AlBr and CaBr for the determination of bromine
    Huang, Mao Dong
    Becker-Ross, Helmut
    Florek, Stefan
    Heitmann, Uwe
    Okruss, Michael
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (05) : 566 - 570
  • [49] Determination of macro- and micronutrients in plant leaves by high-resolution continuum source flame atomic absorption spectrometry combining instrumental and sample preparation strategies
    Oliveira, Silvana R.
    Gomes Neto, Jose A.
    Nobrega, Joaquim A.
    Jones, Bradley T.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (04) : 316 - 320
  • [50] Use of slurry sampling for the direct determination of zinc in yogurt by high resolution-continuum source flame atomic absorption spectrometry
    Brandao, Geovani C.
    de Jesus, Raildo M.
    da Silva, Erik G. P.
    Ferreira, Sergio L. C.
    TALANTA, 2010, 81 (4-5) : 1357 - 1359