Validation of High-Resolution Continuum Source Flame Atomic Absorption Spectrometry for Determination of Selected Toxic Metals in the Decontamination Process of Wastewater Discharged in Natural Receivers

被引:0
|
作者
Senna, Bame Sanah [1 ]
Masamba, Wellington [1 ]
Obuseng, Veronica [2 ]
Frentiu, Tiberiu [3 ,4 ]
Angyus, Bogdan Simion [5 ]
Covaci, Eniko [3 ,4 ]
机构
[1] Botswana Int Univ Sci & Technol, Fac Sci, Dept Chem & Forens Sci, Plot 10071 Khurumela Ward,Private Bag 16, Palapye, Botswana
[2] Univ Botswana, Fac Sci, Dept Chem, Plot 4775 Notwane Rd,Private Bag UB 022, Gaborone, Botswana
[3] Babes Bolyai Univ, Fac Chem & Chem Engn, Arany Janos 11, Cluj Napoca 400028, Romania
[4] Babes Bolyai Univ, Res Ctr Adv Anal Instrumentat & Chemometr, Arany Janos 11, Cluj Napoca 400028, Romania
[5] Natl Inst Res & Dev Optoelect INOE 2000 INCD Bucha, Res Inst Analyt Instrumentat, Donath 67, Cluj Napoca 400293, Romania
关键词
High-resolution continuum source flame atomic absorption spectrometry; inductively coupled plasma optical emission spectrometry; toxic metal; water analysis; method validation;
D O I
10.17344/acsi.2023.8534
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new method based on high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS) was validated for the determination of selected toxic metals in wastewater resulting from mining activity, compared to induc-tively coupled plasma optical emission spectrometry (ICP-OES) and line-source flame atomic absorption spectrometry (LS FAAS). The HR-CS FAAS method was characterized by detection limits (LODs) in the range (mu g L-1) 1(Mn)-30(Pb), better than ICP-OES for Cu, Fe, Ni, Co, Pb and Mn, and poorer for Cd, Zn and Cr. Dunnett's test showed that both methods were not affected by significant bias against certified values. The recovery in the HR-CS FAAS method was in the range of 98-103% with relative extended uncertainty of 9-18% and precision of 2-11%. Compared to LS FAAS, the HR-CS FAAS presented better LODs for Pb and Cr. The HR-CS FAAS method is suitable for determining selected toxic elements in filtered water samples without any chemical treatment
引用
收藏
页码:500 / 508
页数:9
相关论文
共 50 条
  • [31] Feasibility of high-resolution continuum source molecular absorption spectrometry in flame and furnace for sulphur determination in petroleum products
    Kowalewska, Zofia
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (07) : 546 - 556
  • [32] VERSATILE, HIGH-RESOLUTION CONTINUUM SOURCE ATOMIC-ABSORPTION FLAME SPECTROMETER WITH RESONANCE FLAME DETECTOR
    BLACKBURN, MB
    WINEFORDNER, JD
    CANADIAN JOURNAL OF SPECTROSCOPY, 1982, 27 (05): : 137 - 140
  • [33] Feasibility of high-resolution continuum source molecular absorption spectrometry for vanadium determination
    Kowalewska, Zofia
    Abad, Carlos
    Okruss, Michael
    Recknagel, Sebastian
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (02) : 472 - 483
  • [34] Evaluation of Lines of Phosphorus and Potassium by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry for Liquid Fertilizer Analysis
    Ferreira, Roberta Borges
    Oliveira, Silvana Ruella
    Franzini, Vanessa Pezza
    Virgilio, Alex
    Raposo Junior, Jorge Luiz
    Gomes Neto, Jose Anchieta
    ATOMIC SPECTROSCOPY, 2011, 32 (02) : 56 - 61
  • [35] HIGH-RESOLUTION CONTINUUM SOURCE ATOMIC-ABSORPTION SPECTROMETRY IN AN AIR-ACETYLENE FLAME WITH PHOTODIODE ARRAY DETECTION
    JONES, BT
    MIGNARDI, MA
    SMITH, BW
    WINEFORDNER, JD
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (07) : 647 - 651
  • [36] Evaluation of lines of boron, phosphorus and sulfur by high-resolution continuum source flame atomic absorption spectrometry for plant analysis
    Bechlin, Marcos Andre
    Gomes Neto, Jose Anchieta
    Nobrega, Joaquim Araujo
    MICROCHEMICAL JOURNAL, 2013, 109 : 134 - 138
  • [37] Determination of Iron and Zinc in Garbanzo by Microwave Digestion-High Resolution Continuum Source Flame Atomic Absorption Spectrometry
    Liu, Quan-de
    Chen, Shang-long
    Li, Yong
    Gao, Jing
    Zhu, Yun-xu
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON ADVANCED DESIGN AND MANUFACTURING ENGINEERING, 2015, 39 : 1004 - 1007
  • [38] Slurry sampling and high-resolution continuum source flame atomic absorption spectrometry using secondary lines for the determination of Ca and Mg in dairy products
    Brandao, Geovani C.
    Matos, Geraldo D.
    Ferreira, Sergio L. C.
    MICROCHEMICAL JOURNAL, 2011, 98 (02) : 231 - 233
  • [39] High-resolution continuum source AAS: the better way to perform atomic absorption spectrometry
    Welz, B
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (01) : 69 - 71
  • [40] High-resolution continuum source AAS: the better way to perform atomic absorption spectrometry
    Bernard Welz
    Analytical and Bioanalytical Chemistry, 2005, 381 : 69 - 71