High-resolution continuum source quartz tube/flame atomic absorption spectrometry method with broad applicability for the comprehensive assessment of selected toxic elements content in recyclable (bio) plastic materials

被引:0
|
作者
Szeredai, Bettina Dora [1 ,2 ]
Frentiu, Tiberiu [1 ,2 ]
Ponta, Michaela [1 ,2 ]
Muntean, Norbert [1 ,2 ]
Covaci, Eniko [1 ,2 ]
机构
[1] Babes Bolyai Univ, Fac Chem & Chem Engn, Arany Janos 11, Cluj Napoca 400028, Romania
[2] Babes Bolyai Univ, Res Ctr Adv Anal Instrumentat & Chemometr, Arany Janos 11, Cluj Napoca 400028, Romania
关键词
Atomic absorption spectrometry; Toxic element; Recyclable material; (bio)polymeric material; ELECTRONIC EQUIPMENT; BIODEGRADABLE MATERIALS; MERCURY DETERMINATION; HEAVY-METAL; WASTE; ANTIMONY; SAMPLES; LEAD; HG; CONTAMINATION;
D O I
10.1016/j.sab.2024.106995
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A method with broad applicability for evaluating the content of As, Sb Bi, Hg, Cd, Cu, Zn, Sr, Mn, Ni, Cr, Co and Pb was developed for the characterization of recyclable (bio)polymeric materials of various types and origins based on high-resolution continuum source atomic absorption spectrometry after high-pressure microwave-assisted wet digestion in H2SO4-HNO3-H2O2 mixture. The limits of detection (LODs) for As, Sb Bi and Hg were in the range 0.005-0.020 mg kg(-1) after chemical vapour generation and quartz tube atomization, while for the other elements determined in air-acetylene flame were 0.1-1.5 mg kg(-1). The recoveries were in the range 95-105% with extended uncertainty of 9-21% (k = 2). Plastics of polyethylene terephthalate, polypropylene, polyethylene, epoxy resin, polyvinyl chloride and acrylonitrile butadiene styrene showed higher concentrations of the studied elements, but variable depending on the element, nature and origin of the polymeric materials. Biopolymeric or hybrid polymeric materials could represent a risk for at least one of the elements (As, Sb, Bi and Zn). The recycling of plastics from electronic products, medical activity, food and cosmetics packaging, office supplies and toys generate recyclable materials with concentrations of As, Sb, Bi, Cu and Zn higher than agriculture, domestic activities, and constructions, in which As and Sb were below the method LODs. Chromium, Co and Pb were below LOD in all samples. However, in all the (bio)polymeric recyclable materials considered in this study, the concentrations of the elements were below the limits imposed by European regulations, regardless of their origin and use. Tukey's statistical test showed both significant and not significant differences (p > 0.05) among the content of elements in materials with concentration above the LODs of the method.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] A practical method for the determination of sulphur in coal samples by high-resolution continuum source flame atomic absorption spectrometry
    Baysal, A.
    Akman, S.
    TALANTA, 2011, 85 (05) : 2662 - 2665
  • [2] Validation of High-Resolution Continuum Source Flame Atomic Absorption Spectrometry for Determination of Selected Toxic Metals in the Decontamination Process of Wastewater Discharged in Natural Receivers
    Senna, Bame Sanah
    Masamba, Wellington
    Obuseng, Veronica
    Frentiu, Tiberiu
    Angyus, Bogdan Simion
    Covaci, Eniko
    ACTA CHIMICA SLOVENICA, 2024, 71 (03) : 500 - 508
  • [3] Unified analysis method for total and inorganic As determination in foodstuffs by hydride generation high-resolution continuum source quartz tube atomic absorption spectrometry
    Chirita, Lucia
    Covaci, Eniko
    Ponta, Michaela
    Frentiu, Tiberiu
    ANALYTICAL METHODS, 2023, 15 (13) : 1734 - 1746
  • [4] APPLICATION OF HIGH-RESOLUTION CONTINUUM SOURCE ATOMIC-ABSORPTION SPECTROMETRY TO THE ANALYSIS OF STANDARD REFERENCE MATERIALS
    MESSMAN, JD
    EPSTEIN, MS
    RAINS, TC
    BARNES, IL
    OHAVER, TC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1979, (APR): : 25 - &
  • [5] High-resolution continuum source electrothermal atomic absorption spectrometry: Linearization of the calibration curves within a broad concentration range
    Katskov, Dmitri
    Hlongwane, Miranda
    Heitmann, Uwe
    Florek, Stefan
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 71-72 : 14 - 23
  • [6] Optimization of high-resolution continuum source graphite furnace atomic absorption spectrometry for direct analysis of selected trace elements in whole blood samples
    Wojciak-Kosior, Magdalena
    Szwerc, Wojciech
    Strzemski, Maciej
    Wichlacz, Zoltan
    Sawicki, Jan
    Kocjan, Ryszard
    Latalski, Michal
    Sowa, Ireneusz
    TALANTA, 2017, 165 : 351 - 356
  • [7] Evaluation of Lines of Phosphorus and Potassium by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry for Liquid Fertilizer Analysis
    Ferreira, Roberta Borges
    Oliveira, Silvana Ruella
    Franzini, Vanessa Pezza
    Virgilio, Alex
    Raposo Junior, Jorge Luiz
    Gomes Neto, Jose Anchieta
    ATOMIC SPECTROSCOPY, 2011, 32 (02) : 56 - 61
  • [8] HIGH-RESOLUTION CONTINUUM SOURCE ATOMIC-ABSORPTION SPECTROMETRY IN AN AIR-ACETYLENE FLAME WITH PHOTODIODE ARRAY DETECTION
    JONES, BT
    MIGNARDI, MA
    SMITH, BW
    WINEFORDNER, JD
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (07) : 647 - 651
  • [9] Evaluation of lines of boron, phosphorus and sulfur by high-resolution continuum source flame atomic absorption spectrometry for plant analysis
    Bechlin, Marcos Andre
    Gomes Neto, Jose Anchieta
    Nobrega, Joaquim Araujo
    MICROCHEMICAL JOURNAL, 2013, 109 : 134 - 138
  • [10] Multi-Element Determination of Trace Elements in B7-diesel Oil by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry
    dos Santos, Heldiane S.
    de Jesus, Alexandre
    Laroque, Diane O.
    Piatnicki, Clarisse M. S.
    da Silva, Marcia M.
    BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 8 (30): : 59 - 70