High-resolution continuum source quartz tube/flame atomic absorption spectrometry method with broad applicability for the comprehensive assessment of selected toxic elements content in recyclable (bio) plastic materials

被引:0
|
作者
Szeredai, Bettina Dora [1 ,2 ]
Frentiu, Tiberiu [1 ,2 ]
Ponta, Michaela [1 ,2 ]
Muntean, Norbert [1 ,2 ]
Covaci, Eniko [1 ,2 ]
机构
[1] Babes Bolyai Univ, Fac Chem & Chem Engn, Arany Janos 11, Cluj Napoca 400028, Romania
[2] Babes Bolyai Univ, Res Ctr Adv Anal Instrumentat & Chemometr, Arany Janos 11, Cluj Napoca 400028, Romania
关键词
Atomic absorption spectrometry; Toxic element; Recyclable material; (bio)polymeric material; ELECTRONIC EQUIPMENT; BIODEGRADABLE MATERIALS; MERCURY DETERMINATION; HEAVY-METAL; WASTE; ANTIMONY; SAMPLES; LEAD; HG; CONTAMINATION;
D O I
10.1016/j.sab.2024.106995
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A method with broad applicability for evaluating the content of As, Sb Bi, Hg, Cd, Cu, Zn, Sr, Mn, Ni, Cr, Co and Pb was developed for the characterization of recyclable (bio)polymeric materials of various types and origins based on high-resolution continuum source atomic absorption spectrometry after high-pressure microwave-assisted wet digestion in H2SO4-HNO3-H2O2 mixture. The limits of detection (LODs) for As, Sb Bi and Hg were in the range 0.005-0.020 mg kg(-1) after chemical vapour generation and quartz tube atomization, while for the other elements determined in air-acetylene flame were 0.1-1.5 mg kg(-1). The recoveries were in the range 95-105% with extended uncertainty of 9-21% (k = 2). Plastics of polyethylene terephthalate, polypropylene, polyethylene, epoxy resin, polyvinyl chloride and acrylonitrile butadiene styrene showed higher concentrations of the studied elements, but variable depending on the element, nature and origin of the polymeric materials. Biopolymeric or hybrid polymeric materials could represent a risk for at least one of the elements (As, Sb, Bi and Zn). The recycling of plastics from electronic products, medical activity, food and cosmetics packaging, office supplies and toys generate recyclable materials with concentrations of As, Sb, Bi, Cu and Zn higher than agriculture, domestic activities, and constructions, in which As and Sb were below the method LODs. Chromium, Co and Pb were below LOD in all samples. However, in all the (bio)polymeric recyclable materials considered in this study, the concentrations of the elements were below the limits imposed by European regulations, regardless of their origin and use. Tukey's statistical test showed both significant and not significant differences (p > 0.05) among the content of elements in materials with concentration above the LODs of the method.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Method development for the determination of nickel in petroleum using line-source and high-resolution continuum-source graphite furnace atomic absorption spectrometry
    Vale, MGR
    Damin, ICF
    Klassen, A
    Silva, MM
    Welz, B
    Silva, AF
    Lepri, FG
    Borges, DLG
    Heitmann, U
    MICROCHEMICAL JOURNAL, 2004, 77 (02) : 131 - 140
  • [32] Determination of silicon in plant materials using direct solid sample analysis with high-resolution continuum source graphite furnace atomic absorption spectrometry
    Boschetti, Wiliam
    Dalagnol, Luiza M. G.
    Dullius, Mariana
    Zmozinski, Ariane V.
    Becker, Emilene M.
    Vale, Maria Goreti R.
    de Andrade, Jailson B.
    MICROCHEMICAL JOURNAL, 2016, 124 : 380 - 385
  • [33] An environmentally friendly approach for the characterization of construction materials: determination of trace, minor, and major elements by slurry sampling high-resolution continuum source graphite furnace atomic absorption spectrometry
    Gomez-Nieto, Beatriz
    Isabel-Cabrera, Carmen
    Gismera, Maria Jesus
    Sevilla, Maria Teresa
    Procopio, Jesus R.
    de Rojas, Maria Isabel Sanchez
    ANALYTICAL METHODS, 2023, 15 (09) : 1105 - 1115
  • [34] Validation of an analytical method based on the high-resolution continuum source flame atomic absorption spectrometry for the fast-sequential determination of several hazardous/priority hazardous metals in soil
    Tiberiu Frentiu
    Michaela Ponta
    Raluca Hategan
    Chemistry Central Journal, 7
  • [35] Validation of an analytical method based on the high-resolution continuum source flame atomic absorption spectrometry for the fast-sequential determination of several hazardous/priority hazardous metals in soil
    Frentiu, Tiberiu
    Ponta, Michaela
    Hategan, Raluca
    CHEMISTRY CENTRAL JOURNAL, 2013, 7
  • [36] Closed-Vessel Conductively Heated Digestion System for the Elemental Analysis of Agricultural Materials by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry (HR-CS FAAS)
    Traversa, Leonardo Clemente
    Santiago, Joao Victor Biagi
    de Oliveira, Evilim Martinez
    Ferreira, Edilene Cristina
    Virgilio, Alex
    Neto, Jose Anchieta Gomes
    ANALYTICAL LETTERS, 2023, 56 (15) : 2443 - 2456
  • [37] Method development for the determination of cadmium in fertilizer samples using high-resolution continuum source graphite furnace atomic absorption spectrometry and slurry sampling
    Borges, Aline R.
    Becker, Emilene M.
    Lequeux, Celine
    Vale, Maria Goreti R.
    Ferreira, Sergio L. C.
    Welz, Bernhard
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (07) : 529 - 535
  • [38] Straightforward silicon determination in water-in-oil-in-water emulsions used for silicon supplementations in food by high-resolution continuum source flame atomic absorption spectrometry
    Gomez-Nieto, Beatriz
    Jesus Gismera, Ma
    Teresa Sevilla, Ma
    Cofrades, Susana
    Freire, Maria
    Procopio, Jesus R.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 148 : 44 - 50
  • [39] Direct determination of copper and zinc in alcoholic and non-alcoholic drinks using high-resolution continuum source flame atomic absorption spectrometry and internal standardization
    Fernandez-Lopez, Laura
    Gomez-Nieto, Beatriz
    Jesus Gismera, W.
    Teresa Sevilla, Ma
    Procopio, Jesus R.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 147 : 21 - 27
  • [40] DETERMINATION OF SILICON IN LUBRICANT OIL BY HIGH-RESOLUTION CONTINUUM SOURCE FLAME ATOMIC ABSORPTION SPECTROMETRY USING LEAST-SQUARE BACKGROUND CORRECTION AND INTERNAL STANDARDIZATION
    Raposo, Jorge Luiz, Jr.
    Oliveira, Silvana Ruella
    Gomes Neto, Jose Anchieta
    Nobrega, Joaquim Araujo
    Jones, Bradley Todd
    ANALYTICAL LETTERS, 2011, 44 (12) : 2150 - 2161