Determining the Total Ozone Column from Spectral Measurements of IKFS-2 in 2015-2022

被引:0
|
作者
Polyakov, A. V. [1 ]
Kriukovskikh, E. P. [1 ]
Virolainen, Ya. A. [1 ]
Nerobelov, G. M. [1 ,2 ,3 ]
Kozlov, D. A. [4 ]
Timofeyev, Yu. M. [1 ]
机构
[1] St Petersburg Univ, St Petersburg 199034, Russia
[2] Russian Acad Sci, Sci Res Ctr Ecol Safety, St Petersburg 187110, Russia
[3] Russian State Hydrometeorol Univ, St Petersburg 195196, Russia
[4] Keldysh Res Ctr, Moscow 125438, Russia
关键词
remote sensing of the atmosphere; atmospheric ozone; IKFS-2; ozone total column; ATMOSPHERIC COMPOSITION; SATELLITE; VALIDATION;
D O I
10.1134/S0001433824700713
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
The results of determining the ozone total column (OTC) from the spectra of the outgoing thermal infrared radiation measured by the IKFS-2 instrument from the Meteor-M No. 2 spacecraft during 8 years of measurements are presented. The previously developed technique for the interpretation of spectral measurements made in 2015-2020 with a swath width (SW) of 1000 km is applied to the measurements in 2021-2022 with a SW of 1500 km. It is shown that the increase in the differences between the IKFS-2 data and the results of independent measurements is caused not by the expansion of the OTC variability statistics, but by the increase in the range of scanning angle variation. After a finalization of the technique for the measurements with a 1500-km SW, a comparison with independent data showed that the standard deviations of differences with the results of ground and satellite measurements for all 8 years do not exceed 3% and did not increase compared to the first 6 years of measurements. To analyze the results in the polar regions, the OTC values obtained from the IKFS-2 spectra are compared with the ozonesonde data, which are performed continuously throughout the year, including the polar night. A good qualitative agreement of the IKFS-2 data and ozone sounding data, including winter-spring periods of extreme OTC decrease at high latitudes of both hemispheres, is shown. The standard deviations of the differences between the IKFS-2 data and the OTC values from ozone sounding data were from 5.3 to 11% (17-33 DU) for different stations, or on average for all stations 7.9%, which is consistent with the uncertainty of the estimates of the integrated ozone content in the vertical column from ozonesonde data.
引用
收藏
页码:689 / 698
页数:10
相关论文
共 50 条
  • [41] The Differential Spectroscopy Technique DOAS in the Problem of Determining the Total Ozone Content from Measurements of Ground-Based UV Spectrometer UFOS
    Ionov, D., V
    Privalov, V., I
    ATMOSPHERIC AND OCEANIC OPTICS, 2022, 35 (01) : 1 - 7
  • [42] The Differential Spectroscopy Technique DOAS in the Problem of Determining the Total Ozone Content from Measurements of Ground-Based UV Spectrometer UFOS
    D. V. Ionov
    V. I. Privalov
    Atmospheric and Oceanic Optics, 2022, 35 : 1 - 7
  • [43] Comparison of total ozone column observations from space-borne Ozone Monitoring Instrument with ground-based Dobson Ozone Spectrophotometer measurements at an urban location in Indo-Gangetic Basin
    Ul-Haq, Zia
    Ramzan, Zertasha
    Tariq, Salman
    Batool, Syeda Adila
    Ali, Muhammad
    Sami, Javed
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 2018, 39 (02) : 544 - 564
  • [44] Retrievals of aerosol optical depth and total column ozone from Ultraviolet Multifilter Rotating Shadowband Radiometer measurements based on an optimal estimation technique
    Chaoshun LIU
    Maosi CHEN
    Runhe SHI
    Wei GAO
    Frontiers of Earth Science, 2014, 8 (04) : 610 - 624
  • [45] HDO and H2O total column retrievals from TROPOMI shortwave infrared measurements
    Scheepmaker, Remco A.
    aan de Brugh, Joost
    Hu, Haili
    Borsdorff, Tobias
    Frankenberg, Christian
    Risi, Camille
    Hasekamp, Otto
    Aben, Ilse
    Landgraf, Jochen
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2016, 9 (08) : 3921 - 3937
  • [46] Retrievals of aerosol optical depth and total column ozone from Ultraviolet Multifilter Rotating Shadowband Radiometer measurements based on an optimal estimation technique
    Chaoshun Liu
    Maosi Chen
    Runhe Shi
    Wei Gao
    Frontiers of Earth Science, 2014, 8 : 610 - 624
  • [47] Comparison of total column ozone data from ground-based MFRSR measurements taken in the southern US region with OMI satellite retrievals
    Williams, Quinton L.
    Reddy, Remata S.
    Liu, Heping
    Benjamin, Markeitta S.
    Lu, Duanjun
    Greene, Kantave M.
    GEOPHYSICAL RESEARCH LETTERS, 2008, 35 (20)
  • [48] Retrievals of aerosol optical depth and total column ozone from Ultraviolet Multifilter Rotating Shadowband Radiometer measurements based on an optimal estimation technique
    Liu, Chaoshun
    Chen, Maosi
    Shi, Runhe
    Gao, Wei
    FRONTIERS OF EARTH SCIENCE, 2014, 8 (04) : 610 - 624
  • [49] Comparison of measurements of total ozone by the GOME (ERS-2) spectrometer with data from the Russian ozonometric network
    Ionov, DV
    Timofeev, YM
    Ionov, VV
    Shalamyanskii, AM
    Johannessen, OM
    Burrows, JP
    EARTH OBSERVATION AND REMOTE SENSING, 2001, 16 (04): : 527 - 539
  • [50] Comparison of total ozone measurements by GOME spectrometer (ERS-2) with data from the Russian ozonometric network
    Ionov, DV
    Timofeyev, YM
    Ionov, VV
    Shalamyansky, AM
    Johannessen, OM
    Burrows, JP
    27TH INTERNATIONAL SYMPOSIUM ON REMOTE SENSING OF ENVIRONMENT, PROCEEDINGS: INFORMATION FOR SUSTAINABILITY, 1998, : 274 - 277