Determining the Total Ozone Column from Spectral Measurements of IKFS-2 in 2015-2022

被引:0
|
作者
Polyakov, A. V. [1 ]
Kriukovskikh, E. P. [1 ]
Virolainen, Ya. A. [1 ]
Nerobelov, G. M. [1 ,2 ,3 ]
Kozlov, D. A. [4 ]
Timofeyev, Yu. M. [1 ]
机构
[1] St Petersburg Univ, St Petersburg 199034, Russia
[2] Russian Acad Sci, Sci Res Ctr Ecol Safety, St Petersburg 187110, Russia
[3] Russian State Hydrometeorol Univ, St Petersburg 195196, Russia
[4] Keldysh Res Ctr, Moscow 125438, Russia
关键词
remote sensing of the atmosphere; atmospheric ozone; IKFS-2; ozone total column; ATMOSPHERIC COMPOSITION; SATELLITE; VALIDATION;
D O I
10.1134/S0001433824700713
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
The results of determining the ozone total column (OTC) from the spectra of the outgoing thermal infrared radiation measured by the IKFS-2 instrument from the Meteor-M No. 2 spacecraft during 8 years of measurements are presented. The previously developed technique for the interpretation of spectral measurements made in 2015-2020 with a swath width (SW) of 1000 km is applied to the measurements in 2021-2022 with a SW of 1500 km. It is shown that the increase in the differences between the IKFS-2 data and the results of independent measurements is caused not by the expansion of the OTC variability statistics, but by the increase in the range of scanning angle variation. After a finalization of the technique for the measurements with a 1500-km SW, a comparison with independent data showed that the standard deviations of differences with the results of ground and satellite measurements for all 8 years do not exceed 3% and did not increase compared to the first 6 years of measurements. To analyze the results in the polar regions, the OTC values obtained from the IKFS-2 spectra are compared with the ozonesonde data, which are performed continuously throughout the year, including the polar night. A good qualitative agreement of the IKFS-2 data and ozone sounding data, including winter-spring periods of extreme OTC decrease at high latitudes of both hemispheres, is shown. The standard deviations of the differences between the IKFS-2 data and the OTC values from ozone sounding data were from 5.3 to 11% (17-33 DU) for different stations, or on average for all stations 7.9%, which is consistent with the uncertainty of the estimates of the integrated ozone content in the vertical column from ozonesonde data.
引用
收藏
页码:689 / 698
页数:10
相关论文
共 50 条
  • [31] DETERMINING OZONE NUMBER DENSITY DISTRIBUTION FROM OAO-2 STELLAR OCCULTATION MEASUREMENTS
    ROSENBER.GV
    SEMENOV, AI
    SHEFOV, NN
    PLANETARY AND SPACE SCIENCE, 1974, 22 (10) : 1455 - 1456
  • [32] DETERMINING OZONE NUMBER DENSITY DISTRIBUTION FROM OAO-2 STELLAR OCCULTATION MEASUREMENTS
    ROBLE, RG
    HAYS, PB
    PLANETARY AND SPACE SCIENCE, 1974, 22 (09) : 1337 - 1340
  • [33] ACCURACY OF TOTAL OZONE RETRIEVAL FROM NOAA SBUTJ/2 MEASUREMENTS - IMPACT OF INSTRUMENT PERFORMANCE
    AHMAD, Z
    DELAND, MT
    CEBULA, RP
    WEISS, H
    WELLEMEYER, CG
    PLANET, WG
    LIENESCH, JH
    BOWMAN, HD
    MILLER, AJ
    NAGATANI, RM
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1994, 99 (D11) : 22975 - 22984
  • [34] Total ozone column from Ozone Mapping and Profiler Suite Nadir Mapper (OMPS-NM) measurements using the broadband weighting function fitting approach (WFFA)
    Orfanoz-Cheuquelaf, Andrea
    Rozanov, Alexei
    Weber, Mark
    Arosio, Carlo
    Ladstaetter-Weissenmayer, Annette
    Burrows, John P.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2021, 14 (08) : 5771 - 5789
  • [35] Retrieval of total column and surface NO2 from Pandora zenith-sky measurements
    Zhao, Xiaoyi
    Griffin, Debora
    Fioletov, Vitali
    McLinden, Chris
    Dayies, Jonathan
    Ogyu, Akira
    Lee, Sum Chi
    Lupu, Alexandru
    Moran, Michael D.
    Cede, Alexander
    Tiefengraber, Martin
    Mueller, Moritz
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2019, 19 (16) : 10619 - 10642
  • [36] TOTAL COLUMN RETRIEVAL OF SO2 AND HCHO FROM SENTINEL-4 MEASUREMENTS
    van Gent, Jeroen
    Theys, Nicolas
    Yu, Huan
    De Smedt, Isabelle
    Lerot, Christophe
    Van Roozendael, Michel
    IGARSS 2020 - 2020 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, 2020, : 6039 - 6042
  • [37] Total ozone column derived from GOME and SCIAMACHY using KNMI retrieval algorithms: Validation against Brewer measurements at the Iberian Peninsula
    Anton, M.
    Kroon, M.
    Lopez, M.
    Vilaplana, J. M.
    Banon, M.
    van der A, R.
    Veefkind, J. P.
    Stammes, P.
    Alados-Arboledas, L.
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2011, 116
  • [38] AEROSOL FIELD INFLUENCE ON THE RETRIEVAL OF THE OZONE VERTICAL COLUMN DENSITIES FROM PANDORA 2S MEASUREMENTS
    Dandocsi, Alexandru
    Nemuc, Anca
    Nicolae, Doina
    Belegante, Livio
    Cede, Alexander
    Tiefengraber, Martin
    29TH INTERNATIONAL LASER RADAR CONFERENCE (ILRC 29), 2020, 237
  • [39] Mapping the CO2 total column retrieval performance from shortwave infrared measurements: synthetic impacts of the spectral resolution, signal-to-noise ratio, and spectral band selection
    Dogniaux, Matthieu
    Crevoisier, Cyril
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2024, 17 (17) : 5373 - 5396
  • [40] High precision, absolute total column ozone measurements from the Pandora spectrometer system: Comparisons with data from a Brewer double monochromator and Aura OMI
    Tzortziou, Maria
    Herman, Jay R.
    Cede, Alexander
    Abuhassan, Nader
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2012, 117