Determining the Total Ozone Column from Spectral Measurements of IKFS-2 in 2015-2022

被引:0
|
作者
Polyakov, A. V. [1 ]
Kriukovskikh, E. P. [1 ]
Virolainen, Ya. A. [1 ]
Nerobelov, G. M. [1 ,2 ,3 ]
Kozlov, D. A. [4 ]
Timofeyev, Yu. M. [1 ]
机构
[1] St Petersburg Univ, St Petersburg 199034, Russia
[2] Russian Acad Sci, Sci Res Ctr Ecol Safety, St Petersburg 187110, Russia
[3] Russian State Hydrometeorol Univ, St Petersburg 195196, Russia
[4] Keldysh Res Ctr, Moscow 125438, Russia
关键词
remote sensing of the atmosphere; atmospheric ozone; IKFS-2; ozone total column; ATMOSPHERIC COMPOSITION; SATELLITE; VALIDATION;
D O I
10.1134/S0001433824700713
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
The results of determining the ozone total column (OTC) from the spectra of the outgoing thermal infrared radiation measured by the IKFS-2 instrument from the Meteor-M No. 2 spacecraft during 8 years of measurements are presented. The previously developed technique for the interpretation of spectral measurements made in 2015-2020 with a swath width (SW) of 1000 km is applied to the measurements in 2021-2022 with a SW of 1500 km. It is shown that the increase in the differences between the IKFS-2 data and the results of independent measurements is caused not by the expansion of the OTC variability statistics, but by the increase in the range of scanning angle variation. After a finalization of the technique for the measurements with a 1500-km SW, a comparison with independent data showed that the standard deviations of differences with the results of ground and satellite measurements for all 8 years do not exceed 3% and did not increase compared to the first 6 years of measurements. To analyze the results in the polar regions, the OTC values obtained from the IKFS-2 spectra are compared with the ozonesonde data, which are performed continuously throughout the year, including the polar night. A good qualitative agreement of the IKFS-2 data and ozone sounding data, including winter-spring periods of extreme OTC decrease at high latitudes of both hemispheres, is shown. The standard deviations of the differences between the IKFS-2 data and the OTC values from ozone sounding data were from 5.3 to 11% (17-33 DU) for different stations, or on average for all stations 7.9%, which is consistent with the uncertainty of the estimates of the integrated ozone content in the vertical column from ozonesonde data.
引用
收藏
页码:689 / 698
页数:10
相关论文
共 50 条
  • [21] Validation of total ozone column derived from OMPS using ground-based spectroradiometer measurements
    Chen, Zuoqi
    Yu, Bailang
    Huang, Yan
    Hu, Yingjie
    Lin, Hao
    Wu, Jianping
    REMOTE SENSING LETTERS, 2013, 4 (10) : 937 - 945
  • [22] SPECTRAL MEASUREMENTS OF SOLAR UVB RADIATION AND ITS RELATIONS TO TOTAL OZONE, SO2, AND CLOUDS
    BAIS, AF
    ZEREFOS, CS
    MELETI, C
    ZIOMAS, IC
    TOURPALI, K
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1993, 98 (D3) : 5199 - 5204
  • [23] Total ozone column retrieval from UV-MFRSR irradiance measurements: Evaluation at Mauna Loa station
    Zempila, Melina Maria
    Fragkos, Konstantinos
    Davis, John
    Sun, Zhibin
    Chen, Maosi
    Gao, Wei
    REMOTE SENSING AND MODELING OF ECOSYSTEMS FOR SUSTAINABILITY XIV, 2017, 10405
  • [24] Seven years of IASI ozone retrievals from FORLI: validation with independent total column and vertical profile measurements
    Boynard, Anne
    Hurtmans, Daniel
    Koukouli, Mariliza E.
    Goutail, Florence
    Bureau, Jerome
    Safieddine, Sarah
    Lerot, Christophe
    Hadji-Lazaro, Juliette
    Wespes, Catherine
    Pommereau, Jean-Pierre
    Pazmino, Andrea
    Zyrichidou, Irene
    Balis, Dimitris
    Barbe, Alain
    Mikhailenko, Semen N.
    Loyola, Diego
    Valks, Pieter
    Van Roozendael, Michel
    Coheur, Pierre-Francois
    Clerbaux, Cathy
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2016, 9 (09) : 4327 - 4353
  • [25] Comparison of total column ozone measurements obtained from a global UV spectroradiometer with those from a Dobson spectrophotometer at Melbourne Australia
    Anderson, D
    ULTRAVIOLET GROUND- AND SPACE-BASED MEASUREMENTS, MODELS AND EFFECTS III, 2003, 5156 : 311 - 315
  • [26] A global surface CO 2 flux dataset (2015-2022) inferred from OCO-2 retrievals using the GONGGA inversion system
    Jin, Zhe
    Tian, Xiangjun
    Wang, Yilong
    Zhang, Hongqin
    Zhao, Min
    Wang, Tao
    Ding, Jinzhi
    Piao, Shilong
    EARTH SYSTEM SCIENCE DATA, 2024, 16 (06) : 2857 - 2876
  • [27] Temporal and spatial variability of total ozone column using TOMS satellite observations and comparison with measurements from the Dobson network
    Ogunjobi, K. O.
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 2011, 32 (21) : 6731 - 6747
  • [28] Machine Learning-Based Retrieval of Total Ozone Column Amount and Cloud Optical Depth from Irradiance Measurements
    Sztipanov, Milos
    Krizsan, Levente
    Li, Wei
    Stamnes, Jakob J.
    Svendby, Tove
    Stamnes, Knut
    ATMOSPHERE, 2024, 15 (09)
  • [29] Intercomparison of total column ozone data from the Pandora spectrophotometer with Dobson, Brewer, and OMI measurements over Seoul, Korea
    Kim, Jiyoung
    Kim, Jhoon
    Cho, Hi-Ku
    Herman, Jay
    Park, Sang Seo
    Lim, Hyun Kwang
    Kim, Jae-Hwan
    Miyagawa, Koji
    Lee, Yun Gon
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2017, 10 (10) : 3661 - 3676
  • [30] The direct fitting approach for total ozone column retrievals: a sensitivity study on GOME-2/MetOp-A measurements
    Wassmann, A.
    Borsdorff, T.
    aan de Brugh, J. M. J.
    Hasekamp, O. P.
    Aben, I.
    Landgraf, J.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2015, 8 (10) : 4429 - 4451