Fully 4D-Printed Near-Infrared-Actuated Lab-on-Valve Solid-Phase Extraction Devices

被引:0
|
作者
Kuo, Chia-Hsun [1 ]
Su, Cheng-Kuan [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402202, Taiwan
关键词
TRACE-ELEMENTS; SEQUENTIAL-INJECTION; ANALYTICAL-CHEMISTRY; BILAYER ACTUATORS; FLOW-INJECTION; LIGHT-DRIVEN; USEFUL TOOL; ICP-MS; PRECONCENTRATION; MICROVALVE;
D O I
10.1021/acs.analchem.4c05363
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Four-dimensional printing (4DP) technologies can expand the functionality of stimuli-responsive devices to enable the integration of multiple stimuli-responsive parts into a compact device. Herein, we used digital light processing three-dimensional printing technique, flexible photocurable resins, and photocurable resins of the temperature-responsive hydrogels comprising N-isopropylacrylamide (NIPAM), N,N '-methylenebis(acrylamide) (MBA), and graphene for 4DP of a lab-on-valve (LOV) solid-phase extraction (SPE) device. This device featured flow manifolds and a monolithic packing connected by four near-infrared (NIR)-actuated temperature-responsive switching valves composed of a poly(NIPAM/MBA) (PNM) ball pushing a flexible membrane. NIR irradiation caused the deswelling of the PNM ball [temperature > volume phase transition temperature (VPTT) of the hydrogel], and the valve was opened to switch the flow direction. The termination of this irradiation caused the swelling of the PNM ball (temperature < VPTT of the hydrogel) to close the valve and thus recover the original flow direction to achieve the automatic NIR-actuated fluid control. The optimized 4D-printed NIR-actuated LOV-SPE device enabled a fully automatic SPE scheme coupled with inductively coupled plasma mass spectrometry for the determination of Mn, Co, Ni, Cu, Zn, Cd, and Pb ions (detection limits = 0.1,6.8 ng L-1). The reliability of this analytical method was validated by determining the metal ions in the four reference materials (CASS-6, SLRS-5, 1643f, and Trace Elements Urine L-2) and environmental water and human urine samples. Our results demonstrated the capability and applicability of 4DP technologies for advancing the automation of LOV-SPE schemes and related analytical methods.
引用
收藏
页码:1281 / 1290
页数:10
相关论文
共 50 条
  • [41] 3D hollow porous CdFe2O4 microspheres as viable materials for magnetic solid-phase extraction of azo colorants
    Zhang, Danfeng
    Zhang, Lei
    Liu, Tong
    MICROCHIMICA ACTA, 2018, 185 (05)
  • [42] Fully automated lab-on-valve-multisyringe flow injection analysis-ICP-MS system: an effective tool for fast, sensitive and selective determination of thorium and uranium at environmental levels exploiting solid phase extraction
    Avivar, Jessica
    Ferrer, Laura
    Casas, Montserrat
    Cerda, Victor
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (02) : 327 - 334
  • [43] Development of a fully automated sequential injection solid-phase extraction procedure coupled to liquid chromatography to determine free 2-hydroxy-4-methoxybenzophenone and 2-hydroxy-4-methoxybenzophenone-5-sulphonic acid in human urine
    Leon, Zacarias
    Chisvert, Alberto
    Balaguer, Angel
    Salvador, Amparo
    ANALYTICA CHIMICA ACTA, 2010, 664 (02) : 178 - 184
  • [44] Determination of N-(trans-4-isopropylcyclohexylcarbonyl)-D-phenylalanine in human plasma by solid-phase extraction and column-switching high-performance liquid chromatography with ultraviolet detection
    Ono, I
    Matsuda, K
    Kanno, S
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 678 (02): : 384 - 387
  • [45] 3D flower-liked Fe3O4/C for highly sensitive magnetic dispersive solid-phase extraction of four trace non-steroidal anti-inflammatory drugs
    Xu, Xu
    Feng, Xue
    Liu, Zhen
    Xue, Shan
    Zhang, Lei
    MICROCHIMICA ACTA, 2021, 188 (02)
  • [46] 3D flower-liked Fe3O4/C for highly sensitive magnetic dispersive solid-phase extraction of four trace non-steroidal anti-inflammatory drugs
    Xu Xu
    Xue Feng
    Zhen Liu
    Shan Xue
    Lei Zhang
    Microchimica Acta, 2021, 188
  • [47] 3-D graphene-supported mesoporous SiO2@Fe3O4 composites for the analysis of pesticides in aqueous samples by magnetic solid-phase extraction with high-performance liquid chromatography
    Wang, Xuemei
    Wang, Huan
    Lu, Muxin
    Ma, Xiaomin
    Huang, Pengfei
    Lu, Xiaoquan
    Du, Xinzhen
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (09) : 1734 - 1741
  • [48] Modular Point-of-Need Tropane Alkaloid Detection at Regulatory Levels: Combining Solid-Liquid Extraction from Buckwheat with a Paper-Immobilized Liquid-Phase Microextraction and Immuno-Detection in Interconnectable 3D-Printed Devices
    Lemmink, Ids B.
    Willemsen, Linda
    Beij, Erik
    Bovee, Toine F. H.
    Zuilhof, Han
    Salentijn, Gert I. J.
    ANALYTICAL CHEMISTRY, 2024, 96 (41) : 16462 - 16468
  • [49] 2D MOF@Fe3O4@rGO as magnetic solid-phase extraction and supercritical fluids chromatography-tandem mass spectrometry quantification of strigolactones stereoisomers in rice (Oryza sativa L.)
    Deng, Xunzhi
    Li, Qinyao
    Lu, Jing
    Liu, Yilin
    Li, Haiou
    Liao, Ze
    Huang, Gang
    Xiao, Langtao
    Luo, Zhoufei
    FOOD CHEMISTRY, 2025, 479
  • [50] ONLINE FULLY AUTOMATED SOLID-PHASE EXTRACTION LIQUID-CHROMATOGRAPHY ANALYSIS OF 1,2-DIHYDRO-4-(1,2-DIHYDRO-2-OXO-1-PYRIDYL)-2,2-DIMETHYL-1-OXONAPHTHALENE-6-CARBONITRILE (UR-8225), A NEW POTASSIUM CHANNEL OPENER, IN PLASMA SAMPLES
    NIETO, C
    RAMIS, J
    CONTE, L
    FERNANDEZ, JM
    FORN, J
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 661 (02): : 319 - 325