Fully 4D-Printed Near-Infrared-Actuated Lab-on-Valve Solid-Phase Extraction Devices

被引:0
|
作者
Kuo, Chia-Hsun [1 ]
Su, Cheng-Kuan [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402202, Taiwan
关键词
TRACE-ELEMENTS; SEQUENTIAL-INJECTION; ANALYTICAL-CHEMISTRY; BILAYER ACTUATORS; FLOW-INJECTION; LIGHT-DRIVEN; USEFUL TOOL; ICP-MS; PRECONCENTRATION; MICROVALVE;
D O I
10.1021/acs.analchem.4c05363
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Four-dimensional printing (4DP) technologies can expand the functionality of stimuli-responsive devices to enable the integration of multiple stimuli-responsive parts into a compact device. Herein, we used digital light processing three-dimensional printing technique, flexible photocurable resins, and photocurable resins of the temperature-responsive hydrogels comprising N-isopropylacrylamide (NIPAM), N,N '-methylenebis(acrylamide) (MBA), and graphene for 4DP of a lab-on-valve (LOV) solid-phase extraction (SPE) device. This device featured flow manifolds and a monolithic packing connected by four near-infrared (NIR)-actuated temperature-responsive switching valves composed of a poly(NIPAM/MBA) (PNM) ball pushing a flexible membrane. NIR irradiation caused the deswelling of the PNM ball [temperature > volume phase transition temperature (VPTT) of the hydrogel], and the valve was opened to switch the flow direction. The termination of this irradiation caused the swelling of the PNM ball (temperature < VPTT of the hydrogel) to close the valve and thus recover the original flow direction to achieve the automatic NIR-actuated fluid control. The optimized 4D-printed NIR-actuated LOV-SPE device enabled a fully automatic SPE scheme coupled with inductively coupled plasma mass spectrometry for the determination of Mn, Co, Ni, Cu, Zn, Cd, and Pb ions (detection limits = 0.1,6.8 ng L-1). The reliability of this analytical method was validated by determining the metal ions in the four reference materials (CASS-6, SLRS-5, 1643f, and Trace Elements Urine L-2) and environmental water and human urine samples. Our results demonstrated the capability and applicability of 4DP technologies for advancing the automation of LOV-SPE schemes and related analytical methods.
引用
收藏
页码:1281 / 1290
页数:10
相关论文
共 50 条
  • [31] On-line renewable solid-phase extraction hyphenated to liquid chromatography for the determination of UV filters using bead injection and multisyringe-lab-on-valve approach
    Oliveira, Hugo M.
    Segundo, Marcela A.
    Lima, Jose L. F. C.
    Miro, Manuel
    Cerda, Victor
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (22) : 3575 - 3582
  • [32] 3D-Printed Column with Porous Monolithic Packing for Online Solid-Phase Extraction of Multiple Trace Metals in Environmental Water Samples
    Su, Cheng-Kuan
    Lin, Jou-Yu
    ANALYTICAL CHEMISTRY, 2020, 92 (14) : 9640 - 9648
  • [33] Atrazine and 2, 4-D Determination in Corn Samples Using Microwave Assisted Extraction and On-line Solid-phase Extraction Coupled to Liquid Chromatography
    Susana Santos-Hernandez, Ana
    Hinojosa-Reyes, Laura
    del Carmen Saenz-Tavera, Isabel
    Hernandez-Ramirez, Aracely
    Luis Guzman-Mar, Jorge
    JOURNAL OF THE MEXICAN CHEMICAL SOCIETY, 2018, 62 (02) : 282 - 294
  • [34] SOLID-PHASE EXTRACTION PROTOCOL FOR ISOLATING RETINOL-D(4) AND RETINOL FROM PLASMA FOR PARALLEL-PROCESSING FOR EPIDEMIOLOGIC STUDIES
    DUEKER, SR
    LUNETTA, JM
    JONES, AD
    CLIFFORD, AJ
    CLINICAL CHEMISTRY, 1993, 39 (11) : 2318 - 2322
  • [35] A PARALLEL PROCESSING SOLID-PHASE EXTRACTION PROTOCOL FOR ISOLATING RETINOL-D4 AND RETINOL FROM HUMAN PLASMA FOR EPIDEMIOLOGIC STUDIES
    DUEKER, SR
    LUNETTA, JM
    JONES, AD
    CLIFFORD, AJ
    FASEB JOURNAL, 1993, 7 (03): : A304 - A304
  • [36] 3D printed device coated with solid-phase extraction resin for the on-site extraction of seven sulfonamides from environmental water samples preceding HPLC-DAD analysis
    Barzallo, Diego
    Palacio, Edwin
    March, Juan
    Ferrer, Laura
    MICROCHEMICAL JOURNAL, 2023, 190
  • [37] 3D printed microplasma optical emission spectrometry coupled with ZIF-8 based dispersive solid-phase extraction for field analysis of waterborne arsenic
    Yang, Jiahui
    Lin, Yao
    Wang, Xi
    Li, Yuanyuan
    Deng, Yurong
    Zheng, Chengbin
    ANALYTICA CHIMICA ACTA, 2024, 1330
  • [38] 3D printed device including disk-based solid-phase extraction for the automated speciation of iron using the multisyringe flow injection analysis technique
    Calderilla, Carlos
    Maya, Fernando
    Cerda, Victor
    Leal, Luz O.
    TALANTA, 2017, 175 : 463 - 469
  • [39] Preconcentration and speciation analysis of mercury: 3D printed metal scavenger-based solid-phase extraction followed by analysis with inductively coupled plasma mass spectrometry
    Kulomaki, Suvi
    Lahtinen, Elmeri
    Peramaki, Siiri
    Vaisanen, Ari
    TALANTA, 2022, 240
  • [40] 3D hollow porous CdFe2O4 microspheres as viable materials for magnetic solid-phase extraction of azo colorants
    Danfeng Zhang
    Lei Zhang
    Tong Liu
    Microchimica Acta, 2018, 185