Fully 4D-Printed Near-Infrared-Actuated Lab-on-Valve Solid-Phase Extraction Devices

被引:0
|
作者
Kuo, Chia-Hsun [1 ]
Su, Cheng-Kuan [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402202, Taiwan
关键词
TRACE-ELEMENTS; SEQUENTIAL-INJECTION; ANALYTICAL-CHEMISTRY; BILAYER ACTUATORS; FLOW-INJECTION; LIGHT-DRIVEN; USEFUL TOOL; ICP-MS; PRECONCENTRATION; MICROVALVE;
D O I
10.1021/acs.analchem.4c05363
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Four-dimensional printing (4DP) technologies can expand the functionality of stimuli-responsive devices to enable the integration of multiple stimuli-responsive parts into a compact device. Herein, we used digital light processing three-dimensional printing technique, flexible photocurable resins, and photocurable resins of the temperature-responsive hydrogels comprising N-isopropylacrylamide (NIPAM), N,N '-methylenebis(acrylamide) (MBA), and graphene for 4DP of a lab-on-valve (LOV) solid-phase extraction (SPE) device. This device featured flow manifolds and a monolithic packing connected by four near-infrared (NIR)-actuated temperature-responsive switching valves composed of a poly(NIPAM/MBA) (PNM) ball pushing a flexible membrane. NIR irradiation caused the deswelling of the PNM ball [temperature > volume phase transition temperature (VPTT) of the hydrogel], and the valve was opened to switch the flow direction. The termination of this irradiation caused the swelling of the PNM ball (temperature < VPTT of the hydrogel) to close the valve and thus recover the original flow direction to achieve the automatic NIR-actuated fluid control. The optimized 4D-printed NIR-actuated LOV-SPE device enabled a fully automatic SPE scheme coupled with inductively coupled plasma mass spectrometry for the determination of Mn, Co, Ni, Cu, Zn, Cd, and Pb ions (detection limits = 0.1,6.8 ng L-1). The reliability of this analytical method was validated by determining the metal ions in the four reference materials (CASS-6, SLRS-5, 1643f, and Trace Elements Urine L-2) and environmental water and human urine samples. Our results demonstrated the capability and applicability of 4DP technologies for advancing the automation of LOV-SPE schemes and related analytical methods.
引用
收藏
页码:1281 / 1290
页数:10
相关论文
共 50 条
  • [21] Determination of salivary cotinine through solid phase extraction using a bead-injection lab-on-valve approach hyphenated to hydrophilic interaction liquid chromatography
    Ramdzan, Adlin N.
    Barreiros, Luisa
    Almeida, M. Ines G. S.
    Kolev, Spas D.
    Segundo, Marcela A.
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1429 : 284 - 291
  • [22] 3D printed solid-phase extraction sorbents for removal of volatile organic compounds from water
    Lagalante, Luke A.
    Lagalante, Ayden J.
    Lagalante, Anthony F.
    JOURNAL OF WATER PROCESS ENGINEERING, 2020, 35
  • [23] 3D-printed thermally expanded monolithic foam for solid-phase extraction of multiple trace metals
    Cheng, Yu-Hsuan
    Su, Cheng-Kuan
    MICROCHIMICA ACTA, 2024, 191 (10)
  • [24] Automatic and renewable micro-solid-phase extraction based on bead injection lab-on-valve system for determination of tranexamic acid in urine by UHPLC coupled with tandem mass spectrometry
    Fernandes, Sara R.
    Barreiros, Luisa
    Sa, Paula
    Miro, Manuel
    Segundo, Marcela A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (01) : 649 - 659
  • [25] 3D printed spinning cup-shaped device for immunoaffinity solid-phase extraction of diclofenac in wastewaters
    Enrique Javier Carrasco-Correa
    José Manuel Herrero-Martínez
    Ernesto Francisco Simó-Alfonso
    Dietmar Knopp
    Manuel Miró
    Microchimica Acta, 2022, 189
  • [26] 3D printed spinning cup-shaped device for immunoaffinity solid-phase extraction of diclofenac in wastewaters
    Javier Carrasco-Correa, Enrique
    Manuel Herrero-Martinez, Jose
    Francisco Simo-Alfonso, Ernesto
    Knopp, Dietmar
    Miro, Manuel
    MICROCHIMICA ACTA, 2022, 189 (05)
  • [27] Automatic and renewable micro-solid-phase extraction based on bead injection lab-on-valve system for determination of tranexamic acid in urine by UHPLC coupled with tandem mass spectrometry
    Sara R. Fernandes
    Luisa Barreiros
    Paula Sá
    Manuel Miró
    Marcela A. Segundo
    Analytical and Bioanalytical Chemistry, 2022, 414 : 649 - 659
  • [28] Monitoring the reaction process of Fmoc-D-Ala-OH in solid-phase synthesis of peptides with near infrared spectroscopy
    Wang, Kaijun
    Wang, Xiao
    Zhang, Wenting
    Zhang, Weibing
    Du, Yiping
    Xu, Min
    Wang, Liangyou
    Song, Liang
    Xu, Huiting
    INFRARED PHYSICS & TECHNOLOGY, 2024, 136
  • [29] A novel gravity valve and its application in a 3D printed centrifugal fluidic-system for solid phase extraction (SPE)
    Zhang, Yong
    Xiang, Jiwen
    Wang, Yunxia
    Qiao, Zheng
    Wang, Wanjun
    MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS XVIII, 2020, 11235
  • [30] Plant pathogen detection on a lab-on-a-disc using solid-phase extraction and isothermal nucleic acid amplification enabled by digital pulse-actuated dissolvable film valves
    Mishra, Rohit
    Julius, Lourdes AN.
    Condon, Jack
    Pavelskopfa, Patricija
    Early, Philip L.
    Dorrian, Matthew
    Mrvova, Katarina
    Henihan, Grace
    Mangwanya, Faith
    Dreo, Tanya
    Ducree, Jens
    Macdonald, Niall P.
    Schoen, Cor
    Kinahan, David J.
    ANALYTICA CHIMICA ACTA, 2023, 1258