Fully 4D-Printed Near-Infrared-Actuated Lab-on-Valve Solid-Phase Extraction Devices

被引:0
|
作者
Kuo, Chia-Hsun [1 ]
Su, Cheng-Kuan [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402202, Taiwan
关键词
TRACE-ELEMENTS; SEQUENTIAL-INJECTION; ANALYTICAL-CHEMISTRY; BILAYER ACTUATORS; FLOW-INJECTION; LIGHT-DRIVEN; USEFUL TOOL; ICP-MS; PRECONCENTRATION; MICROVALVE;
D O I
10.1021/acs.analchem.4c05363
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Four-dimensional printing (4DP) technologies can expand the functionality of stimuli-responsive devices to enable the integration of multiple stimuli-responsive parts into a compact device. Herein, we used digital light processing three-dimensional printing technique, flexible photocurable resins, and photocurable resins of the temperature-responsive hydrogels comprising N-isopropylacrylamide (NIPAM), N,N '-methylenebis(acrylamide) (MBA), and graphene for 4DP of a lab-on-valve (LOV) solid-phase extraction (SPE) device. This device featured flow manifolds and a monolithic packing connected by four near-infrared (NIR)-actuated temperature-responsive switching valves composed of a poly(NIPAM/MBA) (PNM) ball pushing a flexible membrane. NIR irradiation caused the deswelling of the PNM ball [temperature > volume phase transition temperature (VPTT) of the hydrogel], and the valve was opened to switch the flow direction. The termination of this irradiation caused the swelling of the PNM ball (temperature < VPTT of the hydrogel) to close the valve and thus recover the original flow direction to achieve the automatic NIR-actuated fluid control. The optimized 4D-printed NIR-actuated LOV-SPE device enabled a fully automatic SPE scheme coupled with inductively coupled plasma mass spectrometry for the determination of Mn, Co, Ni, Cu, Zn, Cd, and Pb ions (detection limits = 0.1,6.8 ng L-1). The reliability of this analytical method was validated by determining the metal ions in the four reference materials (CASS-6, SLRS-5, 1643f, and Trace Elements Urine L-2) and environmental water and human urine samples. Our results demonstrated the capability and applicability of 4DP technologies for advancing the automation of LOV-SPE schemes and related analytical methods.
引用
收藏
页码:1281 / 1290
页数:10
相关论文
共 50 条
  • [1] 4D-Printed Temperature-Controlled Flow-Actuated Solid-Phase Extraction Devices
    Wu, Chun-Yi
    Chen, Jyun-Ran
    Su, Cheng-Kuan
    ANALYTICAL CHEMISTRY, 2021, 93 (33) : 11497 - 11505
  • [2] 4D-printed programmable sample-/eluent-actuated solid-phase extraction device for trace metal analysis
    Kuo, Chia-Hsun
    Su, Cheng-Kuan
    ANALYTICA CHIMICA ACTA, 2025, 1336
  • [3] Sequential injection lab-on-valve platform as a miniaturisation tool for solid phase extraction
    Vidigal, Susana S. M. P.
    Toth, Ildiko V.
    Rangel, Antonio O. S. S.
    ANALYTICAL METHODS, 2013, 5 (03) : 585 - 597
  • [4] Automated solid-phase extraction hyphenated to voltammetry for the determination of quercetin using magnetic nanoparticles and sequential injection lab-on-valve approach
    Wang, Yang
    Wang, Lu
    Tian, Tian
    Hu, Xiaoya
    Yang, Chun
    Xu, Qin
    ANALYST, 2012, 137 (10) : 2400 - 2405
  • [5] 4D-Printed Elution-Peak-Guided Dual-Responsive Monolithic Packing for the Solid-Phase Extraction of Metal Ions
    Tsai, Wen-Hsiu
    Su, Cheng-Kuan
    ANALYTICAL CHEMISTRY, 2024, 96 (11) : 4469 - 4478
  • [6] Determination of trace zinc in seawater by coupling solid phase extraction and fluorescence detection in the Lab-On-Valve format
    Grand, Maxime M.
    Chocholous, Petr
    Ruzicka, Jarda
    Solich, Petr
    Measures, Christopher I.
    ANALYTICA CHIMICA ACTA, 2016, 923 : 45 - 54
  • [7] Dispersive solid-phase extraction facilitated by newly developed, fully 3D-printed device
    Szynkiewicz, Dagmara
    Georgiev, Pawel
    Ulenberg, Szymon
    Aczek, Tomasz B.
    Belka, Mariusz
    MICROCHEMICAL JOURNAL, 2023, 187
  • [8] Automated on-line renewable solid-phase extraction-liquid chromatography exploiting multisyringe flow injection-bead injection lab-on-valve analysis
    Quintana, JB
    Miró, M
    Estela, JM
    Cerdà, V
    ANALYTICAL CHEMISTRY, 2006, 78 (08) : 2832 - 2840
  • [9] Exploiting automatic on-line renewable molecularly imprinted solid-phase extraction in lab-on-valve format as front end to liquid chromatography: application to the determination of riboflavin in foodstuffs
    Hugo M. Oliveira
    Marcela A. Segundo
    José L. F. C. Lima
    Manuel Miró
    Victor Cerdà
    Analytical and Bioanalytical Chemistry, 2010, 397 : 77 - 86
  • [10] 3D Printed Microfluidic Devices for Integrated Immunoaffinity Extraction, Solid-Phase Extraction, and Fluorescent Labeling of Preterm Birth Biomarkers
    Holladay, James D.
    Berkheimer, Zachary A.
    Haggard, Michael K.
    Nielsen, Jacob B.
    Nordin, Gregory P.
    Woolley, Adam T.
    PRECISION CHEMISTRY, 2025,