Effect of crystalline lens decentration and tilt on visual performance in eyes implanted with bifocal or extended depth of focus intraocular lenses

被引:0
|
作者
Zhang, Yu [1 ,2 ]
Zhang, Jiaqing [1 ]
Liang, Chen [1 ]
Xu, Yifan [1 ,2 ]
Wu, Jiaying [2 ]
Wu, Junming [2 ]
Zhang, Yifan [1 ,2 ]
Jin, Aixia [1 ,2 ]
Tan, Xuhua [1 ]
Luo, Lixia [1 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangdong Prov Key Lab Ophthalmol & Visual Sci, Guangzhou, Peoples R China
[2] Sun Yat Sen Univ Med Sci, Guangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Cataract; Intraocular lens; IOL; Presbyopia-correcting IOL; Decentration; Tilt; RETINAL IMAGE QUALITY; OPTICAL-QUALITY; CONTRAST SENSITIVITY; ABERRATION; PRECISION; VISION;
D O I
10.1186/s12886-025-03884-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo explore the potential of crystalline lens decentration and tilt as indicators for screening cataract patients for presbyopia-correcting intraocular lens (IOL) implantation. MethodsProspective observational study. Patients undergoing phacoemulsification with bifocal (Tecnis ZMB00) or extended depth-of-focus (EDOF) (Tecnis ZXR00) IOL implantation were consecutively enrolled. The decentration and tilt of the crystalline lens and the IOL were quantified through the utilization of swept-source optical coherence tomography (SS-OCT, Casia2). Postoperative visual acuity (VA), contrast sensitivity (CS), objective optical quality, and patient-reported outcomes were assessed at a 3-month follow-up. A LOWESS (LOcally WEighted Scatterplot Smoothing) curve was employed to analyze the changes in VA, CS, and objective optical quality relative to the decentration or tilt of crystalline lenses. A further comparison of visual outcomes was conducted based on the inflection points suggested by the curves. ResultsEighty-seven patients with ZMB00 IOL and 76 patients with ZXR00 IOL were included. Multiple 6-mm internal aberrations showed a nonlinear increase with greater crystalline lens decentration. The inflection points for the steep increase were observed to be 0.28 mm for the bifocal group and 0.35 mm for the EDOF group. Beyond these points, internal aberrations such as coma increased significantly (all P < 0.01). Patient satisfaction decreased (P < 0.01). Moreover, the bifocal group exhibited a decline in spectacle-independence from 98.67% to 83.33% (P = 0.049), along with a reduction in CS (P < 0.05). ConclusionsThe increased decentration of crystalline lenses compromises specific visual quality aspects in eyes implanted with ZMB00 and ZXR00 IOLs, with cut-off values of 0.28 mm and 0.35 mm, respectively.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Visual Performance of a New Extended Depth-of-Focus Intraocular Lens Compared to a Distance-Dominant Diffractive Multifocal Intraocular Lens
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Balducci, Nicole
    Barboni, Piero
    JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (04) : 228 - +
  • [42] Visual outcomes of binocular implantation of a new extended depth of focus intraocular lens
    Sinha, Rajesh
    Sahay, Pranita
    Saxena, Rohit
    Kalra, Nidhi
    Gupta, Vinay
    Titiyal, Jeewan S.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (10) : 2111 - 2116
  • [43] Assessment of refractive methodologies in patients implanted with extended depth of focus intraocular lenses (EDF IOLs)
    Li, Eric
    Vilupuru, Srividhya
    Alarcon, Aixa
    Hoffman, Mark
    Black, Daniel
    Smith, Nicole
    Shamp, Wright
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [44] Visual performance and positional stability of a capsulorhexis-fixated extended depth-of-focus intraocular lens
    Darian-Smith, Erica
    Versace, Patrick
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (02): : 179 - 187
  • [45] Refractive Predictability of a Swept Source Optical Coherence Tomography Biometer in Long and Short Eyes Implanted with Extended Depth of Focus Intraocular Lenses
    Blehm, Clayton
    Hall, Brad
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 3525 - 3530
  • [46] Visual Outcomes and Patient Satisfaction for Trifocal, Extended Depth of Focus and Monofocal Intraocular Lenses
    Rodov, Luba
    Reitblat, Olga
    Levy, Adi
    Assia, Ehud, I
    Kleinmann, Guy
    JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (07) : 434 - +
  • [47] Comparative analysis of a presbyopia-correcting intraocular lens that combines extended depth-of-focus and bifocal profiles with a standard monofocal intraocular lens
    Shin, Da Eun
    Lee, Hun
    Koh, Kyungmin
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [48] Comparative analysis of a presbyopia-correcting intraocular lens that combines extended depth-of-focus and bifocal profiles with a standard monofocal intraocular lens
    Da Eun Shin
    Hun Lee
    Kyungmin Koh
    BMC Ophthalmology, 22
  • [49] Spherical aberration and depth of focus in eyes implanted with aspheric and spherical intraocular lenses -: A prospective randomized study
    Rocha, Karolinne Maia
    Soriano, Eduardo S.
    Chamon, Wallace
    Chalita, Maria Regina
    Nose, Walton
    OPHTHALMOLOGY, 2007, 114 (11) : 2050 - 2054
  • [50] Comment on: The Effect of a Spectral Filter on Visual Quality in Patients with an Extended-Depth-of-Focus Intraocular Lens
    Rosen, Robert
    Gounou, Franck
    Weeber, Henk
    Piers, Patricia
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 213 : 321 - 321