Effect of crystalline lens decentration and tilt on visual performance in eyes implanted with bifocal or extended depth of focus intraocular lenses

被引:0
|
作者
Zhang, Yu [1 ,2 ]
Zhang, Jiaqing [1 ]
Liang, Chen [1 ]
Xu, Yifan [1 ,2 ]
Wu, Jiaying [2 ]
Wu, Junming [2 ]
Zhang, Yifan [1 ,2 ]
Jin, Aixia [1 ,2 ]
Tan, Xuhua [1 ]
Luo, Lixia [1 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangdong Prov Key Lab Ophthalmol & Visual Sci, Guangzhou, Peoples R China
[2] Sun Yat Sen Univ Med Sci, Guangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Cataract; Intraocular lens; IOL; Presbyopia-correcting IOL; Decentration; Tilt; RETINAL IMAGE QUALITY; OPTICAL-QUALITY; CONTRAST SENSITIVITY; ABERRATION; PRECISION; VISION;
D O I
10.1186/s12886-025-03884-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo explore the potential of crystalline lens decentration and tilt as indicators for screening cataract patients for presbyopia-correcting intraocular lens (IOL) implantation. MethodsProspective observational study. Patients undergoing phacoemulsification with bifocal (Tecnis ZMB00) or extended depth-of-focus (EDOF) (Tecnis ZXR00) IOL implantation were consecutively enrolled. The decentration and tilt of the crystalline lens and the IOL were quantified through the utilization of swept-source optical coherence tomography (SS-OCT, Casia2). Postoperative visual acuity (VA), contrast sensitivity (CS), objective optical quality, and patient-reported outcomes were assessed at a 3-month follow-up. A LOWESS (LOcally WEighted Scatterplot Smoothing) curve was employed to analyze the changes in VA, CS, and objective optical quality relative to the decentration or tilt of crystalline lenses. A further comparison of visual outcomes was conducted based on the inflection points suggested by the curves. ResultsEighty-seven patients with ZMB00 IOL and 76 patients with ZXR00 IOL were included. Multiple 6-mm internal aberrations showed a nonlinear increase with greater crystalline lens decentration. The inflection points for the steep increase were observed to be 0.28 mm for the bifocal group and 0.35 mm for the EDOF group. Beyond these points, internal aberrations such as coma increased significantly (all P < 0.01). Patient satisfaction decreased (P < 0.01). Moreover, the bifocal group exhibited a decline in spectacle-independence from 98.67% to 83.33% (P = 0.049), along with a reduction in CS (P < 0.05). ConclusionsThe increased decentration of crystalline lenses compromises specific visual quality aspects in eyes implanted with ZMB00 and ZXR00 IOLs, with cut-off values of 0.28 mm and 0.35 mm, respectively.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Extended depth of focus intraocular lens: chromatic performance
    Millan, Maria S.
    Vega, Fidel
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (09): : 4294 - 4309
  • [22] Comparison of visual performance between extended depth of focus contact lens and single-vision contact lens in eyes with monofocal intraocular lens
    Takahiro Hiraoka
    Gaku Kiuchi
    Reia Hiraoka
    Junko Kotsuka
    Yumiko Kinoshita
    Tetsuro Oshika
    Japanese Journal of Ophthalmology, 2021, 65 : 803 - 809
  • [23] Comparison of visual performance between extended depth of focus contact lens and single-vision contact lens in eyes with monofocal intraocular lens
    Hiraoka, Takahiro
    Kiuchi, Gaku
    Hiraoka, Reia
    Kotsuka, Junko
    Kinoshita, Yumiko
    Oshika, Tetsuro
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2021, 65 (06) : 803 - 809
  • [24] Influence of extended depth of focus intraocular lenses on visual field sensitivity
    Takahashi, Makiko
    Yamashiro, Chiemi
    Yoshimoto, Takuya
    Kobayashi, Yuka
    Higashijima, Fumiaki
    Kobayashi, Masaaki
    Hatano, Makoto
    Ohta, Manami
    Nagai, Tomohiko
    Teranishi, Shinichiro
    Suzuki, Katsuyoshi
    Takabatake, Ryu
    Kimura, Kazuhiro
    PLOS ONE, 2020, 15 (09):
  • [25] Visual performance of a new Extended Depth of Focus (EDOF) intraocular lens: Preliminary results
    Moser Wurth, C. L.
    Lecumberri Lopez, M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2022, 45 (05): : 529 - 536
  • [26] Visual performance and patient preference with bilateral implantation of an extended depth of focus or combined implantation of an extended depth of focus/trifocal intraocular lens
    Moore, Jonathan
    Ostergaard, Jens
    Kretz, Florian
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [27] Visual Outcomes, Visual Quality and Patient Satisfaction: Comparing a Blended Bifocal Approach to Bilateral Extended Depth of Focus Intraocular Lens Implantation
    Hammond, Matthew D.
    Potvin, Richard
    CLINICAL OPHTHALMOLOGY, 2019, 13 : 2325 - 2332
  • [28] Visual simulation through different intraocular lenses using adaptive optics: Effect of tilt and decentration
    Madrid-Costa, David
    Ruiz-Alcocer, Javier
    Perez-Vives, Cari
    Ferrer-Blasco, Teresa
    Lopez-Gil, Norberto
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (06): : 947 - 958
  • [29] Influence of visual field on visual acuity and contrast sensitivity of glaucomatous eyes with monofocal and diffractive extended depth -of focus intraocular lenses
    Minami, Keiichiro
    Ota, Yuka
    Taira, Yoko
    Bissen-Miyajima, Hiroko
    Takemura, Ryo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [30] Comparative numerical analysis of astigmatism tolerance in bifocal, extended depth-of-focus, and trifocal intraocular lenses
    You, Jongin
    Jang, Mooseok
    BIOMEDICAL OPTICS EXPRESS, 2025, 16 (02): : 628 - 642