Research on Voltage Self-Calibration Sensing Technology Based on Measurement Circuit Topology Changes

被引:0
|
作者
Sun, Shangpeng [1 ]
Qiu, Zhenhui [2 ]
Song, Shijun [1 ]
He, Jianjian [3 ]
Ma, Feiyue [1 ]
Yang, Qing [2 ]
机构
[1] State Grid Ningxia Elect Power Co Ltd, Elect Power Sci Res Inst, Yinchuan 750002, Peoples R China
[2] Chongqing Univ, Natl Key Lab Power Transmiss & Transformat Equipme, Chongqing 400044, Peoples R China
[3] State Grid Ningxia Elect Power Co Ltd, Yinchuan 750001, Peoples R China
关键词
voltage and current sensing; circuit topology reconstruction; calibration accuracy analysis; signal monitoring; OVERHEAD TRANSMISSION-LINE;
D O I
10.3390/en17225672
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In capacitance-coupled voltage-sensing technology, the degree of coupling capacitance is affected by the sensing area, relative position deviation, and other factors, and thus the measurement coefficient is often difficult to determine accurately and presents greater implementation difficulties in actual deployment. This paper proposes a dynamic reconfiguration based on the measurement circuit topology of the voltage sensor adaptive calibration method in order to measure voltage sensor gain in the process of automatic measuring. Firstly, the basic principle of voltage measurement is introduced, and the self-calibration method is proposed, considering the influence of the sensing area and the relative position error on the change in the coupling capacitance. On this basis, the influence of calibration accuracy on sensor structure parameters is analyzed using network sensitivity analysis, and the parameter selection principle is given, according to which the selection criterion of parameter optimization is formulated to complete the sensor design. By analyzing the coupling effect of the three-phase measurement, the installation method of the sensing structure is proposed. An experimental platform is built to test the accuracy of the voltage measurement of the sensor under laboratory conditions. The experimental results show that the maximum relative error of the voltage measurement amplitude is 2.24%. In order to verify the feasibility of the sensor technology designed, the measurement models that integrate communication, acquisition, and processing are installed on both ends of the circuit breaker wire, and the voltage waveform generated during the circuit breaker closing process is recorded in real time. The experimental results show that the sensor technology can accurately record the voltage waveform of the signal to be measured, and the feasibility of its application in switchgear equipment signal measurement is preliminarily verified by the results.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Research on Self-calibration Algorithms Based on Optical Fiber Distributed Sensing Technology
    Liu, Yuan
    Li, Runchun
    Li, Haiming
    Sun, Yubao
    Du, Zhongping
    Jiang, Xinjun
    Liu, Tongyu
    SECOND SYMPOSIUM ON NOVEL TECHNOLOGY OF X-RAY IMAGING, 2019, 11068
  • [2] Self-Calibration Sensor for Contactless Voltage Measurement Based on Dynamic Capacitance
    Suo, Chunguang
    Huang, Rujin
    Zhou, Guoqiong
    Zhang, Wenbin
    Wang, Yanyun
    He, Mingxing
    SENSORS, 2023, 23 (08)
  • [3] Experimental Verification of Timing Measurement Circuit With Self-Calibration
    Chujo, Takeshi
    Hirabayashi, Daiki
    Li, Congbing
    Kobayashi, Yutaro
    Wang, Junshan
    Kobayashi, Haruo
    Katoh, Kentaroh
    Koshi, Sato
    2014 19TH INTERNATIONAL MIXED-SIGNALS, SENSORS AND SYSTEMS TEST WORKSHOP (IMS3TW), 2014,
  • [4] Self-Calibration Method of Noncontact AC Voltage Measurement
    Zhang, Wenbin
    Wei, Ran
    Jiu, Aerduoni
    Cheng, Kang
    Yang, Yonglong
    Suo, Chunguang
    ELECTRONICS, 2023, 12 (02)
  • [5] Research on orbit sequential recursive self-calibration technology
    Yang Ping
    Liu Lisheng
    Yang Zewang
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 4763 - 4766
  • [6] A self-calibration method of non-contact voltage measurement based on impedance transformation
    Huang R.
    Suo C.
    Zhang W.
    Zhu J.
    Zou X.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2023, 44 (03): : 137 - 145
  • [7] Self-calibration and biconvex compressive sensing
    Ling, Shuyang
    Strohmer, Thomas
    INVERSE PROBLEMS, 2015, 31 (11)
  • [8] Research on self-calibration biaxial autocollimator based on ZYNQ
    Guo, Pan
    Liu, Bingguo
    Liu, Guodong
    Zhong, Yao
    Lu, Binghui
    2017 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTICAL SYSTEMS AND MODERN OPTOELECTRONIC INSTRUMENTS, 2017, 10616
  • [9] A New Resistive Voltage Divider with Self-Calibration
    Zhao, Wenpeng
    Shi, Yang
    Qian, Lushuai
    Zhang, Dandan
    Zhao, Jianting
    2024 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS, CPEM 2024, 2024,
  • [10] A LEARNING ALGORITHM FOR SELF-CALIBRATION OF A VOLTAGE CALIBRATOR
    DRNOVSEK, J
    FEFER, D
    JEGLIC, A
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1992, 41 (06) : 991 - 996