关键词
voltage and current sensing; circuit topology reconstruction; calibration accuracy analysis; signal monitoring; OVERHEAD TRANSMISSION-LINE;
D O I
10.3390/en17225672
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In capacitance-coupled voltage-sensing technology, the degree of coupling capacitance is affected by the sensing area, relative position deviation, and other factors, and thus the measurement coefficient is often difficult to determine accurately and presents greater implementation difficulties in actual deployment. This paper proposes a dynamic reconfiguration based on the measurement circuit topology of the voltage sensor adaptive calibration method in order to measure voltage sensor gain in the process of automatic measuring. Firstly, the basic principle of voltage measurement is introduced, and the self-calibration method is proposed, considering the influence of the sensing area and the relative position error on the change in the coupling capacitance. On this basis, the influence of calibration accuracy on sensor structure parameters is analyzed using network sensitivity analysis, and the parameter selection principle is given, according to which the selection criterion of parameter optimization is formulated to complete the sensor design. By analyzing the coupling effect of the three-phase measurement, the installation method of the sensing structure is proposed. An experimental platform is built to test the accuracy of the voltage measurement of the sensor under laboratory conditions. The experimental results show that the maximum relative error of the voltage measurement amplitude is 2.24%. In order to verify the feasibility of the sensor technology designed, the measurement models that integrate communication, acquisition, and processing are installed on both ends of the circuit breaker wire, and the voltage waveform generated during the circuit breaker closing process is recorded in real time. The experimental results show that the sensor technology can accurately record the voltage waveform of the signal to be measured, and the feasibility of its application in switchgear equipment signal measurement is preliminarily verified by the results.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] A digital self-calibration circuit for optical rotary encoder microsystems
    Cherchi, F
    Disingrini, L
    Gregori, S
    Torelli, G
    Liberali, V
    Gottardi, M
    IMTC/2001: PROCEEDINGS OF THE 18TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3: REDISCOVERING MEASUREMENT IN THE AGE OF INFORMATICS, 2001, : 1619 - 1624
  • [32] Measurement and correction of lateral distortion in a Fizeau interferometer based on the self-calibration technique
    Qiao, Xiaoyue
    Bai, Yunbo
    Ding, Guoqing
    Wang, Weiwei
    Liu, Shijie
    Cai, Ping
    Chen, Xin
    Su, Rong
    OPTICS EXPRESS, 2022, 30 (20) : 36134 - 36143
  • [33] Ultrasonic thickness measurement technique with self-calibration function
    Gan, Fangji
    Min, Lin
    Tao, Xu
    Liao, Junbi
    INSIGHT, 2018, 60 (11) : 619 - +
  • [34] Improved algorithm of self-calibration technology by the ground-based microwave radiometer
    Li, Jiangman
    Guo, Lixin
    Lin, Leke
    Zhao, Zhenwei
    Shu, Tingting
    Chen, Houcai
    Xi'an Dianzi Keji Daxue Xuebao/Journal of Xidian University, 2014, 41 (04): : 77 - 81
  • [35] Real time self-calibration of digital measurement system
    Xi, YB
    Gu, TX
    2005 INTERNATIONAL CONFERENCE ON COMMUNICATIONS, CIRCUITS AND SYSTEMS, VOLS 1 AND 2, PROCEEDINGS: VOL 1: COMMUNICATION THEORY AND SYSTEMS, 2005, : 1362 - 1365
  • [36] 3D Measurement Based on Phase-shift and Self-calibration
    Chen Liangzhou
    Xu Yongjie
    Xiao Dan
    EIGHTH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2013, 8759
  • [37] Self-Calibration for MEMS With Comb Drives: Measurement of Gap
    Li, Fengyuan
    Clark, Jason Vaughn
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2012, 21 (05) : 1019 - 1021
  • [38] AIRCRAFT MEASUREMENT OF ELECTRIC-FIELD - SELF-CALIBRATION
    WINN, WP
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1993, 98 (D4) : 7351 - 7365
  • [39] Self-calibration and data fusion for humidity measurement system
    Huang Xiao-yin
    Zhou Ping
    Zhang Yue
    PROCEEDINGS OF 2005 CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1 AND 2, 2005, : 1265 - 1268
  • [40] Research on Self Calibration Technology for Precision Workpiece Measurement Based on Laser Doppler Vibrometer
    Ma, Xie
    Li, Ming
    Ye, Lingjian
    Ma, Xiushui
    Yu, Kaidong
    Zhu, Leilei
    Song, Yunfeng
    INTEGRATED FERROELECTRICS, 2019, 199 (01) : 160 - 171