摘要
In capacitance-coupled voltage-sensing technology, the degree of coupling capacitance is affected by the sensing area, relative position deviation, and other factors, and thus the measurement coefficient is often difficult to determine accurately and presents greater implementation difficulties in actual deployment. This paper proposes a dynamic reconfiguration based on the measurement circuit topology of the voltage sensor adaptive calibration method in order to measure voltage sensor gain in the process of automatic measuring. Firstly, the basic principle of voltage measurement is introduced, and the self-calibration method is proposed, considering the influence of the sensing area and the relative position error on the change in the coupling capacitance. On this basis, the influence of calibration accuracy on sensor structure parameters is analyzed using network sensitivity analysis, and the parameter selection principle is given, according to which the selection criterion of parameter optimization is formulated to complete the sensor design. By analyzing the coupling effect of the three-phase measurement, the installation method of the sensing structure is proposed. An experimental platform is built to test the accuracy of the voltage measurement of the sensor under laboratory conditions. The experimental results show that the maximum relative error of the voltage measurement amplitude is 2.24%. In order to verify the feasibility of the sensor technology designed, the measurement models that integrate communication, acquisition, and processing are installed on both ends of the circuit breaker wire, and the voltage waveform generated during the circuit breaker closing process is recorded in real time. The experimental results show that the sensor technology can accurately record the voltage waveform of the signal to be measured, and the feasibility of its application in switchgear equipment signal measurement is preliminarily verified by the results.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Efficient camera self-calibration method for remote sensing photogrammetry
    Li, Jin
    Liu, Zilong
    OPTICS EXPRESS, 2018, 26 (11): : 14213 - 14231
  • [42] Displacement sensing HeNe laser with λ/8 accuracy and self-calibration
    Li, Y
    Zhang, SL
    Han, YM
    Fu, J
    Guo, N
    Ou, JM
    OPTICAL ENGINEERING, 2000, 39 (11) : 3039 - 3043
  • [43] Temperature Self-Calibration of Always-On, Field-Deployed Ion- Selective Electrodes Based on Differential Voltage Measurement
    Saha, Ajanta
    Yermembetova, Aiganym
    Mi, Ye
    Gopalakrishnan, Sarath
    Sedaghat, Sotoudeh
    Waimin, Jose
    Wang, Pengcheng
    Glassmaker, Nicholas
    Mousoulis, Charilaos
    Raghunathan, Nithin
    Bagchi, Saurabh
    Rahimi, Rahim
    Shakouri, Ali
    Wei, Alexander
    Alam, Muhammad A.
    ACS SENSORS, 2022, 7 (09) : 2661 - 2670
  • [44] Research on method of sensor self-calibration based on the characteristic of rectangular vanishing point
    Zeng Zhao-yang
    Cheng Xiang-zheng
    Chen Hang
    Huang Chao
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2013: IMAGING SENSORS AND APPLICATIONS, 2013, 8908
  • [45] Research on rapid self-calibration method for inertial platform
    Cao Y.
    Zhang S.-F.
    Yang H.-B.
    Cai H.
    Yuhang Xuebao/Journal of Astronautics, 2011, 32 (06): : 1281 - 1287
  • [46] Camera Self-calibration Based on the Vanishing Points
    Chang, Dongsheng
    Wang, Kuanquan
    Wang, Lianqing
    ARTIFICIAL INTELLIGENCE AND COMPUTATIONAL INTELLIGENCE, PT III, 2011, 7004 : 47 - +
  • [47] Purity-based self-calibration in ptychography
    Liu, Chang
    Eschen, Wilhelm
    Molina, Daniel s. penagos
    Licht, Leona
    Abdelaal, Mahmoud
    Rothhardt, Jan
    OPTICS LETTERS, 2025, 50 (05) : 1581 - 1584
  • [48] Self-calibration scheme of RIMU based on AEKF
    Cheng, Jianhua
    Liu, Ping
    Wei, Zhenyu
    Dong, Ping
    GLOBAL OCEANS 2020: SINGAPORE - U.S. GULF COAST, 2020,
  • [49] Circle-based self-calibration of camera
    Zhang, B.W.
    Wu, F.C.
    Moshi Shibie yu Rengong Zhineng/Pattern Recognition and Artificial Intelligence, 2001, 14 (02):
  • [50] An Improved Rotation-based Self-calibration
    Li, Canlin
    Lu, Jiajie
    Ma, Lizhuang
    2009 11TH IEEE INTERNATIONAL CONFERENCE ON COMPUTER-AIDED DESIGN AND COMPUTER GRAPHICS, PROCEEDINGS, 2009, : 623 - 626