A numerical study on cooling performance of different type earth-air heat exchangers

被引:1
|
作者
Tasdelen, Fatih [1 ]
Dagtekin, Ihsan [2 ]
机构
[1] Bitlis Eren Univ, Vocat Sch Tech Sci, TR-13000 Bitlis, Turkiye
[2] Firat Univ, Dept Mech Engn, TR-23119 Elazig, Turkiye
关键词
Earth-air heat exchanger; Temperature; Cooling performance; Soil; CFD; Re number; FLOW CHARACTERISTICS; THERMAL PERFORMANCE; SYSTEM; SOIL; SIMULATION; EAHE; VENTILATION; HOT; VALIDATION; BUILDINGS;
D O I
10.1016/j.renene.2024.122325
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Greenhouse gases released into the atmosphere are among the most important causes of climate change which affects the whole world today. The use of renewable energy sources should be encouraged in order to minimize greenhouse gas emissions increasing with the consumption of fossil energy sources. Energy consumption and greenhouse gas emission values of Earth-Air Heat Exchangers (EAHEs), which are systems based on renewable energy are quite low. In this study, analyses regarding the cooling performance of 3D-modeled different type (4 horizontal and 4 vertical) EAHEs with equal pipe lengths have been carried out in ANSYS FLUENT 19.2 software based on Computational Fluid Dynamics (CFD). The cooling performances of EAHEs have been examined within the Reynolds numbers range of (5x103 < Re < 105). Rises in the Reynolds number significantly influence the cooling efficacy of the EAHEs, whereas the soil thermal conductivity has less impact on their cooling efficiency. Mean air temperature reductions of 14.90 K and 18.44 K have been recorded for the Re = 5x103 value, while reductions of 8.12 K and 8.07 K have been seen for the Re = 105 value of the horizontal and vertical EAHEs, respectively. The energy savings for the EAHEs demonstrating better cooling performance over the summer season have been examined. The optimal energy saving for these EAHEs has been attained at the Reynolds number of 6x104. At the Reynolds number of 6x104, 378.048 kWh and 397.275 kWh of energy savings have been obtained for horizontal and vertical EAHEs, respectively. The maximum financial savings for H-model III and Vmodel IV EAHE over the summer season were 32.285 euros and 33.927 euros, respectively, at the Reynolds number of 6x104.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Research on cooling performance of phase change material-filled earth-air heat exchanger
    Zhou, Tiecheng
    Xiao, Yimin
    Liu, Yanan
    Lin, Jianquan
    Huang, Haotian
    ENERGY CONVERSION AND MANAGEMENT, 2018, 177 : 210 - 223
  • [42] Influence of daily temperature behavior on earth-air heat exchangers: A case study from Aichi, Japan
    Zajch, Andrew
    Gough, William A.
    Yoon, Gyuyoung
    CITY AND ENVIRONMENT INTERACTIONS, 2020, 8
  • [43] Study of the energy performance of an earth-Air heat exchanger for refreshing buildings in Algeria
    Menhoudj, Sayeh
    Mokhtari, Abderrahmane-Mejedoub
    Benzaama, Mohamed-Hichem
    Maalouf, Chadi
    Lachi, Mohamed
    Makhlouf, Mohammed
    ENERGY AND BUILDINGS, 2018, 158 : 1602 - 1612
  • [44] PERFORMANCE OF EARTH-AIR TUNNEL SYSTEM FOR DIFFERENT EARTH SURFACE TREATMENTS
    SODHA, MS
    SAWHNEY, RL
    SHARMA, AK
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1989, 13 (04) : 477 - 490
  • [45] Experimental study on the characteristics of radiation floor cooling system based on an earth-air heat exchanger
    Yang, Jiaming
    Song, Wei
    Zhang, Houan
    Wang, Jing
    Dong, Jiankai
    ENERGY AND BUILDINGS, 2023, 296
  • [46] Evaluation of Earth-air Heat Exchanger for Cooling and Heating a Poultry House: Case Study in Morocco
    Laknizi, Azzeddine
    ElMaakoul, Anas
    Ben Abdellah, Abdellatif
    Bouya, Mouhsine
    Dhimdi, Said
    Said, Saadeddine
    PROCEEDINGS OF 2015 3RD IEEE INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC'15), 2015, : 435 - 439
  • [47] PERFORMANCE EVALUATION OF BUILDINGS ASSOCIATED WITH EARTH TO AIR HEAT-EXCHANGERS - THE COOLING POTENTIAL
    SANTAMOURIS, M
    AGAS, G
    MATSAGOS, T
    ARGYRIOU, T
    THEOFILAKTOS, K
    ARCHITECTURE AND URBAN SPACE, 1991, : 637 - 642
  • [48] CLOSED GREENHOUSE HEATING IN AN ARID EGYPTIAN WINTER USING EARTH-AIR HEAT EXCHANGERS
    Hegazy, Anwar
    Subiantoro, Alison
    Norris, Stuart
    PROCEEDINGS OF ASME 2021 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION (IMECE2021), VOL 11, 2021,
  • [49] Performance of earth-air heat exchanger in cooling, heating, and reducing carbon emissions of an industrial poultry farm: A case study
    Boutera, Yousra
    Boultif, Nora
    Rouag, Amar
    Beldjani, Charafeddine
    Moummi, Noureddine
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2022, 44 (04) : 9564 - 9583
  • [50] Experimental investigation on the performance of earth-air pipe heat exchanger for different soil compaction levels
    Elminshawy, Nabil A. S.
    Siddiqui, Farooq R.
    Farooq, Qazi U.
    Addas, Mohammad F.
    APPLIED THERMAL ENGINEERING, 2017, 124 : 1319 - 1327