A numerical study on cooling performance of different type earth-air heat exchangers

被引:1
|
作者
Tasdelen, Fatih [1 ]
Dagtekin, Ihsan [2 ]
机构
[1] Bitlis Eren Univ, Vocat Sch Tech Sci, TR-13000 Bitlis, Turkiye
[2] Firat Univ, Dept Mech Engn, TR-23119 Elazig, Turkiye
关键词
Earth-air heat exchanger; Temperature; Cooling performance; Soil; CFD; Re number; FLOW CHARACTERISTICS; THERMAL PERFORMANCE; SYSTEM; SOIL; SIMULATION; EAHE; VENTILATION; HOT; VALIDATION; BUILDINGS;
D O I
10.1016/j.renene.2024.122325
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Greenhouse gases released into the atmosphere are among the most important causes of climate change which affects the whole world today. The use of renewable energy sources should be encouraged in order to minimize greenhouse gas emissions increasing with the consumption of fossil energy sources. Energy consumption and greenhouse gas emission values of Earth-Air Heat Exchangers (EAHEs), which are systems based on renewable energy are quite low. In this study, analyses regarding the cooling performance of 3D-modeled different type (4 horizontal and 4 vertical) EAHEs with equal pipe lengths have been carried out in ANSYS FLUENT 19.2 software based on Computational Fluid Dynamics (CFD). The cooling performances of EAHEs have been examined within the Reynolds numbers range of (5x103 < Re < 105). Rises in the Reynolds number significantly influence the cooling efficacy of the EAHEs, whereas the soil thermal conductivity has less impact on their cooling efficiency. Mean air temperature reductions of 14.90 K and 18.44 K have been recorded for the Re = 5x103 value, while reductions of 8.12 K and 8.07 K have been seen for the Re = 105 value of the horizontal and vertical EAHEs, respectively. The energy savings for the EAHEs demonstrating better cooling performance over the summer season have been examined. The optimal energy saving for these EAHEs has been attained at the Reynolds number of 6x104. At the Reynolds number of 6x104, 378.048 kWh and 397.275 kWh of energy savings have been obtained for horizontal and vertical EAHEs, respectively. The maximum financial savings for H-model III and Vmodel IV EAHE over the summer season were 32.285 euros and 33.927 euros, respectively, at the Reynolds number of 6x104.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Transient Models to Analyze the Influence of the Air Velocity and Ducts Diameter on the Performance of Earth-Air Heat Exchangers
    Brum, R. S.
    Ramalho, J. V. A.
    Rocha, L. A. O.
    Isoldi, L. A.
    dos Santos, E. D.
    INTERNATIONAL JOURNAL OF FLUID MECHANICS RESEARCH, 2016, 43 (5-6) : 503 - 520
  • [22] Thermal performance simulations of Earth-Air Heat Exchangers for different soils of a coastal city using in-situ data
    Rodrigues, M. K.
    Coswig, F. S.
    Camargo, K. R.
    Isoldi, L. A.
    Brum, R. S.
    Ramalho, J. V. A.
    Vaz, J.
    Rocha, L. A. O.
    dos Santos, E. D.
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2018, 30 : 224 - 229
  • [23] Experimental and numerical analysis of an earth-air heat exchanger
    Vaz, Joaquim
    Sattler, Miguel A.
    dos Santos, Elizaldo D.
    Isoldi, Liercio A.
    ENERGY AND BUILDINGS, 2011, 43 (09) : 2476 - 2482
  • [24] Influence of different types of pipes on the heat exchange performance of an earth-air heat exchanger
    Xiao, Jinxin
    Li, Jianming
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 55
  • [25] Performance Analysis of PCM Ceiling Coupling with Earth-Air Heat Exchanger for Building Cooling
    Lu, Shilei
    Liang, Bin
    Li, Xinhua
    Kong, Xiangfei
    Jia, Wei
    Wang, Lu
    MATERIALS, 2020, 13 (13) : 1 - 17
  • [26] Numerical study on the cooling performance of a novel passive system: Cylindrical phase change material-assisted earth-air heat exchanger
    Zhou, Tiecheng
    Xiao, Yimin
    Huang, Haotian
    Lin, Jianquan
    JOURNAL OF CLEANER PRODUCTION, 2020, 245
  • [27] A parametric analysis of the cooling performance of vertical earth-air heat exchanger in a subtropical climate
    Ahmed, S. F.
    Khan, M. M. K.
    Amanullah, M. T. O.
    Rasul, M. G.
    Hassan, N. M. S.
    RENEWABLE ENERGY, 2021, 172 : 350 - 367
  • [28] A new computational modeling to predict the behavior of Earth-Air Heat Exchangers
    Brum, Ruth da Silva
    Vaz, Joaquim
    Oliveira Rocha, Luiz Alberto
    dos Santos, Elizaldo Domingues
    Isoldi, Liercio Andre
    ENERGY AND BUILDINGS, 2013, 64 : 395 - 402
  • [29] THERMAL PERFORMANCE OF EARTH-AIR HEAT EXCHANGER SYSTEMS FOR COOLING APPLICATIONS IN RESIDENTIAL BUILDINGS
    Ghaith, Fadi A.
    Razzaq, Habib Ur
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2018, VOL 6A, 2019,
  • [30] Numerical and Experimental Analysis of an Earth-Air Heat Exchanger
    Diedrich, Carlos Henrique
    dos Santos, Gerson Henrique
    Carraro, Gustavo Chaves
    Dimbarre, Victor Vaurek
    Alves, Thiago Antonini
    ATMOSPHERE, 2023, 14 (07)