A numerical study on cooling performance of different type earth-air heat exchangers

被引:1
|
作者
Tasdelen, Fatih [1 ]
Dagtekin, Ihsan [2 ]
机构
[1] Bitlis Eren Univ, Vocat Sch Tech Sci, TR-13000 Bitlis, Turkiye
[2] Firat Univ, Dept Mech Engn, TR-23119 Elazig, Turkiye
关键词
Earth-air heat exchanger; Temperature; Cooling performance; Soil; CFD; Re number; FLOW CHARACTERISTICS; THERMAL PERFORMANCE; SYSTEM; SOIL; SIMULATION; EAHE; VENTILATION; HOT; VALIDATION; BUILDINGS;
D O I
10.1016/j.renene.2024.122325
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Greenhouse gases released into the atmosphere are among the most important causes of climate change which affects the whole world today. The use of renewable energy sources should be encouraged in order to minimize greenhouse gas emissions increasing with the consumption of fossil energy sources. Energy consumption and greenhouse gas emission values of Earth-Air Heat Exchangers (EAHEs), which are systems based on renewable energy are quite low. In this study, analyses regarding the cooling performance of 3D-modeled different type (4 horizontal and 4 vertical) EAHEs with equal pipe lengths have been carried out in ANSYS FLUENT 19.2 software based on Computational Fluid Dynamics (CFD). The cooling performances of EAHEs have been examined within the Reynolds numbers range of (5x103 < Re < 105). Rises in the Reynolds number significantly influence the cooling efficacy of the EAHEs, whereas the soil thermal conductivity has less impact on their cooling efficiency. Mean air temperature reductions of 14.90 K and 18.44 K have been recorded for the Re = 5x103 value, while reductions of 8.12 K and 8.07 K have been seen for the Re = 105 value of the horizontal and vertical EAHEs, respectively. The energy savings for the EAHEs demonstrating better cooling performance over the summer season have been examined. The optimal energy saving for these EAHEs has been attained at the Reynolds number of 6x104. At the Reynolds number of 6x104, 378.048 kWh and 397.275 kWh of energy savings have been obtained for horizontal and vertical EAHEs, respectively. The maximum financial savings for H-model III and Vmodel IV EAHE over the summer season were 32.285 euros and 33.927 euros, respectively, at the Reynolds number of 6x104.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Parametric and experimental study on thermal performance of an earth-air heat exchanger
    Shukla, Ashish
    Tiwari, G. N.
    Sodha, M. S.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2006, 30 (06) : 365 - 379
  • [32] Earth-to-air heat exchangers cooling evaluation for different climates of Iran
    Shojaee, Seyed Mohammad Nima
    Malek, Kaveh
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2017, 23 : 111 - 120
  • [33] Numerical simulation of the heat transfer in an earth-air heat exchange system
    Wu, Hui-Jun
    Zhu, Dong-Sheng
    Sun, Jia-Long
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2004, 32 (11): : 24 - 27
  • [34] Effect of geo-climatic conditions and pipe material on heating performance of earth-air heat exchangers
    Lekhal, Mohammed Cherif
    Benzaama, Mohammed-Hichem
    Kindinis, Andrea
    Mokhtari, Abderahmane-Mejedoub
    Belarbi, Rafik
    RENEWABLE ENERGY, 2021, 163 : 22 - 40
  • [35] Thermal resistance capacity model for transient simulation of Earth-Air Heat Exchangers
    Minaei, Asgar
    Talee, Zahra
    Safikhani, Hamed
    Ghaebi, Hadi
    RENEWABLE ENERGY, 2021, 167 : 558 - 567
  • [36] ON THE COOLING POTENTIAL OF EARTH TO AIR HEAT-EXCHANGERS
    MIHALAKAKOU, G
    SANTAMOURIS, M
    ASIMAKOPOULOS, D
    ENERGY CONVERSION AND MANAGEMENT, 1994, 35 (05) : 395 - 402
  • [37] Fitting new constructal models for the thermal potential of earth-air heat exchangers
    de Alencar Ramalho, Jairo Valoes
    Brum, Ruth da Silva
    Oliveira Rocha, Luiz Alberto
    Isoldi, Liercio Andre
    dos Santos, Elizaldo Domingues
    Sulzbacher, Mariane
    ACTA SCIENTIARUM-TECHNOLOGY, 2018, 40
  • [38] Design-oriented modelling on cooling performance of the earth-air heat exchanger for livestock housing
    Wang, Xiaoshuai
    Bjerg, Bjarne Schmidt
    Zhang, Guoqiang
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2018, 152 : 51 - 58
  • [39] An evaluation for spiral coil type earth-air heat exchanger at different climate conditions
    Jamshidi, Naghmeh
    Sadafi, Nasibeh
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2020, 42 (24) : 3045 - 3062
  • [40] ENHANCING THE PERFORMANCE OF THE BUILDING'S VAPOR COMPRESSION AIR COOLING SYSTEM USING EARTH-AIR HEAT EXCHANGER
    Ghaith, Fadi A.
    Alsouda, Fadi J.
    PROCEEDINGS OF THE ASME 11TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2017, 2017,