Radio interference characteristics of UHVAC test lines and prediction for long lines

被引:0
|
作者
He, Wangling [1 ,2 ]
Wan, Baoquan [2 ]
Liu, Zhenhuan [2 ]
Pei, Chunming [2 ]
He, Junjia [1 ]
Zhang, Jin [2 ]
机构
[1] School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan,430074, China
[2] China Electric Power Research Institute, Wuhan,430074, China
来源
关键词
Electric corona - Elastic waves - Electric impedance measurement - Functions - Testing - Modal analysis;
D O I
10.13336/j.1003-6520.hve.2014.12.041
中图分类号
学科分类号
摘要
In order to accurately evaluate the radio interference (RI) level generated by ultra-high voltage alternating current (UHV AC) power lines, we theoretically analyzed multi-conductor test line using the modal analysis method. The RI field strength distribution characteristics under test lines were deduced when the line terminals were connected to three different typical impedance networks, respectively. Then we measured the standing wave when both line ends were opened. Moreover, on the basis of the test line arrangement in UHV AC Test Base in Wuhan and the RI characteristics of short test lines, we obtained the excitation function value using the mathematical inversion from the measured RI at 0.5 MHz under the condition of heavy rain. Then we applied the excitation function value to predict and analyze the RI distributions of Jindongnan-Nanyang-Jingmen 1000 kV transmission lines, and compared the results with measured data. The results show that the excitation value of 8×LGJ-500/35 line with applied voltage of 1050 kV is 39.3 dB, and when the measurement point is less than 60 meters far from the center phase of bundle conductors, the difference between the predicted excitation function values and the measured RI values is less than 2 dB. This proves the feasibility of using the mathematical inversion to calculate excitation function values for short test lines. ©, 2014, Science Press. All right reserved.
引用
收藏
页码:3953 / 3960
相关论文
共 50 条
  • [41] CORONA AND RADIO INTERFERENCE PERFORMANCE OF THE NELSON RIVER HVDC TRANSMISSION LINES.
    Morris, R.M.
    Morse, A.R.
    Griffin, J.P.
    Norris-Elye, O.C.
    Thio, C.V.
    Goodman, J.S.
    1979,
  • [42] CORONA AND RADIO INTERFERENCE PERFORMANCE OF THE NELSON RIVER HVDC TRANSMISSION-LINES
    MORRIS, RM
    MORSE, AR
    GRIFFIN, JP
    NORRISELYE, OC
    THIO, CV
    GOODMAN, JS
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (06): : 1924 - 1936
  • [43] Limits and design control of radio interference for 1000 kV AC transmission lines
    Wu, Xiong
    Li, Ni
    Zhang, Guang-Zhou
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (08): : 1791 - 1795
  • [44] Statistic analysis of long-term measured data of radio interference on UHV AC demonstration project transmission lines
    Zhang, Yemao
    Zhang, Jiangong
    Wu, Xiong
    Li, Ni
    Xie, Huichun
    Liu, Xingfa
    Gaodianya Jishu/High Voltage Engineering, 2015, 41 (11): : 3708 - 3714
  • [46] Calculation of the probability characteristics of power line hazardous interference with telecommunications lines
    Habibulina, G.I.
    Telecommunications and Radio Engineering (English translation of Elektrosvyaz and Radiotekhnika), 1988, 43 (04): : 10 - 13
  • [47] Establishment and transcriptomic characteristics of radio-resistant meningioma cell lines
    Yu, Jinxiu
    Ren, Leihao
    Wu, Tianqi
    Hua, Lingyang
    Wang, Daijun
    Wang, Yang
    Xie, Qing
    Deng, Jiaojiao
    Gong, Ye
    JOURNAL OF NEURO-ONCOLOGY, 2025, : 105 - 119
  • [48] SPECTRAL LINES IN RADIO ASTRONOMY
    BARRETT, AH
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1958, 46 (01): : 250 - 259
  • [49] Radio Recombination Lines of Hydrogen
    Peach, G.
    JOURNAL OF ASTROPHYSICS AND ASTRONOMY, 2015, 36 (04) : 555 - 563
  • [50] Cosmological radio recombination lines
    Eroshenko, Yu N.
    PHYSICS-USPEKHI, 2019, 62 (01) : 108 - 109