Radio interference characteristics of UHVAC test lines and prediction for long lines

被引:0
|
作者
He, Wangling [1 ,2 ]
Wan, Baoquan [2 ]
Liu, Zhenhuan [2 ]
Pei, Chunming [2 ]
He, Junjia [1 ]
Zhang, Jin [2 ]
机构
[1] School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan,430074, China
[2] China Electric Power Research Institute, Wuhan,430074, China
来源
关键词
Electric corona - Elastic waves - Electric impedance measurement - Functions - Testing - Modal analysis;
D O I
10.13336/j.1003-6520.hve.2014.12.041
中图分类号
学科分类号
摘要
In order to accurately evaluate the radio interference (RI) level generated by ultra-high voltage alternating current (UHV AC) power lines, we theoretically analyzed multi-conductor test line using the modal analysis method. The RI field strength distribution characteristics under test lines were deduced when the line terminals were connected to three different typical impedance networks, respectively. Then we measured the standing wave when both line ends were opened. Moreover, on the basis of the test line arrangement in UHV AC Test Base in Wuhan and the RI characteristics of short test lines, we obtained the excitation function value using the mathematical inversion from the measured RI at 0.5 MHz under the condition of heavy rain. Then we applied the excitation function value to predict and analyze the RI distributions of Jindongnan-Nanyang-Jingmen 1000 kV transmission lines, and compared the results with measured data. The results show that the excitation value of 8×LGJ-500/35 line with applied voltage of 1050 kV is 39.3 dB, and when the measurement point is less than 60 meters far from the center phase of bundle conductors, the difference between the predicted excitation function values and the measured RI values is less than 2 dB. This proves the feasibility of using the mathematical inversion to calculate excitation function values for short test lines. ©, 2014, Science Press. All right reserved.
引用
收藏
页码:3953 / 3960
相关论文
共 50 条
  • [31] INTERFERENCE COMPTON LINES
    LYUBIMOV, AG
    KRISTALLOGRAFIYA, 1993, 38 (03): : 195 - 196
  • [32] Safe Distance for Inspection of 1 000 kV UHVAC Lines with Helicopter
    Shen Jian1
    Electricity, 2012, 23 (01) : 21 - 25
  • [33] Lightning shielding failure analysis of UHVAC transmission lines with an improved EGM
    Yuan, Haiyan
    Fu, Zhengcal
    Wei, Bengang
    Du, Yaping
    HKIE Transactions Hong Kong Institution of Engineers, 2009, 16 (03): : 42 - 47
  • [34] Radio interference from EHV transmission lines and norms requirements to radio interference levels of insulator strings and line fittings
    Krylov, SV
    Timashova, LV
    ELECTROMAGNETIC COMPATIBILITY 1996 - THIRTEENTH INTERNATIONAL WROCLAW SYMPOSIUM, 1996, : 272 - 275
  • [35] Radio recombination lines
    Konovalenko, AA
    Stepkini, SV
    RADIO ASTRONOMY FROM KARL JANSKY TO MICROJANSKY, 2005, 15 : 271 - 295
  • [36] RADIO RECOMBINATION LINES
    BROWN, RL
    LOCKMAN, FJ
    KNAPP, GR
    ANNUAL REVIEW OF ASTRONOMY AND ASTROPHYSICS, 1978, 16 : 445 - 485
  • [37] Characteristics of Multi-Mode Interference Couplers by the Method of Lines
    Syahriar, Ary
    Adam, Helmi
    Djamal, Jusman Syafii
    Lubis, H. Ahmad
    Saleh, Randy Rahmat
    ADVANCED SCIENCE LETTERS, 2017, 23 (04) : 3700 - 3703
  • [38] Study on Reradiation Interference Characteristics of Steel Towers in Transmission Lines
    Huang, Li
    Tang, Bo
    Liu, Xingfa
    Liu, Jianben
    INFORMATION, 2022, 13 (11)
  • [39] ANALYSIS OF RADIO INTERFERENCE FROM SHORT MULTI-CONDUCTOR LINES .2. ANALYTICAL AND TEST-RESULTS
    DALLAIRE, RD
    MARUVADA, PS
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (04): : 2109 - 2119
  • [40] 'SHORT LINES AND LONG LINES OF POETRY'
    NWANKWO, C
    OKIKE-AN AFRICAN JOURNAL OF NEW WRITING, 1981, (18): : 73 - 73