Radio interference characteristics of UHVAC test lines and prediction for long lines

被引:0
|
作者
He, Wangling [1 ,2 ]
Wan, Baoquan [2 ]
Liu, Zhenhuan [2 ]
Pei, Chunming [2 ]
He, Junjia [1 ]
Zhang, Jin [2 ]
机构
[1] School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan,430074, China
[2] China Electric Power Research Institute, Wuhan,430074, China
来源
关键词
Electric corona - Elastic waves - Electric impedance measurement - Functions - Testing - Modal analysis;
D O I
10.13336/j.1003-6520.hve.2014.12.041
中图分类号
学科分类号
摘要
In order to accurately evaluate the radio interference (RI) level generated by ultra-high voltage alternating current (UHV AC) power lines, we theoretically analyzed multi-conductor test line using the modal analysis method. The RI field strength distribution characteristics under test lines were deduced when the line terminals were connected to three different typical impedance networks, respectively. Then we measured the standing wave when both line ends were opened. Moreover, on the basis of the test line arrangement in UHV AC Test Base in Wuhan and the RI characteristics of short test lines, we obtained the excitation function value using the mathematical inversion from the measured RI at 0.5 MHz under the condition of heavy rain. Then we applied the excitation function value to predict and analyze the RI distributions of Jindongnan-Nanyang-Jingmen 1000 kV transmission lines, and compared the results with measured data. The results show that the excitation value of 8×LGJ-500/35 line with applied voltage of 1050 kV is 39.3 dB, and when the measurement point is less than 60 meters far from the center phase of bundle conductors, the difference between the predicted excitation function values and the measured RI values is less than 2 dB. This proves the feasibility of using the mathematical inversion to calculate excitation function values for short test lines. ©, 2014, Science Press. All right reserved.
引用
收藏
页码:3953 / 3960
相关论文
共 50 条
  • [21] MODEL FOR RADIO INTERFERENCE PRODUCED BY CORONA PULSES ON AC LINES
    GILCHRIST, JH
    THOMAS, JB
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1975, 122 (11): : 1260 - 1264
  • [22] ANALYSIS OF RADIO INTERFERENCE FROM SHORT MULTICONDUCTOR LINES - 2. ANALYTICAL AND TEST RESULTS.
    Dallaire, R.Daniel
    Sarma Maruvada, P.
    Radiophysics and Quantum Electronics (English Translation of Izvestiya Vysshikh Uchebnykh Zavedenii, Radiofizika), 1980,
  • [23] Simulated analysis of lightning shielding failure performance of UHVAC transmission lines
    Yao, C. (yaochenguo@cqu.edu.cn), 2013, Science Press (39):
  • [24] RADIO INTERFERENCE FROM ISOLATED NOISE SOURCES ON OVERHEAD TRANSMISSION LINES
    WEDEPOHL, LM
    SAHA, JN
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1971, PA90 (05): : 2295 - &
  • [25] Radio Interference of Ultra HVDC Transmission Lines in High Altitude Region
    Yu, Zhanqing
    Zeng, Rong
    Li, Min
    Li, Ruihai
    Liu, Lei
    Yang, Dawei
    Zhang, Zheng
    Zhang, Bo
    Tian, Feng
    2010 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY & TECHNICAL EXHIBITION ON EMC RF/MICROWAVE MEASUREMENTS & INSTRUMENTATION, 2010, : 1672 - 1675
  • [26] Study on the radio interference of 750KV supervoltage transmission lines
    Zhang, L
    Liu, DH
    Wan, BQ
    Wu, X
    ASIA-PACIFIC CONFERENCE ON ENVIRONMENTAL ELECTROMAGNETICS, CEEM'2003, PROCEEDINGS, 2003, : 186 - 189
  • [27] Computation of Radio Interference Levels in High Voltage Transmission Lines with Corona
    Tejada, C.
    Gomez, P.
    Escamilla, J. C.
    IEEE LATIN AMERICA TRANSACTIONS, 2009, 7 (01) : 54 - 61
  • [28] Solving the issue of radio interference when deploying Digital Subscriber Lines
    Spruyt, P
    Braet, S
    BROADBAND ACCESS NETWORKS - NOC '97, 1997, : 98 - 105
  • [29] A METHOD FOR AVERAGING DISTANCE-FREQUENCY CHARACTERISTICS OF THE IONOSPHERE ON LONG-RANGE RADIO LINES
    BUBNOV, VA
    SAMOILOVA, NI
    GEOMAGNETIZM I AERONOMIYA, 1990, 30 (05): : 839 - 841
  • [30] Study of Identification of Shielding Failure and Back Striking in UHVAC Transmission Lines
    Shu Hong-chun
    Zhang Guang-bin
    Zhu Zi-zhao
    Zhu Sheng-qiang
    2009 INTERNATIONAL CONFERENCE ON SUSTAINABLE POWER GENERATION AND SUPPLY, VOLS 1-4, 2009, : 2670 - 2674