Electrical Bioimpedance-Based Monitoring of Intracochlear Tissue Changes After Cochlear Implantation

被引:0
|
作者
Sijgers, Leanne [1 ]
Geys, Marlies [1 ]
Geissler, Gunnar [2 ]
Boyle, Patrick [2 ]
Huber, Alexander [1 ]
Pfiffner, Flurin [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Dept Otorhinolaryngol Head & Neck Surg, CH-8091 Zurich, Switzerland
[2] Adv Bion GmbH, European Res Ctr, D-30625 Hannover, Germany
关键词
digital biomarkers; remote hearing healthcare; cochlear implant; neuroprosthetics; hearing technology; auditory rehabilitation; HEARING PRESERVATION; IMPEDANCE CHANGES; AUDITORY-NERVE; IN-VITRO; STIMULATION; ELECTRODES; MODEL; ELECTROCOCHLEOGRAPHY; OUTCOMES; HEALTH;
D O I
10.3390/s24237570
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: This study examined electrical bioimpedance as a biomarker for intracochlear tissue changes after cochlear implant surgery, comparing monopolar, three-point, and four-point impedance measurements over time and evaluating different measurement systems and approaches. Methods: Impedance measurements were obtained from 21 participants during surgery and at four postoperative stages. Monopolar impedances were recorded using the Bionic Ear Data Collection System (BEDCS) and the Active Insertion Monitoring (AIM) system. Three- and four-point impedances were recorded directly using BEDCS, and indirect three-point impedances were additionally derived from Electrical Field Imaging matrices recorded using BEDCS or AIM. Results: There was an 11% relative error between monopolar measurements from BEDCS and AIM and a 25% discrepancy between direct and indirect three-point measurements. Despite this, direct and indirect measurements from both systems were useful for tracking postoperative impedance shifts. Three- and four-point measurements showed a strong relationship both during and after surgery. Our results suggest that three- and four-point measurements are more specific than monopolar impedances in capturing localized tissue changes. Conclusions: Three- and four-point impedance measurements are potential markers of intracochlear tissue changes over time. While direct three-point impedance measurements offer higher accuracy, indirect measurements provide a feasible alternative for monitoring intracochlear changes in clinical settings lacking the option of direct measurements.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Individual Differences in Speech Recognition Changes After Cochlear Implantation
    Dornhoffer, James R.
    Reddy, Priyanka
    Meyer, Ted A.
    Schvartz-Leyzac, Kara C.
    Dubno, Judy R.
    McRackan, Theodore R.
    JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2021, 147 (03) : 280 - 286
  • [42] Analysis of a Cochlear Implant Database: Changes in Tinnitus Prevalence and Distress After Cochlear Implantation
    Assouly, Kelly K. S.
    Smit, Adriana L.
    Eikelboom, Robert H.
    Sucher, Cathy
    Atlas, Marcus
    Stokroos, Robert J.
    Stegeman, Inge
    TRENDS IN HEARING, 2022, 26
  • [43] Animal Models of Hearing Loss after Cochlear Implantation and Electrical Stimulation
    Reiss, Lina A. J.
    Kirk, Jonathon
    Claussen, Alexander D.
    Fallon, James B.
    HEARING RESEARCH, 2022, 426
  • [44] Soft Tissue Complications After Small Incision Pediatric Cochlear Implantation
    Davids, Taryn
    Ramsden, James D.
    Gordon, Karen A.
    James, Adrian L.
    Papsin, Blake C.
    LARYNGOSCOPE, 2009, 119 (05): : 980 - 983
  • [45] Novel Electrode Placement in Electrical Bioimpedance-Based Stroke Detection: Effects on Current Penetration and Injury Characterization in a Finite Element Model
    Bronk, Theodore S.
    Everitt, Alicia C.
    Murphy, Ethan K.
    Halter, Ryan J.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (05) : 1745 - 1757
  • [46] Value of Intracochlear Electrically Evoked Auditory Brainstem Response After Cochlear Implantation in Patients with Narrow Internal Auditory Canal
    Song, Mee Hyun
    Bae, Mi Ran
    Kim, Hee Nam
    Lee, Won-Sang
    Yang, Won Sun
    Choi, Jae Young
    LARYNGOSCOPE, 2010, 120 (08): : 1625 - 1631
  • [47] Loss of saccular function after cochlear implantation: The diagnostic impact of intracochlear electrically elicited vestibular evoked myogenic potentials
    Basta, D.
    Todt, I.
    Goepel, F.
    Ernst, A.
    AUDIOLOGY AND NEURO-OTOLOGY, 2008, 13 (03) : 187 - 192
  • [48] Fatigue-Induced Cole Electrical Impedance Model Changes of Biceps Tissue Bioimpedance
    Freeborn, Todd J.
    Fu, Bo
    FRACTAL AND FRACTIONAL, 2018, 2 (04) : 1 - 13
  • [49] Changes in Tinnitus after Cochlear Implantation and Its Relation with Psychological Functioning
    Kloostra, Francka J. J.
    Arnold, Rosemarie
    Hofman, Rutger
    Van Dijk, Pim
    AUDIOLOGY AND NEURO-OTOLOGY, 2015, 20 (02) : 81 - 89
  • [50] Changes in listening habits and quality of musical sound after cochlear implantation
    Lassaletta, Luis
    Castro, Alejandro
    Bastarrica, Marta
    Perez-Mora, Rosa
    Herran, Belen
    Sanz, Lorena
    de Sarria, M. Josefa
    Gavilan, Javier
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2008, 138 (03) : 363 - 367