Identification of Vortex-Induced Vibration on the Osman Gazi Suspension Bridge Tower and Mitigation by an Active Mass Damper

被引:1
|
作者
Inoue, Manabu [1 ]
Siringoringo, Dionysius M. [2 ]
Fujino, Yozo [3 ]
Koike, Yuji [4 ]
机构
[1] IHI Infrastruct Syst Co Ltd, 3 Ohama Nishi Machi,Sakai Ku, Sakai, Osaka 5900977, Japan
[2] Yokohama Natl Univ, Inst Multidisciplinary Sci, 79-1 Tokiwadai,Hodogaya Ku, Yokohama, Kanagawa 2408501, Japan
[3] YokohamaNat Univ, Inst Adv Sci, 79-1 Tokiwadai,Hodogaya Ku, Yokohama, Kanagawa 2408501, Japan
[4] IHI Corp, Corp R&D Div, 1 Shin Na Kahara Cho,Isogo Ku, Yokohama 2358501, Japan
关键词
Tower vortex-induced vibration; Active mass damper; Active control system; Long-span suspension bridge; Tower construction; Freestanding tower; MODEL;
D O I
10.1061/JBENF2.BEENG-7131
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper describes a study on identifying vortex-induced vibration (VIV) of the Osman Gazi Bridge tower during construction and in-service conditions and its control strategy using an active mass damper. In the wind tunnel tests conducted before bridge construction, tower VIV was identified in the first out-of-plane tower bending mode despite the presence of aerodynamic corner cuts on the tower cross section. Bridge towers are made of steel boxes with inherently low damping, resulting in a VIV amplitude exceeding the limits for the workability and safety required in the design specification. An active mass damper (AMD) was proposed to mitigate tower VIV during construction and in-service conditions. The investigations of tower aerodynamic characteristics related to VIV in wind tunnel tests, design considerations, and implementation of AMD in construction and in-service conditions are presented. Unlike active control systems on other long-span bridge towers that were removed after construction completion, the AMD systems on the Osman Gazi Bridge tower continue to function even after bridge construction completion. This makes the AMD on the Osman Gazi Bridge the world's first application of a full active control system on a long-span bridge tower for in-service conditions. The AMD system was found effective in controlling the vibration under both conditions by providing additional damping higher than the requirement in the design specification. The robustness and effectiveness of the active control system are demonstrated in a 1-year full observation of AMD performance via a structural monitoring system. In general, the RMS of tower VIV accelerations under AMD control is lower than 15 cm/s2 or approximately 50% smaller than the corresponding accelerations without AMD control.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Wind Tunnel Modeling for the Vortex-Induced Vibrations of a Yawed Bridge Tower
    Marra, Antonino Maria
    Mannini, Claudio
    Bartoli, Gianni
    JOURNAL OF BRIDGE ENGINEERING, 2017, 22 (05)
  • [42] Optimal design of tuned mass damper inerter with a Maxwell element for mitigating the vortex-induced vibration in bridges
    Dai, Jun
    Xu, Zhao-Dong
    Gai, Pan-Pan
    Hu, Zhong-Wei
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2021, 148
  • [43] Prediction analysis of vortex-induced vibration of long-span suspension bridge based on monitoring data
    Xu, Shiqiao
    Ma, Rujin
    Wang, Dalei
    Chen, Airong
    Tian, Hao
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2019, 191 : 312 - 324
  • [44] Cause investigation of high-mode vortex-induced vibration in a long-span suspension bridge
    Hwang, You Chan
    Kim, Sunjoong
    Kim, Ho-Kyung
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2020, 16 (01) : 84 - 93
  • [45] Vortex-Induced Vibration Performance and Mechanism Analysis of a Suspension Bridge Affected by Water-Filled Barriers
    Lang, Tianyi
    Wang, Hao
    Liu, Zhenqing
    Xu, Zidong
    Gao, Hui
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2024, 24 (16)
  • [46] Investigation on vortex-induced vibration of a suspension bridge using section and full aeroelastic wind tunnel tests
    Sun, Yanguo
    Li, Mingshui
    Liao, Haili
    WIND AND STRUCTURES, 2013, 17 (06) : 565 - 587
  • [47] Effects of railings on vortex-induced vibration of a bridge deck section
    Guan, Qing-Hai
    Li, Jia-Wu
    Hu, Zhao-Tong
    Liu, Jian-Xin
    Zhendong yu Chongji/Journal of Vibration and Shock, 2014, 33 (03): : 150 - 156
  • [48] Vibration mitigation of Shazand Railway Bridge induced by train using tuned mass damper (TMD)
    School of Civil Engineering, Shiraz University of Technology, Shiraz, Iran
    不详
    Period Polytech Mech Eng, 4 (189-198):
  • [49] CONTROL PERFORMANCE AND LAYOUT OPTIMIZATION OF MULTIPLE MODE VORTEX-INDUCED VIBRATION USING TUNED MASS DAMPER FOR LONG-SPAN CONTINUOUS BRIDGE
    Xu S.-Y.
    Fang G.-S.
    Zhang M.-J.
    Øiseth O.
    Ge Y.-J.
    Gongcheng Lixue/Engineering Mechanics, 2024, 41 : 23 - 30
  • [50] Vortex-induced vibration of a water tank tower with small aspect ratio
    Ruscheweyh, H
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2001, 89 (14-15) : 1579 - 1589