Identification of Vortex-Induced Vibration on the Osman Gazi Suspension Bridge Tower and Mitigation by an Active Mass Damper

被引:1
|
作者
Inoue, Manabu [1 ]
Siringoringo, Dionysius M. [2 ]
Fujino, Yozo [3 ]
Koike, Yuji [4 ]
机构
[1] IHI Infrastruct Syst Co Ltd, 3 Ohama Nishi Machi,Sakai Ku, Sakai, Osaka 5900977, Japan
[2] Yokohama Natl Univ, Inst Multidisciplinary Sci, 79-1 Tokiwadai,Hodogaya Ku, Yokohama, Kanagawa 2408501, Japan
[3] YokohamaNat Univ, Inst Adv Sci, 79-1 Tokiwadai,Hodogaya Ku, Yokohama, Kanagawa 2408501, Japan
[4] IHI Corp, Corp R&D Div, 1 Shin Na Kahara Cho,Isogo Ku, Yokohama 2358501, Japan
关键词
Tower vortex-induced vibration; Active mass damper; Active control system; Long-span suspension bridge; Tower construction; Freestanding tower; MODEL;
D O I
10.1061/JBENF2.BEENG-7131
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper describes a study on identifying vortex-induced vibration (VIV) of the Osman Gazi Bridge tower during construction and in-service conditions and its control strategy using an active mass damper. In the wind tunnel tests conducted before bridge construction, tower VIV was identified in the first out-of-plane tower bending mode despite the presence of aerodynamic corner cuts on the tower cross section. Bridge towers are made of steel boxes with inherently low damping, resulting in a VIV amplitude exceeding the limits for the workability and safety required in the design specification. An active mass damper (AMD) was proposed to mitigate tower VIV during construction and in-service conditions. The investigations of tower aerodynamic characteristics related to VIV in wind tunnel tests, design considerations, and implementation of AMD in construction and in-service conditions are presented. Unlike active control systems on other long-span bridge towers that were removed after construction completion, the AMD systems on the Osman Gazi Bridge tower continue to function even after bridge construction completion. This makes the AMD on the Osman Gazi Bridge the world's first application of a full active control system on a long-span bridge tower for in-service conditions. The AMD system was found effective in controlling the vibration under both conditions by providing additional damping higher than the requirement in the design specification. The robustness and effectiveness of the active control system are demonstrated in a 1-year full observation of AMD performance via a structural monitoring system. In general, the RMS of tower VIV accelerations under AMD control is lower than 15 cm/s2 or approximately 50% smaller than the corresponding accelerations without AMD control.
引用
收藏
页数:17
相关论文
共 50 条
  • [11] The damping efficiency of vortex-induced vibration by tuned-mass damper of a tower-supported steel stack
    Homma, Shin
    Maeda, Junji
    Hanada, Naoya
    WIND AND STRUCTURES, 2009, 12 (04) : 333 - 345
  • [12] Vibration control of vortex-induced vibrations of a bridge deck by a single-side pounding tuned mass damper
    Wang, Wenxi
    Wang, Xiuyong
    Hua, Xugang
    Song, Gangbing
    Chen, Zhengqing
    ENGINEERING STRUCTURES, 2018, 173 : 61 - 75
  • [13] Deep learning-based automated identification on vortex-induced vibration of long suspenders for the suspension bridge
    Su, Xun
    Mao, Jianxiao
    Wang, Hao
    Gao, Hui
    Li, Dan
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2025, 224
  • [14] Field monitoring and control for vortex-induced vibration of hanger cables in suspension bridge
    Gao, Hui
    Wang, Hao
    Mao, Jianxiao
    Guo, Xiaoming
    Su, Xun
    Lepidi, Marco
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2024, 248
  • [15] Parameter determination of the tuned mass damper mitigating the vortex-induced vibration in bridges
    Dai, Jun
    Xu, Zhao-Dong
    Gai, Pan-Pan
    ENGINEERING STRUCTURES, 2020, 221 (221)
  • [16] Monitoring, intelligent perception, and early warning of vortex-induced vibration of suspension bridge
    Dan, Danhui
    Li, Houjin
    STRUCTURAL CONTROL & HEALTH MONITORING, 2022, 29 (05):
  • [17] Vortex-Induced Vibration and Countermeasure of a Tubular Transmission Tower
    Fu, Xing
    Jiang, Yao
    Li, Hong-Nan
    Li, Jia-Xiang
    Xie, Wen-Ping
    Yang, Li-Dong
    Zhang, Jian
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2021, 21 (12)
  • [18] Mitigation Measures Research of Vortex-Induced Vibration of the Forth Nanjing Yangzi River Bridge
    Ding, Jing
    Liao, Haili
    STRUCTURAL ENGINEERING, VIBRATION AND AEROSPACE ENGINEERING, 2014, 482 : 242 - 247
  • [19] Mitigation of Vortex-Induced Vibration in Bridges Using Semiactive Tuned Mass Dampers
    Dai, Jun
    Xu, Zhao-Dong
    Gai, Pan-Pan
    Xu, Yan-Wei
    JOURNAL OF BRIDGE ENGINEERING, 2021, 26 (06)
  • [20] Vertical Vortex-Induced Vibration Control Effect of MTMDs in Suspension Bridge and Parameter Optimization
    Chen Y.
    Yuan R.
    Wang Z.
    Bridge Construction, 2024, 54 (02) : 77 - 83