Identification of Vortex-Induced Vibration on the Osman Gazi Suspension Bridge Tower and Mitigation by an Active Mass Damper

被引:1
|
作者
Inoue, Manabu [1 ]
Siringoringo, Dionysius M. [2 ]
Fujino, Yozo [3 ]
Koike, Yuji [4 ]
机构
[1] IHI Infrastruct Syst Co Ltd, 3 Ohama Nishi Machi,Sakai Ku, Sakai, Osaka 5900977, Japan
[2] Yokohama Natl Univ, Inst Multidisciplinary Sci, 79-1 Tokiwadai,Hodogaya Ku, Yokohama, Kanagawa 2408501, Japan
[3] YokohamaNat Univ, Inst Adv Sci, 79-1 Tokiwadai,Hodogaya Ku, Yokohama, Kanagawa 2408501, Japan
[4] IHI Corp, Corp R&D Div, 1 Shin Na Kahara Cho,Isogo Ku, Yokohama 2358501, Japan
关键词
Tower vortex-induced vibration; Active mass damper; Active control system; Long-span suspension bridge; Tower construction; Freestanding tower; MODEL;
D O I
10.1061/JBENF2.BEENG-7131
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper describes a study on identifying vortex-induced vibration (VIV) of the Osman Gazi Bridge tower during construction and in-service conditions and its control strategy using an active mass damper. In the wind tunnel tests conducted before bridge construction, tower VIV was identified in the first out-of-plane tower bending mode despite the presence of aerodynamic corner cuts on the tower cross section. Bridge towers are made of steel boxes with inherently low damping, resulting in a VIV amplitude exceeding the limits for the workability and safety required in the design specification. An active mass damper (AMD) was proposed to mitigate tower VIV during construction and in-service conditions. The investigations of tower aerodynamic characteristics related to VIV in wind tunnel tests, design considerations, and implementation of AMD in construction and in-service conditions are presented. Unlike active control systems on other long-span bridge towers that were removed after construction completion, the AMD systems on the Osman Gazi Bridge tower continue to function even after bridge construction completion. This makes the AMD on the Osman Gazi Bridge the world's first application of a full active control system on a long-span bridge tower for in-service conditions. The AMD system was found effective in controlling the vibration under both conditions by providing additional damping higher than the requirement in the design specification. The robustness and effectiveness of the active control system are demonstrated in a 1-year full observation of AMD performance via a structural monitoring system. In general, the RMS of tower VIV accelerations under AMD control is lower than 15 cm/s2 or approximately 50% smaller than the corresponding accelerations without AMD control.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Experimental Study on Vortex-Induced Vibration of Large-Span Pedestrian Suspension Bridge
    Li Y.
    Ma C.
    Li H.
    Tian Y.
    Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2022, 42 (03): : 483 - 489
  • [22] A Multi-Degree of Freedom Tuned Mass Damper Design for Vibration Mitigation of a Suspension Bridge
    Meng, Fanhao
    Wan, Jiancheng
    Xia, Yongjun
    Ma, Yong
    Yu, Jingjun
    APPLIED SCIENCES-BASEL, 2020, 10 (02):
  • [23] Mitigation effect of guide vanes on the vortex-induced vibration of a long-span closed-box girder suspension bridge
    Li, Ming
    Yang, Xiongwei
    Zhang, Haicheng
    Zhang, Hao
    Zhang, Tianyi
    Li, Mingshui
    JOURNAL OF VIBRATION AND CONTROL, 2024,
  • [24] Experimental study on damping performance of a pounding tuned mass damper to vibration suppression of vortex-induced vibration
    Yang, Wanli
    Yang, Sijie
    Zhang, Zhichao
    Wang, Ning
    Song, Gangbing
    OCEAN ENGINEERING, 2022, 249
  • [25] Vortex-Induced Vibration of a Tall Bridge Tower with Four Columns and the Wake Effects on the Nearby Suspenders
    Fang, Chen
    Wang, Zewen
    Tang, Haojun
    Li, Yongle
    Deng, Zhouquan
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2020, 20 (09)
  • [26] Vortex-induced vibration of suspenders in the wake of bridge tower by numerical simulation and wind tunnel test
    Li, Yongle
    Tang, Haojun
    Lin, Qiaoman
    Chen, Xinzhong
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2017, 164 : 164 - 173
  • [27] Automatic Identification of Bridge Vortex-Induced Vibration Using Random Decrement Method
    Huang, Zhiwen
    Li, Yanzhe
    Hua, Xugang
    Chen, Zhengqing
    Wen, Qing
    APPLIED SCIENCES-BASEL, 2019, 9 (10):
  • [28] EFFECTS OF GEOMETRICAL SHAPE ON VORTEX-INDUCED OSCILLATIONS OF BRIDGE TOWER
    TAKEUCHI, T
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1990, 33 (1-2) : 359 - 368
  • [29] ANALYSIS OF VORTEX-INDUCED VIBRATION CHARACTERISTICS OF XIHOUMEN BRIDGE
    Guo J.
    Zhong C.-J.
    Wu J.-Y.
    Ma K.-J.
    Weng B.-W.
    Xiao C.-L.
    Gongcheng Lixue/Engineering Mechanics, 2023, 40 : 39 - 45
  • [30] An overview of vortex-induced vibration (VIV) of bridge decks
    Wu T.
    Kareem A.
    Frontiers of Structural and Civil Engineering, 2012, 6 (4) : 335 - 347