Optimization of subcellular boron distribution measurement using UV-C imprint and neutron autoradiography in boron neutron capture therapy

被引:2
|
作者
Wu, Yan [1 ]
Shu, Diyun [2 ]
Geng, Changran [1 ]
Postuma, Ian [3 ]
Tang, Xiaobin [1 ]
Liu, Yuan-Hao [1 ,2 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Dept Nucl Sci & Technol, Nanjing 210016, Jiangsu, Peoples R China
[2] Neuboron Therapy Syst Ltd, Xiamen 361000, Fujian, Peoples R China
[3] INFN, Natl Inst Nucl Phys, Unit Pavia, I-27100 Pavia, Italy
基金
中国国家自然科学基金;
关键词
Subcellular boron distribution; Boron neutron capture therapy; Neutron autoradiography; PADC; UV-C imprint; CELLS; ALPHA; SENSITIZATION; IRRADIATION;
D O I
10.1016/j.radmeas.2024.107351
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The subcellular distribution of boron drugs is crucial for studying radiobiological effects and microdosimetry in boron neutron capture therapy (BNCT). Accurately measuring this distribution remains a key objective. Building on the neutron autoradiography method combined with UV-C sensitization, this study aims to further optimize the approach and implement it at the BNCT center of Xiamen Humanity Hospital, with the expectation of applying it to future boron drug development. A dedicated irradiation device for neutron autoradiography was developed based on a clinical epithermal neutron beam. Optimal conditions for etching and UV-C cell imprints were investigated. After U251 cells were incubated with L-4-boronophenylalanin (BPA), cell imprints and track images were obtained under optimal conditions, and track distributions within cell structure were evaluated. The optimal etching condition involved using Potassium-Ethanol-Water (PEW) solution for 10 min, yielding track diameters of approximately 1 mu m. After the poly allyl diglycol carbonate (PADC) with cultured cells was exposed to UV-C for 12 h, a clear cellular structure was imprinted on the PADC. The coupled track and cell structure images suggest that BPA may concentrate more around the U251 cell nucleus. The results demonstrate that the improved method can clearly distinguish tracks within the nucleus and cytoplasm in two-dimensional projections, enabling a more accurate evaluation of boron distribution at the subcellular scale.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Boron neutron capture therapy (BNCT):: Implications of neutron beam and boron compound characteristics
    Wheeler, FJ
    Nigg, DW
    Capala, J
    Watkins, PRD
    Vroegindeweij, C
    Auterinen, I
    Seppälä, T
    Bleuel, D
    MEDICAL PHYSICS, 1999, 26 (07) : 1237 - 1244
  • [42] Optimization of epithermal neutron field for cyclotron-based boron neutron capture therapy
    Yonai, S
    Aoki, T
    Nakamura, T
    Yashima, H
    Baba, M
    Yokohori, H
    Tahara, Y
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 299 - 303
  • [43] Encapsulation of boron in lipiodol for boron neutron capture therapy of hepatoma
    Chou, FI
    Wei, YY
    Jeang, SJ
    Wang, TK
    Kai, JJ
    Chi, CW
    Lui, WY
    ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 : B101 - B107
  • [44] Boron Neutron Capture Therapy: Microdosimetry at Different Boron Concentrations
    Conte, Valeria
    Bianchi, Anna
    Selva, Anna
    APPLIED SCIENCES-BASEL, 2024, 14 (01):
  • [45] A STOCHASTIC-MODEL FOR SUBCELLULAR DOSIMETRY IN BORON NEUTRON-CAPTURE THERAPY
    CEBERG, CP
    PERSSON, A
    BRUN, A
    HUISKAMP, R
    SALFORD, LG
    PERSSON, BRR
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11): : 1819 - 1830
  • [46] Development of a Clinical Neutron Source for Boron Neutron Capture Therapy
    Lee, C.
    Venchi, G.
    Dunaevsky, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 114 (03): : E536 - E536
  • [47] Design of the neutron generator for the development of boron neutron capture therapy
    Bezshyyko, Oleg
    Golinka-Bezshyyko, Larysa
    BIO-ALGORITHMS AND MED-SYSTEMS, 2023, 19 (01) : 124 - 131
  • [48] NEUTRON SPECTROMETRY AND DOSIMETRY FOR BORON NEUTRON-CAPTURE THERAPY
    PERKS, CA
    GIBSON, JAB
    RADIATION PROTECTION DOSIMETRY, 1992, 44 (1-4) : 425 - 428
  • [49] Study of epithermal neutron columns for boron neutron capture therapy
    Oka, Y
    Akiyama, M
    An, S
    PROGRESS IN NUCLEAR ENERGY, 1998, 32 (1-2) : 61 - 70
  • [50] The neutron sensitivity of dosimeters applied to boron neutron capture therapy
    Raaijmakers, CPJ
    Watkins, PRD
    Nottelman, EL
    Verhagen, HW
    Jansen, JTM
    Zoetelief, J
    Mijnheer, BJ
    MEDICAL PHYSICS, 1996, 23 (09) : 1581 - 1589