Optimization of subcellular boron distribution measurement using UV-C imprint and neutron autoradiography in boron neutron capture therapy

被引:2
|
作者
Wu, Yan [1 ]
Shu, Diyun [2 ]
Geng, Changran [1 ]
Postuma, Ian [3 ]
Tang, Xiaobin [1 ]
Liu, Yuan-Hao [1 ,2 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Dept Nucl Sci & Technol, Nanjing 210016, Jiangsu, Peoples R China
[2] Neuboron Therapy Syst Ltd, Xiamen 361000, Fujian, Peoples R China
[3] INFN, Natl Inst Nucl Phys, Unit Pavia, I-27100 Pavia, Italy
基金
中国国家自然科学基金;
关键词
Subcellular boron distribution; Boron neutron capture therapy; Neutron autoradiography; PADC; UV-C imprint; CELLS; ALPHA; SENSITIZATION; IRRADIATION;
D O I
10.1016/j.radmeas.2024.107351
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The subcellular distribution of boron drugs is crucial for studying radiobiological effects and microdosimetry in boron neutron capture therapy (BNCT). Accurately measuring this distribution remains a key objective. Building on the neutron autoradiography method combined with UV-C sensitization, this study aims to further optimize the approach and implement it at the BNCT center of Xiamen Humanity Hospital, with the expectation of applying it to future boron drug development. A dedicated irradiation device for neutron autoradiography was developed based on a clinical epithermal neutron beam. Optimal conditions for etching and UV-C cell imprints were investigated. After U251 cells were incubated with L-4-boronophenylalanin (BPA), cell imprints and track images were obtained under optimal conditions, and track distributions within cell structure were evaluated. The optimal etching condition involved using Potassium-Ethanol-Water (PEW) solution for 10 min, yielding track diameters of approximately 1 mu m. After the poly allyl diglycol carbonate (PADC) with cultured cells was exposed to UV-C for 12 h, a clear cellular structure was imprinted on the PADC. The coupled track and cell structure images suggest that BPA may concentrate more around the U251 cell nucleus. The results demonstrate that the improved method can clearly distinguish tracks within the nucleus and cytoplasm in two-dimensional projections, enabling a more accurate evaluation of boron distribution at the subcellular scale.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Boron neutron capture therapy in oncology
    Gabel, D
    CHEMIE IN UNSERER ZEIT, 1997, 31 (05) : 235 - 240
  • [32] BORON NEUTRON-CAPTURE THERAPY
    MORRIS, JH
    CHEMISTRY IN BRITAIN, 1991, 27 (04) : 331 - 334
  • [33] Boron and gadolinium neutron capture therapy
    C. Salt
    A. J. Lennox
    M. Takagaki
    J. A. Maguire
    N. S. Hosmane
    Russian Chemical Bulletin, 2004, 53 : 1871 - 1888
  • [34] Boron agents for neutron capture therapy
    Hu, Kuan
    Yang, Zhimin
    Zhang, Lingling
    Xie, Lin
    Wang, Lu
    Xu, Hao
    Josephson, Lee
    Liang, Steven H.
    Zhang, Ming-Rong
    COORDINATION CHEMISTRY REVIEWS, 2020, 405
  • [35] PSEUDOPROGRESSION IN BORON NEUTRON CAPTURE THERAPY
    Miyatake, Shin-Ichi
    Kawabata, Shinji
    Nonoguchi, Naosuke
    Kuroiwa, Toshihiko
    Ono, Koji
    NEURO-ONCOLOGY, 2009, 11 (06) : 915 - 915
  • [36] Compounds for boron neutron capture therapy
    Gabel, D
    CHIMICA OGGI-CHEMISTRY TODAY, 1996, 14 (10) : 37 - 42
  • [37] Boron neutron capture therapy for glioblastoma
    Yamamoto, Tetsuya
    Nakai, Kei
    Matsumura, Akira
    CANCER LETTERS, 2008, 262 (02) : 143 - 152
  • [38] Optimization of Boron-10 Concentration in Cancerous Tumors for Boron Neutron Capture Therapy Using a Mixture of Boron Agents
    El Malky, T. A.
    El Ghazaly, M.
    Eghawry, A. El-M
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2012, 45 (04): : 144 - 151
  • [39] Dose optimization of extended collimators in boron neutron capture therapy
    Zhu, Yadi
    Lian, Chao
    Ji, Xiang
    Zhang, Xiaoxiang
    Li, Chunjing
    Bai, Yunqing
    Gao, Jun
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2025, 11 (01):
  • [40] Investigation of the neutron spectrum measurement method for dose evaluation in boron neutron capture therapy
    Onishi, T.
    Kumada, H.
    Takada, K.
    Naito, F.
    Kurihara, T.
    Sakae, T.
    APPLIED RADIATION AND ISOTOPES, 2018, 140 : 5 - 11