Properties analysis on interlayer within lithium target and its beam uniformity for accelerator-based Boron Neutron Capture Therapy

被引:0
|
作者
Hu, Yaocheng [1 ,2 ]
Jiang, Quanxu [1 ,2 ]
Xie, Yupeng [1 ,2 ]
Su, Haoquan [1 ,2 ]
Zhang, Fanxi [1 ,2 ]
Sun, Qiuyu [1 ,2 ]
Li, Jinglun [1 ,2 ]
Yang, Yifan [1 ,2 ]
Si, Yixin [1 ,2 ]
Li, Haipeng [1 ,2 ]
Ma, Baolong [1 ,2 ]
Li, Zhi feng [1 ,2 ]
Wang, Sheng [1 ,2 ,3 ,4 ]
机构
[1] Xi An Jiao Tong Univ, Sch Nucl Sci & Technol, Sch Energy & Power Engn, 28 Xianning West Rd, Xian 710049, Shaanxi, Peoples R China
[2] Sci Valley Medium Sized Bldg 1, Huzhou 313000, Zhejiang, Peoples R China
[3] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Shaanxi, Peoples R China
[4] HBNCT Co Ltd, Hangzhou 310000, Zhejiang, Peoples R China
来源
JOURNAL OF INSTRUMENTATION | 2024年 / 19卷 / 09期
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Targets (spallation source targets; radioisotope production; neutrino and muon sources); Accelerator Applications; Instrumentation for neutron sources; LI-7(P; N)BE-7; REACTION; IN-SITU; THICKNESS; SYSTEM;
D O I
10.1088/1748-0221/19/09/P09002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In order to enhance the performance and lifetime of the lithium target used in accelerator- based neutron sources for Boron Neutron Capture Therapy (BNCT) treatment, an exploration of target design was conducted based on the 2.8 MeV, 20 mA proton beam. A comparison between scanning magnets and octupole magnets was performed for beam uniform, with octupole magnets selected to effectively avoid localized high thermal densities over short durations. Exploration was conducted on the performance of tantalum and vanadium as interlayers within the lithium target, considering aspects such as cooling, hydrogen diffusion, and neutron performances. This study revealed that, as the majority of energy deposition occurs within the interlayer, the presence of an appropriately thick tantalum or vanadium interlayer has minimal impact on cooling effectiveness, ensuring temperatures remain below 144 degree celsius. The addition of an interlayer effectively reduces the maximum hydrogen concentration in copper, thus preventing copper blistering. Within the investigated thickness range, the interlayer does not affect neutron spectrum in the forward direction of the target, mitigating concerns regarding its impact on beam shaping.
引用
收藏
页数:26
相关论文
共 50 条
  • [41] High power accelerator-based boron neutron capture with a liquid lithium target and new applications to treatment of infectious diseases
    Halfon, S.
    Paul, M.
    Steinberg, D.
    Nagler, A.
    Arenshtam, A.
    Kijel, D.
    Polacheck, I.
    Srebnik, M.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : S278 - S281
  • [42] Design of an accelerator-based neutron source for neutron capture therapy
    Terlizzi, R.
    Colonna, N.
    Colangelo, P.
    Maiorana, A.
    Marrone, S.
    Raino, A.
    Tagliente, G.
    Variale, V.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : S292 - S295
  • [43] Characterization of Be Deposits on Mo, W and Cu Substrates, to Implement in a Neutron Production Target for Accelerator-based Boron Neutron Capture Therapy
    Suarez Anzorena, M.
    Gagetti, L.
    del Grosso, M. F.
    Kreiner, A. J.
    INTERNATIONAL CONGRESS OF SCIENCE AND TECHNOLOGY OF METALLURGY AND MATERIALS, SAM - CONAMET 2013, 2015, 8 : 471 - 477
  • [44] Implications of radiation microdosimetry for accelerator-based boron neutron capture therapy: a radiobiological perspective
    Fukunaga, Hisanori
    Matsuya, Yusuke
    Tokuuye, Koichi
    Omura, Motoko
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1111):
  • [45] Experimental verification of in-phantom calculations for an accelerator-based neutron source for boron neutron capture therapy
    Dobelbower, MC
    Vest, A
    Reed, MJ
    Blue, TE
    MEDICAL PHYSICS, 1999, 26 (03) : 376 - 380
  • [46] A NEUTRONIC STUDY OF AN ACCELERATOR-BASED NEUTRON-IRRADIATION FACILITY FOR BORON NEUTRON-CAPTURE THERAPY
    WANG, CKC
    BLUE, TE
    GAHBAUER, R
    NUCLEAR TECHNOLOGY, 1989, 84 (01) : 93 - 107
  • [47] Development of a high-power water cooled beryllium target for use in accelerator-based boron neutron capture therapy
    Blackburn, BW
    Yanch, JC
    Klinkowstein, RE
    MEDICAL PHYSICS, 1998, 25 (10) : 1967 - 1974
  • [48] Development and application of neutron field optimization parameters for an accelerator-based neutron source for boron neutron capture therapy
    Woollard, JE
    Blue, TE
    Gupta, N
    Gahbauer, RA
    NUCLEAR TECHNOLOGY, 1996, 115 (01) : 100 - 113
  • [49] Boron neutron capture therapy in the new age of accelerator-based neutron production and preliminary progress in Canada
    Dziura, Dominik
    Tabbassum, Sana
    MacNeil, Amanda
    Maharaj, Dalini D.
    Laxdal, Robert
    Kester, Oliver
    Pan, Ming
    Kumada, Hiroaki
    Marquardt, Drew
    CANADIAN JOURNAL OF PHYSICS, 2023, 101 (08) : 363 - 372
  • [50] Lithium neutron producing target for BINP accelerator-based neutron source
    Bayanov, B
    Belov, V
    Kindyuk, V
    Oparin, E
    Taskaev, S
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) : 817 - 821