Boron neutron capture therapy in the new age of accelerator-based neutron production and preliminary progress in Canada

被引:7
|
作者
Dziura, Dominik [1 ]
Tabbassum, Sana [2 ]
MacNeil, Amanda [1 ]
Maharaj, Dalini D. [1 ,3 ]
Laxdal, Robert [3 ]
Kester, Oliver [3 ]
Pan, Ming [4 ,5 ,6 ]
Kumada, Hiroaki [7 ]
Marquardt, Drew [1 ,4 ]
机构
[1] Univ Windsor, Dept Chem & Biochem, Windsor, ON, Canada
[2] Purdue Univ, Sch Hlth Sci, W Lafayette, IN 47906 USA
[3] TRIUMF, Accelerator Div, Vancouver, BC, Canada
[4] Univ Windsor, Dept Phys, Windsor, ON, Canada
[5] Windsor Reg Hosp, Radiat Oncol, Windsor, ON, Canada
[6] Western Univ, Schulich Sch Med & Dent, London, ON, Canada
[7] Univ Tsukuba, Proton Med Res Ctr, Tsukuba, Japan
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
accelerator-based neutron production; boron neutron capture therapy (BNCT); cancer therapy; cancer; compact accelerator neutron source (CANS); BNCT FACILITY; PARTICLE; BRAIN; RADIOTHERAPY; HISTORY; CANCER; BEAM; NCT;
D O I
10.1139/cjp-2022-0266
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Each year more than 3000 Canadians are diagnosed with brain cancers like glioblastoma multiforme or recurrent head and neck cancers, which are difficult to treat with conventional radiotherapy techniques. One of the most clinically promising treatments for these cancers is boron neutron capture therapy (BNCT). This procedure involves selectively introducing a boron delivery agent into tumor cells and irradiating them with a neutron beam, which kills the cancer cells due to the high-linear energy transfer radiation produced by the 10B(n,& alpha; )7Li capture reaction. The theory of BNCT has been around for a long time since 1936, but has historically been limited by poor boron delivery agents and non-optimal neutron source facilities. Although significant improvements have been made in both of these domains, it is mainly the advancements of accelerator-based neutron sources that have led to the expansion of over 20 new BNCT facilities worldwide in the past decade. Additionally in this work, particle and heavy ion transport code system simulations, in collaboration with the University of Tsukuba, were performed to examine the effectiveness of the Ibaraki BNCT beam shaping assembly to moderate a neutron beam suitable for BNCT at the proposed prototype Canadian compact accelerator-based neutron source (CANS) site, which uses a similar but slightly higher energy 10 MeV proton accelerator with a 1 mA average current. The advancements of CANSs in recent decades have enabled significant improvements in BNCT technologies, allowing it to become a more viable clinical treatment option.
引用
收藏
页码:363 / 372
页数:10
相关论文
共 50 条
  • [1] Accelerator-based neutron source for boron neutron capture therapy
    Ivanov, A. A.
    Smirnov, A. N.
    Taskaev, S. Yu
    Bayanov, B. F.
    Belchenko, Yu, I
    Davydenko, V., I
    Dunaevsky, A.
    Emelev, I. S.
    Kasatov, D. A.
    Makarov, A. N.
    Meekins, M.
    Kuksanov, N. K.
    Popov, S. S.
    Salimov, R. A.
    Sanin, A. L.
    Sorokin, I. N.
    Sycheva, T., V
    Shudlo, I. M.
    Vorob'ev, D. S.
    Cherepkov, V. G.
    Fadeev, S. N.
    PHYSICS-USPEKHI, 2022, 65 (08) : 834 - 851
  • [2] Designing accelerator-based epithermal neutron beams for boron neutron capture therapy
    Bleuel, DL
    Donahue, RJ
    Ludewigt, BA
    Vujic, J
    MEDICAL PHYSICS, 1998, 25 (09) : 1725 - 1734
  • [3] Development of an Accelerator-Based Epithermal Neutron Source for Boron Neutron Capture Therapy
    S. Yu. Taskaev
    Physics of Particles and Nuclei, 2019, 50 : 569 - 575
  • [4] A shielding design for an accelerator-based neutron source for boron neutron capture therapy
    Hawk, AE
    Blue, TE
    Woollard, JE
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) : 1027 - 1031
  • [5] Development of an Accelerator-Based Epithermal Neutron Source for Boron Neutron Capture Therapy
    Taskaev, S. Yu.
    PHYSICS OF PARTICLES AND NUCLEI, 2019, 50 (05) : 569 - 575
  • [6] Treatment Planning for Accelerator-Based Boron Neutron Capture Therapy
    Herrera, Maria S.
    Gonzalez, Sara J.
    Minsky, Daniel M.
    Kreiner, Andres J.
    VIII LATIN AMERICAN SYMPOSIUM ON NUCLEAR PHYSICS AND APPLICATIONS, 2010, 1265 : 451 - 452
  • [7] Design for an accelerator-based orthogonal epithermal neutron beam for boron neutron capture therapy
    Allen, DA
    Beynon, TD
    Green, S
    MEDICAL PHYSICS, 1999, 26 (01) : 71 - 76
  • [8] Opportunities for Using an Accelerator-Based Epithermal Neutron Source for Boron Neutron Capture Therapy
    Taskaev S.Y.
    Kanygin V.V.
    Byvaltsev V.A.
    Zaboronok A.A.
    Volkova O.Y.
    Mechetina L.V.
    Taranin A.V.
    Kichigin A.I.
    Iarullina A.I.
    Eliseenko I.A.
    Nakai K.
    Sato E.
    Yamamoto T.
    Ishikawa E.
    Matsumura A.
    Biomedical Engineering, 2018, 52 (02) : 73 - 76
  • [9] First experiments on neutron detection on the accelerator-based source for boron neutron capture therapy
    A. S. Kuznetsov
    G. N. Malyshkin
    A. N. Makarov
    I. N. Sorokin
    Yu. S. Sulyaev
    S. Yu. Taskaev
    Technical Physics Letters, 2009, 35 : 346 - 348
  • [10] Neutron beam design and dosimetric evaluation for accelerator-based Boron Neutron Capture Therapy
    Bortolussi, S.
    Postuma, I.
    Protti, N.
    Fatemi, S.
    Magni, C.
    Gonzalez, S.
    Altieri, S.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1024 - S1024