Properties analysis on interlayer within lithium target and its beam uniformity for accelerator-based Boron Neutron Capture Therapy

被引:0
|
作者
Hu, Yaocheng [1 ,2 ]
Jiang, Quanxu [1 ,2 ]
Xie, Yupeng [1 ,2 ]
Su, Haoquan [1 ,2 ]
Zhang, Fanxi [1 ,2 ]
Sun, Qiuyu [1 ,2 ]
Li, Jinglun [1 ,2 ]
Yang, Yifan [1 ,2 ]
Si, Yixin [1 ,2 ]
Li, Haipeng [1 ,2 ]
Ma, Baolong [1 ,2 ]
Li, Zhi feng [1 ,2 ]
Wang, Sheng [1 ,2 ,3 ,4 ]
机构
[1] Xi An Jiao Tong Univ, Sch Nucl Sci & Technol, Sch Energy & Power Engn, 28 Xianning West Rd, Xian 710049, Shaanxi, Peoples R China
[2] Sci Valley Medium Sized Bldg 1, Huzhou 313000, Zhejiang, Peoples R China
[3] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Shaanxi, Peoples R China
[4] HBNCT Co Ltd, Hangzhou 310000, Zhejiang, Peoples R China
来源
JOURNAL OF INSTRUMENTATION | 2024年 / 19卷 / 09期
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Targets (spallation source targets; radioisotope production; neutrino and muon sources); Accelerator Applications; Instrumentation for neutron sources; LI-7(P; N)BE-7; REACTION; IN-SITU; THICKNESS; SYSTEM;
D O I
10.1088/1748-0221/19/09/P09002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In order to enhance the performance and lifetime of the lithium target used in accelerator- based neutron sources for Boron Neutron Capture Therapy (BNCT) treatment, an exploration of target design was conducted based on the 2.8 MeV, 20 mA proton beam. A comparison between scanning magnets and octupole magnets was performed for beam uniform, with octupole magnets selected to effectively avoid localized high thermal densities over short durations. Exploration was conducted on the performance of tantalum and vanadium as interlayers within the lithium target, considering aspects such as cooling, hydrogen diffusion, and neutron performances. This study revealed that, as the majority of energy deposition occurs within the interlayer, the presence of an appropriately thick tantalum or vanadium interlayer has minimal impact on cooling effectiveness, ensuring temperatures remain below 144 degree celsius. The addition of an interlayer effectively reduces the maximum hydrogen concentration in copper, thus preventing copper blistering. Within the investigated thickness range, the interlayer does not affect neutron spectrum in the forward direction of the target, mitigating concerns regarding its impact on beam shaping.
引用
收藏
页数:26
相关论文
共 50 条
  • [31] Mixed-field dosimetry measurement of a target assembly for an accelerator-based neutron source for boron neutron capture therapy
    Reed, MK
    Dobelbower, MC
    Woollard, JE
    Blue, TE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 419 (01): : 160 - 166
  • [32] Mixed-field dosimetry measurement of a target assembly for an accelerator-based neutron source for boron neutron capture therapy
    Ohio State Univ, Columbus, OH, United States
    Nucl Instrum Methods Phys Res Sect A, 1 (160-166):
  • [33] Accelerator-based boron neutron capture therapy facility at the Helsinki University Hospital
    Porra, Liisa
    Seppala, Tiina
    Wendland, Lauri
    Revitzer, Hannu
    Joensuu, Heikki
    Eide, Paul
    Koivunoro, Hanna
    Smick, Noah
    Smick, Theodore
    Tenhunen, Mikko
    ACTA ONCOLOGICA, 2022, 61 (02) : 269 - 273
  • [34] A DESIGN STUDY OF AN ACCELERATOR-BASED EPITHERMAL NEUTRON SOURCE FOR BORON NEUTRON-CAPTURE THERAPY
    WANG, CKC
    BLUE, TE
    GAHBAUER, RA
    STRAHLENTHERAPIE UND ONKOLOGIE, 1989, 165 (2-3): : 75 - 78
  • [35] Evaluation of moderator assemblies for use in an accelerator-based neutron source for boron neutron capture therapy
    Woollard, JE
    Blue, TE
    Gupta, N
    Gahbauer, RA
    NUCLEAR TECHNOLOGY, 1998, 123 (03) : 320 - 334
  • [36] CONCEPTUAL DESIGN OF AN RFQ ACCELERATOR-BASED NEUTRON SOURCE FOR BORON NEUTRON-CAPTURE THERAPY
    WANGLER, TP
    STOVALL, JE
    BHATIA, TS
    WANG, CK
    BLUE, TE
    GAHBAUER, RA
    PROCEEDINGS OF THE 1989 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: ACCELERATOR SCIENCE AND TECHNOLOGY, 1989, : 678 - 680
  • [37] Electrostatic design and beam transport for a folded tandem electrostatic quadrupole accelerator facility for accelerator-based boron neutron capture therapy
    Thatar Vento, V.
    Bergueiro, J.
    Cartelli, D.
    Valda, A. A.
    Kreiner, A. J.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (12) : 1649 - 1653
  • [38] Optimization of target, moderator, and collimator in the accelerator-based boron neutron capture therapy system: A Monte Carlo study
    Cheon, Bo-Wi
    Yoo, Dohyeon
    Park, Hyojun
    Lee, Hyun Cheol
    Shin, Wook-Geun
    Choi, Hyun Joon
    Hong, Bong Hwan
    Chung, Heejun
    Min, Chul Hee
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2021, 53 (06) : 1970 - 1978
  • [39] A feasibility study on a small electron linear accelerator-based beam shaping assembly for boron neutron capture therapy
    Hiraga, F.
    Prateepkaew, J.
    APPLIED RADIATION AND ISOTOPES, 2025, 217
  • [40] Relative biological effectiveness for epithermal neutron beam contaminated with fast neutrons in the linear accelerator-based boron neutron capture therapy system coupled to a solid-state lithium target
    Nakamura, Satoshi
    Imamichi, Shoji
    Shimada, Kenzi
    Takemori, Mihiro
    Kanai, Yui
    Iijima, Kotaro
    Chiba, Takahito
    Nakayama, Hiroki
    Nakaichi, Tetsu
    Mikasa, Shohei
    Urago, Yuka
    Kashihara, Tairo
    Takahashi, Kana
    Nishio, Teiji
    Okamoto, Hiroyuki
    Itami, Jun
    Ishiai, Masamichi
    Suzuki, Minoru
    Igaki, Hiroshi
    Masutani, Mitsuko
    JOURNAL OF RADIATION RESEARCH, 2023, 64 (04) : 661 - 667