Optimizing design of inorganic scintillator optical fiber X-ray sensors

被引:0
|
作者
He, Bo [1 ]
Wang, Jingjing [1 ]
Chen, Ziyin [1 ]
Yang, Haojie [1 ]
Feng, Yong [2 ]
Yang, Bin [3 ]
Shi, Qieming [1 ]
Qian, Jinqian [1 ]
Lewis, Elfed [4 ]
Geng, Tao [1 ]
Sun, Weimin [1 ]
机构
[1] Harbin Engn Univ, Key Lab Infiber Integrated Opt, Minist Educ China, Harbin 150001, Peoples R China
[2] Qingdao Huangdao Dist Peoples Hosp, Qingdao 266400, Peoples R China
[3] Heilongjiang Inst Atom Energy, Harbin, Peoples R China
[4] Univ Limerick, Opt Fiber Sensors Res Ctr, Limerick, Ireland
基金
中国国家自然科学基金;
关键词
Radiotherapy; Radiation dosimetry; Fiber X-ray sensors; Over-response; RADIATION-THERAPY; RADIOTHERAPY; INCIDENT; DETECTOR;
D O I
10.1016/j.yofte.2024.103989
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, two approaches have been adopted to optimize the design of optical fiber X-ray sensors (OFXS). One approach involves using the hemisphere tip structure OFXS, while the other considers increasing the embedding depth of the scintillator in the embedded structure OFXS. The four OFXS designs considered include a 1 mm diameter hemispherical tip structure as well as embedded structure OFXSs with embedding depths of 1 mm, 3 mm, and 5 mm. Experimental results indicate that all four OFXSs exhibit a dose linearity above 0.999938 and dose rate linearity above 0.99991. The optical signal generated by hemisphere tip structure OFXS is 2-3 times higher compared to the embedded structure OFXSs. In the case of the embedded OFXS, increasing the embedding depth cannot effectively improve its sensitivity. And when measuring percentage depth dose (PDD) characteristics, no significant difference was observed for the four OFXSs. In addition, compared to the PDD curve measured using ionization chamber (IC), all OFXS exhibit an over-response phenomenon. These results show that the over-response phenomenon is not related to the structure of OFXS or the volume of scintillator, but only to the scintillator material. Therefore, subsequent calibration of OFXS needs to focus on studying the luminescence characteristics of the scintillator.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Multidisciplinary evaluation of X-ray optical fiber sensors
    Sporea, Dan
    Mihai, Laura
    Tiseanu, Ion
    Vata, Ion
    McCarthy, Denis
    O'Keeffe, Sinead
    Lewis, Elfed
    SENSORS AND ACTUATORS A-PHYSICAL, 2014, 213 : 79 - 88
  • [2] Characterization of Scintillating X-ray Optical Fiber Sensors
    Sporea, Dan
    Mihai, Laura
    Vata, Ion
    McCarthy, Denis
    O'Keeffe, Sinead
    Lewis, Elfed
    SENSORS, 2014, 14 (02): : 3445 - 3457
  • [3] Spectrometer for ultrashort X-ray based on scintillator and optical fiber: proof of principle study
    Song, Honghu
    Qiu, Rui
    Yi, Hongchang
    Zuo, Qi
    Liu, Yining
    Wu, Zhen
    Li, Junli
    JOURNAL OF INSTRUMENTATION, 2023, 18 (02)
  • [4] Optimizing Optical Nanostructures for X-ray Detection
    Segal, Ohad
    Shultzman, Avner
    Kurman, Yaniv
    Kaminer, Ido
    5TH INTERNATIONAL CONFERENCE ON METAMATERIALS AND NANOPHOTONICS (METANANO 2020), 2020, 2300
  • [5] A Review on X-ray Excited Emission Decay Dynamics in Inorganic Scintillator Materials
    Kumar, Vineet
    Luo, Zhiping
    PHOTONICS, 2021, 8 (03) : 1 - 27
  • [6] Effect of photons and electrons on the over-response of optical fiber X-ray sensors
    He, Bo
    Xie, Tianci
    Zhang, Bin
    Qian, Jinqian
    Li, Haopeng
    Shi, Qieming
    Hao, Wenjing
    Qin, Zhuang
    Lewis, Elfed
    Sun, Weimin
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 376
  • [7] An experimental and theoretical study of the influence of Cerenkov radiation on optical fiber X-ray sensors
    Li, Haopeng
    Xie, Tianci
    Qian, Jinqian
    Shi, Qieming
    Zhang, Bin
    He, Bo
    Dai, Xinyu
    Zhao, Wenhui
    Li, Song
    Qin, Zhuang
    Xu, Jun
    Feng, Kun
    Lewis, Elfed
    Sun, Weimin
    MEASUREMENT, 2021, 171 (171)
  • [8] Highly Sensitive Extrinsic X-Ray Polymer Optical Fiber Sensors Based on Fiber Tip Modification
    de Andres, Ana I.
    O'Keeffe, Sinead
    Chen, Lingxia
    Esteban, Oscar
    IEEE SENSORS JOURNAL, 2017, 17 (16) : 5112 - 5117
  • [9] Pixel-Structured Scintillator with Polymeric Microstructures for X-Ray Image Sensors
    Jung, Im Deok
    Cho, Min Kook
    Bae, Kong Myeong
    Lee, Sang Min
    Jung, Phill Gu
    Kim, Ho Kyung
    Kim, Sung Sik
    Ko, Jong Soo
    ETRI JOURNAL, 2008, 30 (05) : 747 - 749
  • [10] Effect of different scintillator choices on the X-ray imaging performance of CMOS sensors
    Alikunju, Rimcy Palakkappilly
    Kearney, Stephen
    Moss, Robert
    Khan, Asmar
    Stamatis, Yiannis
    Bullard, Edward
    Anaxagoras, Thalis
    Brodrick, James
    Olivo, Alessandro
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1050