Optimizing design of inorganic scintillator optical fiber X-ray sensors

被引:0
|
作者
He, Bo [1 ]
Wang, Jingjing [1 ]
Chen, Ziyin [1 ]
Yang, Haojie [1 ]
Feng, Yong [2 ]
Yang, Bin [3 ]
Shi, Qieming [1 ]
Qian, Jinqian [1 ]
Lewis, Elfed [4 ]
Geng, Tao [1 ]
Sun, Weimin [1 ]
机构
[1] Harbin Engn Univ, Key Lab Infiber Integrated Opt, Minist Educ China, Harbin 150001, Peoples R China
[2] Qingdao Huangdao Dist Peoples Hosp, Qingdao 266400, Peoples R China
[3] Heilongjiang Inst Atom Energy, Harbin, Peoples R China
[4] Univ Limerick, Opt Fiber Sensors Res Ctr, Limerick, Ireland
基金
中国国家自然科学基金;
关键词
Radiotherapy; Radiation dosimetry; Fiber X-ray sensors; Over-response; RADIATION-THERAPY; RADIOTHERAPY; INCIDENT; DETECTOR;
D O I
10.1016/j.yofte.2024.103989
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, two approaches have been adopted to optimize the design of optical fiber X-ray sensors (OFXS). One approach involves using the hemisphere tip structure OFXS, while the other considers increasing the embedding depth of the scintillator in the embedded structure OFXS. The four OFXS designs considered include a 1 mm diameter hemispherical tip structure as well as embedded structure OFXSs with embedding depths of 1 mm, 3 mm, and 5 mm. Experimental results indicate that all four OFXSs exhibit a dose linearity above 0.999938 and dose rate linearity above 0.99991. The optical signal generated by hemisphere tip structure OFXS is 2-3 times higher compared to the embedded structure OFXSs. In the case of the embedded OFXS, increasing the embedding depth cannot effectively improve its sensitivity. And when measuring percentage depth dose (PDD) characteristics, no significant difference was observed for the four OFXSs. In addition, compared to the PDD curve measured using ionization chamber (IC), all OFXS exhibit an over-response phenomenon. These results show that the over-response phenomenon is not related to the structure of OFXS or the volume of scintillator, but only to the scintillator material. Therefore, subsequent calibration of OFXS needs to focus on studying the luminescence characteristics of the scintillator.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Optical design of X-ray focusing telescope
    Qiang Peng-Fei
    Sheng Li-Zhi
    Li Lin-Sen
    Yan Yong-Qing
    Liu Zhe
    Zhou Xiao-Hong
    ACTA PHYSICA SINICA, 2019, 68 (16)
  • [22] Optical Design of the X-ray Telescope for XEUS
    Willingale, R.
    Kunieda, H.
    Okajima, T.
    Naitoh, M.
    OPTICS FOR EUV, X-RAY, AND GAMMA-RAY ASTRONOMY II, 2005, 5900
  • [23] Optical design for a survey x-ray telescope
    Saha, Timo T.
    Zhang, William W.
    McClelland, Ryan S.
    SPACE TELESCOPES AND INSTRUMENTATION 2014: ULTRAVIOLET TO GAMMA RAY, 2014, 9144
  • [24] Organic-inorganic hybrid perovskite scintillator for high-resolution X-ray imaging
    Yan, Weipeng
    Duan, Baojun
    Zhu, Zijian
    Song, Yan
    Song, Guzhou
    Ma, Jiming
    Li, Binkang
    Liu, Yucheng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2024, 546
  • [25] Ultrafast inorganic scintillator-based front imager for Gigahertz Hard X-ray imaging
    Hu, Chen
    Zhang, Liyuan
    Zhu, Ren-Yuan
    Demarteau, Marcel
    Wagner, Robert
    Xia, Lei
    Xie, Junqi
    Li, Xuan
    Wang, Zhehui
    Shih, Yanhua
    Smith, Thomas
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 940 : 223 - 229
  • [26] Scintillator to CCD coupling in X-ray microtomography
    Davis, Graham R.
    Elliott, James C.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [27] Lanthanum chloride scintillator for X-ray detection
    Martin, T.
    Allier, C.
    Bernard, F.
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1156 - 1159
  • [28] A new x-ray scintillator for digital radiography
    Nagarkar, VV
    Tipnis, SV
    Miller, SR
    Lempicki, A
    Brecher, C
    Szupryczynski, P
    Lingertat, H
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 134 - 137
  • [29] Optical imaging in tissue with X-ray excited luminescent sensors
    Chen, Hongyu
    Longfield, David E.
    Varahagiri, Venkata S.
    Nguyen, KhanhVan T.
    Patrick, Amanda L.
    Qian, Haijun
    VanDerveer, Donald G.
    Anker, Jeffrey N.
    ANALYST, 2011, 136 (17) : 3438 - 3445
  • [30] Fabrication of fiber-optic radiation sensor tips with inorganic scintillator for remote sensing of X or γ-ray
    Lee, BS
    Hwang, YM
    Cho, HS
    Kim, S
    Cho, S
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 865 - 868