Optimizing design of inorganic scintillator optical fiber X-ray sensors

被引:0
|
作者
He, Bo [1 ]
Wang, Jingjing [1 ]
Chen, Ziyin [1 ]
Yang, Haojie [1 ]
Feng, Yong [2 ]
Yang, Bin [3 ]
Shi, Qieming [1 ]
Qian, Jinqian [1 ]
Lewis, Elfed [4 ]
Geng, Tao [1 ]
Sun, Weimin [1 ]
机构
[1] Harbin Engn Univ, Key Lab Infiber Integrated Opt, Minist Educ China, Harbin 150001, Peoples R China
[2] Qingdao Huangdao Dist Peoples Hosp, Qingdao 266400, Peoples R China
[3] Heilongjiang Inst Atom Energy, Harbin, Peoples R China
[4] Univ Limerick, Opt Fiber Sensors Res Ctr, Limerick, Ireland
基金
中国国家自然科学基金;
关键词
Radiotherapy; Radiation dosimetry; Fiber X-ray sensors; Over-response; RADIATION-THERAPY; RADIOTHERAPY; INCIDENT; DETECTOR;
D O I
10.1016/j.yofte.2024.103989
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, two approaches have been adopted to optimize the design of optical fiber X-ray sensors (OFXS). One approach involves using the hemisphere tip structure OFXS, while the other considers increasing the embedding depth of the scintillator in the embedded structure OFXS. The four OFXS designs considered include a 1 mm diameter hemispherical tip structure as well as embedded structure OFXSs with embedding depths of 1 mm, 3 mm, and 5 mm. Experimental results indicate that all four OFXSs exhibit a dose linearity above 0.999938 and dose rate linearity above 0.99991. The optical signal generated by hemisphere tip structure OFXS is 2-3 times higher compared to the embedded structure OFXSs. In the case of the embedded OFXS, increasing the embedding depth cannot effectively improve its sensitivity. And when measuring percentage depth dose (PDD) characteristics, no significant difference was observed for the four OFXSs. In addition, compared to the PDD curve measured using ionization chamber (IC), all OFXS exhibit an over-response phenomenon. These results show that the over-response phenomenon is not related to the structure of OFXS or the volume of scintillator, but only to the scintillator material. Therefore, subsequent calibration of OFXS needs to focus on studying the luminescence characteristics of the scintillator.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Liquid filled microstructured optical fiber for x-ray detection
    DeHaven, S. L.
    Albin, S.
    Kelliher, W. C.
    OPTICS EXPRESS, 2010, 18 (13): : 13754 - 13760
  • [42] Theory and optical design of x-ray echo spectrometers
    Shvyd'ko, Yuri
    PHYSICAL REVIEW A, 2017, 96 (02)
  • [43] THE BEPC FOCUSING X-RAY BEAMLINE OPTICAL DESIGN
    SHU, D
    LIU, W
    WANG, W
    CONG, Z
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 134 - 139
  • [44] Design & development of Hard X-ray imaging detector using Scintillator and Si Photomultiplier
    Goyal, S. K.
    Naik, Amisha P.
    Mithun, N. P. S.
    Vadawale, S. V.
    Acharya, Y. B.
    Patel, A. R.
    Ladiya, T.
    Devashrayee, Niranjan M.
    HIGH ENERGY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY VII, 2016, 9915
  • [45] Optical and x-ray characterization of two novel CMOS image sensors
    Bohndiek, Sarah E.
    Arvanitis, Costas D.
    Venanzi, Cristian
    Royle, Gary J.
    Clark, Andy T.
    Crooks, Jamie P.
    Prydderch, Mark L.
    Turchetta, Renato
    Blue, Andrew
    Speller, Robert D.
    ULTRAFAST PHENOMENA IN SEMICONDUCTORS AND NANOSTRUCTURE MATERIALS XI AND SEMICONDUCTOR PHOTODETECTORS IV, 2007, 6471
  • [46] Optimizing the design of gas microstrip detectors for soft X-ray detection
    Bateman, JE
    Barlow, R
    Derbyshire, GE
    Mir, JA
    Stephenson, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 894 - 898
  • [47] Halide Perovskite, a Potential Scintillator for X-Ray Detection
    Zhou, Faguang
    Li, Zhizai
    Lan, Wei
    Wang, Qian
    Ding, Liming
    Jin, Zhiwen
    SMALL METHODS, 2020, 4 (10)
  • [48] Stretchable scintillator composites for indirect X-ray detectors
    Oliveira, J.
    Correia, V.
    Costa, P.
    Francesko, A.
    Rocha, G.
    Lanceros-Mendez, S.
    COMPOSITES PART B-ENGINEERING, 2018, 133 : 226 - 231
  • [49] Modeling of the performance of scintillator based X-ray detectors
    Rocha, JG
    Correia, JH
    Lanceros-Mendez, S
    PROCEEDINGS OF THE IEEE SENSORS 2004, VOLS 1-3, 2004, : 1257 - 1260
  • [50] Scintillator materials for x-ray detectors and beam monitors
    Martin, T.
    Koch, A.
    Nikl, M.
    MRS BULLETIN, 2017, 42 (06) : 451 - 456