An experimental and theoretical study of the influence of Cerenkov radiation on optical fiber X-ray sensors

被引:1
|
作者
Li, Haopeng [1 ]
Xie, Tianci [1 ]
Qian, Jinqian [1 ]
Shi, Qieming [1 ]
Zhang, Bin [1 ]
He, Bo [1 ]
Dai, Xinyu [1 ]
Zhao, Wenhui [1 ]
Li, Song [1 ]
Qin, Zhuang [2 ]
Xu, Jun [3 ]
Feng, Kun [4 ]
Lewis, Elfed [5 ]
Sun, Weimin [1 ]
机构
[1] Harbin Engn Univ, Key Lab In Fiber Integrated Opt, Minist Educ China, Harbin 150001, Peoples R China
[2] Heilongjiang Univ, Heilongjiang Prov Key Lab Metamat Phys & Device, Harbin 150080, Peoples R China
[3] Harbin Med Univ, Comprehens Canc Ctr, Affiliated Hosp 2, Harbin 150001, Peoples R China
[4] Shanghai Ninth Peoples Hosp, Dept Oral & Maxillofacial Head Neck Oncol, Shanghai 200011, Peoples R China
[5] Univ Limerick, Opt Fiber Sensors Res Ctr, Limerick, Ireland
基金
中国国家自然科学基金;
关键词
Optical fiber sensors; X-ray detection; Cerenkov radiation; Recoil electrons; Percentage depth dose (PDD);
D O I
10.1016/j.measurement.2020.108863
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The use of optical fiber X-ray sensors is of great significance in X-ray detection. To reduce the influence of background noise attributed to sources such as Cerenkov radiation, the response of a plain (no scintillator material added) optical fiber to the X-ray radiation is investigated. The percentage dose-depth (PDD) of plain optical fibers with and without visible light blocking end caps are calculated and are clearly different. The leakage of Cerenkov radiation and presence of Compton scattering from water into the sensing probe is considered as the reason for the difference. A theoretical model to explain the difference is proposed. The experimental results fit well to the theoretical expectation.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Theoretical analysis and experimental research of the optical fiber imperfections' X-ray inspection
    Cui J.
    Cui Q.
    Xu Z.
    Bai X.
    Zhongguo Jiguang/Chinese Journal of Lasers, 2010, 37 (SUPPL. 1): : 98 - 104
  • [2] Multidisciplinary evaluation of X-ray optical fiber sensors
    Sporea, Dan
    Mihai, Laura
    Tiseanu, Ion
    Vata, Ion
    McCarthy, Denis
    O'Keeffe, Sinead
    Lewis, Elfed
    SENSORS AND ACTUATORS A-PHYSICAL, 2014, 213 : 79 - 88
  • [3] Characterization of Scintillating X-ray Optical Fiber Sensors
    Sporea, Dan
    Mihai, Laura
    Vata, Ion
    McCarthy, Denis
    O'Keeffe, Sinead
    Lewis, Elfed
    SENSORS, 2014, 14 (02): : 3445 - 3457
  • [4] CERENKOV RADIATION AS AN INTENSE X-RAY SOURCE
    BAZYLEV, VA
    GLEBOV, VI
    DENISOV, EI
    ZHEVAGO, NK
    KHLEBNIKOV, AS
    JETP LETTERS, 1976, 24 (07) : 371 - 374
  • [5] Study of X-ray radiation damage in silicon sensors
    Zhang, J.
    Fretwurst, E.
    Klanner, R.
    Perrey, H.
    Pintilie, I.
    Poehlsen, T.
    Schwandt, J.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [6] Theoretical and experimental study on the optical fiber bundle displacement sensors
    Cao, Huimin
    Chen, Youping
    Zhou, Zude
    Zhang, Gang
    SENSORS AND ACTUATORS A-PHYSICAL, 2007, 136 (02) : 580 - 587
  • [7] Optimizing design of inorganic scintillator optical fiber X-ray sensors
    He, Bo
    Wang, Jingjing
    Chen, Ziyin
    Yang, Haojie
    Feng, Yong
    Yang, Bin
    Shi, Qieming
    Qian, Jinqian
    Lewis, Elfed
    Geng, Tao
    Sun, Weimin
    OPTICAL FIBER TECHNOLOGY, 2024, 88
  • [8] X-RAY CERENKOV RADIATION AT GRAZING-INCIDENCE OF ELECTRONS
    ZHEVAGO, MK
    GLEBOV, VI
    PHYSICS LETTERS A, 1991, 160 (06) : 564 - 570
  • [9] X-ray Fluorescence Study with Pixellated CZT Radiation Sensors
    Meier, Dirk
    Chen, Si
    Wagenaar, Douglas J.
    Maehlum, Gunnar E.
    Patt, Bradley E.
    Sundal, Bjorn M.
    Wang, Yuchuan
    Tsui, Benjamin M. W.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 305 - 309
  • [10] Megavoltage X-Ray Imaging Based on Cerenkov Effect: A New Application of Optical Fibres to Radiation Therapy
    Teymurazyan, A.
    Pang, G.
    INTERNATIONAL JOURNAL OF OPTICS, 2012, 2012