Evaluation and optimization of annual light variations for visual and non-visual effects within a ground-floor middle school classroom

被引:1
|
作者
Hao, Huiyu [1 ]
Xu, Junli [1 ]
Schlangen, Luc J. M. [2 ,3 ]
机构
[1] Soochow Univ, Sch Architecture, Suzhou, Peoples R China
[2] Eindhoven Univ Technol, Dept Ind Engn & Innovat Sci, Human Technol Interact Grp, Eindhoven, Netherlands
[3] Eindhoven Univ Technol, Intelligent Lighting Inst, Eindhoven, Netherlands
来源
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Daylighting performance; Electric lighting; Non-visual effects; Visual effects; Dynamic metrics; DAYLIGHT PERFORMANCE; ENERGY; QUALITY; DESIGN; SENSITIVITY; SIMULATION; BUILDINGS; CHILDREN; COMFORT; METRICS;
D O I
10.1016/j.jobe.2024.111293
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The quality of the luminous environment in classrooms significantly impacts the performance, physical and psychological health of teenagers. This study proposes an emerging framework and improves the metrics to concurrently evaluate the visual and non-visual effects of annual lighting performance within Chinese classrooms. The year-round spatial and temporal variations of horizontal (desk) illuminance and vertical (eye-level) melanopic Equivalent Daylight Illuminance (mel-EDI) in ground-floor classrooms in Suzhou were evaluated using the latest Lark v2 lighting simulation tool. The Chinese Standard and WELL Building Standard were used to evaluate the compliance degree of static and dynamic metrics in the classroom under two conditions: daylightonly (all blinds open) and actual use (with blinds and electric lighting). In daylight-only conditions, the middle and south areas did not meet the visual requirements (>= 450 lx desk illuminance for >= 4 h) and the middle, south and front areas provided insufficient non-visual/circadian stimulation (>= 250 lx mel-EDI at eye-level for >= 4 h). In actual use conditions the insufficiencies were even more severe due to the use of low-transmittance blinds and glazing and inappropriate electric lighting configurations. Based on an evaluation of 27 (day)lighting scenarios, glazing transmittance of 0.78 and blinds transmittance of 0.5 were recommended. Additionally, electric lighting configurations were recommended to choose direct luminaires with luminous flux below 4000 lm or bidirectional luminaires of 3500-5000 lm to meet the visual and non-visual requirements of users, while also securing visual comfort and energy conservation within a reasonable range. The results of the study can be applied to secure adequate visual and non-visual stimulation within typical classrooms in Suzhou and other cities of East China that share similar climatic characteristics and educational building types.
引用
收藏
页数:19
相关论文
共 44 条
  • [41] In Vivo Quantification of the Retinal Reflectance Spectral Composition in Elderly Subjects before and after Cataract Surgery: Implications for the Non-Visual Effects of Light
    Gimenez, Marina C.
    Kanis, Martijn J.
    Beersma, Domien G. M.
    van der Pol, Bert A. E.
    van Norren, Dirk
    Gordijn, Marijke C. M.
    JOURNAL OF BIOLOGICAL RHYTHMS, 2010, 25 (02) : 123 - 131
  • [42] Review on age-related differences in non-visual effects of light: melatonin suppression, circadian phase shift and pupillary light reflex in children to older adults
    Eto, Taisuke
    Higuchi, Shigekazu
    JOURNAL OF PHYSIOLOGICAL ANTHROPOLOGY, 2023, 42 (01)
  • [43] Review on age-related differences in non-visual effects of light: melatonin suppression, circadian phase shift and pupillary light reflex in children to older adults
    Taisuke Eto
    Shigekazu Higuchi
    Journal of Physiological Anthropology, 42
  • [44] Phosphor-free, color-mixed, and efficient illuminant: Multi-chip packaged LEDs for optimizing blue light hazard and non-visual biological effects
    Zhu, Xin
    Guo, Xing
    Zhang, Jianli
    Liu, Junlin
    Jiang, Fengyi
    OPTICS AND LASERS IN ENGINEERING, 2020, 134 (134)