Evaluation and optimization of annual light variations for visual and non-visual effects within a ground-floor middle school classroom

被引:1
|
作者
Hao, Huiyu [1 ]
Xu, Junli [1 ]
Schlangen, Luc J. M. [2 ,3 ]
机构
[1] Soochow Univ, Sch Architecture, Suzhou, Peoples R China
[2] Eindhoven Univ Technol, Dept Ind Engn & Innovat Sci, Human Technol Interact Grp, Eindhoven, Netherlands
[3] Eindhoven Univ Technol, Intelligent Lighting Inst, Eindhoven, Netherlands
来源
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Daylighting performance; Electric lighting; Non-visual effects; Visual effects; Dynamic metrics; DAYLIGHT PERFORMANCE; ENERGY; QUALITY; DESIGN; SENSITIVITY; SIMULATION; BUILDINGS; CHILDREN; COMFORT; METRICS;
D O I
10.1016/j.jobe.2024.111293
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The quality of the luminous environment in classrooms significantly impacts the performance, physical and psychological health of teenagers. This study proposes an emerging framework and improves the metrics to concurrently evaluate the visual and non-visual effects of annual lighting performance within Chinese classrooms. The year-round spatial and temporal variations of horizontal (desk) illuminance and vertical (eye-level) melanopic Equivalent Daylight Illuminance (mel-EDI) in ground-floor classrooms in Suzhou were evaluated using the latest Lark v2 lighting simulation tool. The Chinese Standard and WELL Building Standard were used to evaluate the compliance degree of static and dynamic metrics in the classroom under two conditions: daylightonly (all blinds open) and actual use (with blinds and electric lighting). In daylight-only conditions, the middle and south areas did not meet the visual requirements (>= 450 lx desk illuminance for >= 4 h) and the middle, south and front areas provided insufficient non-visual/circadian stimulation (>= 250 lx mel-EDI at eye-level for >= 4 h). In actual use conditions the insufficiencies were even more severe due to the use of low-transmittance blinds and glazing and inappropriate electric lighting configurations. Based on an evaluation of 27 (day)lighting scenarios, glazing transmittance of 0.78 and blinds transmittance of 0.5 were recommended. Additionally, electric lighting configurations were recommended to choose direct luminaires with luminous flux below 4000 lm or bidirectional luminaires of 3500-5000 lm to meet the visual and non-visual requirements of users, while also securing visual comfort and energy conservation within a reasonable range. The results of the study can be applied to secure adequate visual and non-visual stimulation within typical classrooms in Suzhou and other cities of East China that share similar climatic characteristics and educational building types.
引用
收藏
页数:19
相关论文
共 44 条
  • [21] Lighting in indoor environments: Visual and non-visual effects of light sources with different spectral power distributions
    Bellia, L.
    Bisegna, F.
    Spada, G.
    BUILDING AND ENVIRONMENT, 2011, 46 (10) : 1984 - 1992
  • [22] APPLICATION STUDIES ON NON-VISUAL EFFECTS OF LIGHT WITH TRADITIONAL AND SOLID STATE LIGHT SOURCES
    Wojtysiak, A.
    Lang, D.
    PROCEEDINGS OF THE CIE CENTENARY CONFERENCE TOWARDS A NEW CENTURY OF LIGHT, 2013, : 91 - 94
  • [24] Does Blue Light Wake You Up or Make You Down? Visual and Non-Visual Effects of Varying Light Spectra
    Hurlbert, Anya
    Gupta, Gaurav
    Lai, Yvonne
    Gross, Naomi
    Aston, Stacey
    Pearce, Brad
    Anderson, Kirstie
    PERCEPTION, 2019, 48 : 6 - 6
  • [25] Assessment of light performance in work environments, based on the non-visual effects of natural light on health
    Giraldo Gaviria, Veronica
    Arango Diaz, Lucas
    Herreno Tellez, Elisabeth
    ACE-ARCHITECTURE CITY AND ENVIRONMENT, 2020, 15 (43): : 1 - 14
  • [26] Non-visual effects of light: How to use light to promote circadian entrainment and elicit alertness
    Figueiro, M. G.
    Nagare, R.
    Price, L. L. A.
    LIGHTING RESEARCH & TECHNOLOGY, 2018, 50 (01) : 38 - 62
  • [27] Non-visual effects of flat panel display with light emitting diode backlight on human
    Song, Li-Yan
    Li, Jun-Kai
    Mou, Tong-Sheng
    Guangzi Xuebao/Acta Photonica Sinica, 2013, 42 (07): : 768 - 771
  • [28] Fabrication of Circadian Light Meter with Non-Periodic Optical Filters to Evaluate the Non-Visual Effects of Light on Humans
    Eo, Yun Jae
    Kim, Seohyeon
    Lee, Keyong Nam
    Kim, Dae Hwan
    Kim, Changwook
    Lee, Seung Min
    Do, Young Rag
    APPLIED SCIENCES-BASEL, 2021, 11 (18):
  • [30] Integrated lighting ergonomics: A review on the association between non-visual effects of light and ergonomics in the enclosed cabins
    Gou, Zhiming
    Gou, Bingchen
    Liao, Wenyi
    Bao, Yuxue
    Deng, Yongqi
    BUILDING AND ENVIRONMENT, 2023, 243