Evaluation and optimization of annual light variations for visual and non-visual effects within a ground-floor middle school classroom

被引:1
|
作者
Hao, Huiyu [1 ]
Xu, Junli [1 ]
Schlangen, Luc J. M. [2 ,3 ]
机构
[1] Soochow Univ, Sch Architecture, Suzhou, Peoples R China
[2] Eindhoven Univ Technol, Dept Ind Engn & Innovat Sci, Human Technol Interact Grp, Eindhoven, Netherlands
[3] Eindhoven Univ Technol, Intelligent Lighting Inst, Eindhoven, Netherlands
来源
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Daylighting performance; Electric lighting; Non-visual effects; Visual effects; Dynamic metrics; DAYLIGHT PERFORMANCE; ENERGY; QUALITY; DESIGN; SENSITIVITY; SIMULATION; BUILDINGS; CHILDREN; COMFORT; METRICS;
D O I
10.1016/j.jobe.2024.111293
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The quality of the luminous environment in classrooms significantly impacts the performance, physical and psychological health of teenagers. This study proposes an emerging framework and improves the metrics to concurrently evaluate the visual and non-visual effects of annual lighting performance within Chinese classrooms. The year-round spatial and temporal variations of horizontal (desk) illuminance and vertical (eye-level) melanopic Equivalent Daylight Illuminance (mel-EDI) in ground-floor classrooms in Suzhou were evaluated using the latest Lark v2 lighting simulation tool. The Chinese Standard and WELL Building Standard were used to evaluate the compliance degree of static and dynamic metrics in the classroom under two conditions: daylightonly (all blinds open) and actual use (with blinds and electric lighting). In daylight-only conditions, the middle and south areas did not meet the visual requirements (>= 450 lx desk illuminance for >= 4 h) and the middle, south and front areas provided insufficient non-visual/circadian stimulation (>= 250 lx mel-EDI at eye-level for >= 4 h). In actual use conditions the insufficiencies were even more severe due to the use of low-transmittance blinds and glazing and inappropriate electric lighting configurations. Based on an evaluation of 27 (day)lighting scenarios, glazing transmittance of 0.78 and blinds transmittance of 0.5 were recommended. Additionally, electric lighting configurations were recommended to choose direct luminaires with luminous flux below 4000 lm or bidirectional luminaires of 3500-5000 lm to meet the visual and non-visual requirements of users, while also securing visual comfort and energy conservation within a reasonable range. The results of the study can be applied to secure adequate visual and non-visual stimulation within typical classrooms in Suzhou and other cities of East China that share similar climatic characteristics and educational building types.
引用
收藏
页数:19
相关论文
共 44 条
  • [31] ENLIGHT: A consensus checklist for reporting laboratory-based studies on the non-visual effects of light in humans
    Spitschan, Manuel
    Kervezee, Laura
    Lok, Renske
    McGlashan, Elise
    Najjar, Raymond P.
    EBIOMEDICINE, 2023, 98
  • [32] Evaluation of visual and non-visual effects of daylighting in healthcare patient rooms using climate-based daylight metrics and melanopic metrics
    Englezou, Maria
    Michael, Aimilios
    BUILDSIM NORDIC 2022, 2022, 362
  • [33] A theoretical model for evaluation of non-visual effects of lighting based on human performance: Comprehensive research ideas
    Zhang, Xian
    Ma, Lin
    Chen, Jing
    Fu, Jinchi
    Wang, Jingluan
    Wang, Yao
    Zhu, Mengya
    Yu, Mingjiu
    Chen, Dengkai
    DISPLAYS, 2025, 88
  • [34] An application of measuring visual and non-visual sensorial experiences of nature for children within primary school spaces Child-nature-distance case studies in Glasgow, Scotland
    Phuong Thanh To
    Grierson, David
    ARCHNET-IJAR INTERNATIONAL JOURNAL OF ARCHITECTURAL RESEARCH, 2020, 14 (02) : 167 - 186
  • [35] Non-Visual Effects of Light on Melatonin, Alertness and Cognitive Performance: Can Blue-Enriched Light Keep Us Alert?
    Chellappa, Sarah Laxhmi
    Steiner, Roland
    Blattner, Peter
    Oelhafen, Peter
    Goetz, Thomas
    Cajochen, Christian
    PLOS ONE, 2011, 6 (01):
  • [36] VISUAL AND NON-VISUAL EFFECTS OF DIFFERENT SPECTRAL POWER DISTRIBUTIONS FROM LIGHT SOURCES - LIGHT EMITTING DIODES (LED) VS. 3-PHOSPHORUS FLUORESCENT TUBES
    Goven, T.
    Laike, T.
    PROCEEDINGS OF THE CIE CENTENARY CONFERENCE TOWARDS A NEW CENTURY OF LIGHT, 2013, : 95 - 100
  • [37] Good Places to Live and Sleep Well: A Literature Review about the Role of Architecture in Determining Non-Visual Effects of Light
    Bellia, Laura
    Fragliasso, Francesca
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (03) : 1 - 29
  • [38] Non-visual Opsins and Novel Photo-Detectors in the Vertebrate Inner Retina Mediate Light Responses Within the Blue Spectrum Region
    Guido, Mario E.
    Marchese, Natalia A.
    Rios, Maximiliano N.
    Morera, Luis P.
    Diaz, Nicolas M.
    Garbarino-Pico, Eduardo
    Contin, Maria Ana
    CELLULAR AND MOLECULAR NEUROBIOLOGY, 2022, 42 (01) : 59 - 83
  • [39] Non-visual Opsins and Novel Photo-Detectors in the Vertebrate Inner Retina Mediate Light Responses Within the Blue Spectrum Region
    Mario E. Guido
    Natalia A. Marchese
    Maximiliano N. Rios
    Luis P. Morera
    Nicolás M. Diaz
    Eduardo Garbarino-Pico
    María Ana Contin
    Cellular and Molecular Neurobiology, 2022, 42 : 59 - 83
  • [40] Age-dependent non-visual effects of a moderately bright light exposure during 40-h of extended wakefulness
    Gabel, V.
    Maire, M.
    Reichert, C. F.
    Schmidt, C.
    Garbazza, C.
    Cajochen, C.
    Viola, A. U.
    JOURNAL OF SLEEP RESEARCH, 2014, 23 : 174 - 175