Evaluation and optimization of annual light variations for visual and non-visual effects within a ground-floor middle school classroom

被引:1
|
作者
Hao, Huiyu [1 ]
Xu, Junli [1 ]
Schlangen, Luc J. M. [2 ,3 ]
机构
[1] Soochow Univ, Sch Architecture, Suzhou, Peoples R China
[2] Eindhoven Univ Technol, Dept Ind Engn & Innovat Sci, Human Technol Interact Grp, Eindhoven, Netherlands
[3] Eindhoven Univ Technol, Intelligent Lighting Inst, Eindhoven, Netherlands
来源
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Daylighting performance; Electric lighting; Non-visual effects; Visual effects; Dynamic metrics; DAYLIGHT PERFORMANCE; ENERGY; QUALITY; DESIGN; SENSITIVITY; SIMULATION; BUILDINGS; CHILDREN; COMFORT; METRICS;
D O I
10.1016/j.jobe.2024.111293
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The quality of the luminous environment in classrooms significantly impacts the performance, physical and psychological health of teenagers. This study proposes an emerging framework and improves the metrics to concurrently evaluate the visual and non-visual effects of annual lighting performance within Chinese classrooms. The year-round spatial and temporal variations of horizontal (desk) illuminance and vertical (eye-level) melanopic Equivalent Daylight Illuminance (mel-EDI) in ground-floor classrooms in Suzhou were evaluated using the latest Lark v2 lighting simulation tool. The Chinese Standard and WELL Building Standard were used to evaluate the compliance degree of static and dynamic metrics in the classroom under two conditions: daylightonly (all blinds open) and actual use (with blinds and electric lighting). In daylight-only conditions, the middle and south areas did not meet the visual requirements (>= 450 lx desk illuminance for >= 4 h) and the middle, south and front areas provided insufficient non-visual/circadian stimulation (>= 250 lx mel-EDI at eye-level for >= 4 h). In actual use conditions the insufficiencies were even more severe due to the use of low-transmittance blinds and glazing and inappropriate electric lighting configurations. Based on an evaluation of 27 (day)lighting scenarios, glazing transmittance of 0.78 and blinds transmittance of 0.5 were recommended. Additionally, electric lighting configurations were recommended to choose direct luminaires with luminous flux below 4000 lm or bidirectional luminaires of 3500-5000 lm to meet the visual and non-visual requirements of users, while also securing visual comfort and energy conservation within a reasonable range. The results of the study can be applied to secure adequate visual and non-visual stimulation within typical classrooms in Suzhou and other cities of East China that share similar climatic characteristics and educational building types.
引用
收藏
页数:19
相关论文
共 44 条
  • [1] Evaluation on the Non-visual Biological Effects of Light Sources
    Liu Jie
    Zhang Shanduan
    2013 10TH CHINA INTERNATIONAL FORUM ON SOLID STATE LIGHTING (CHINASSL), 2013, : 61 - 64
  • [2] Metrics of non-visual effects of light
    Nazarenko, L.
    Felonenko, D.
    Liashenko, O.
    UKRAINIAN METROLOGICAL JOURNAL, 2024, (04): : 36 - 42
  • [3] The visual and non-visual effects of annual daylighting performance on middle school students: A longitudinal field survey of classrooms in Eastern China
    Xu, Junli
    Gao, Yuqing
    Wu, Yujie
    ENERGY AND BUILDINGS, 2025, 331
  • [4] Physiological Study of Visual and Non-Visual Effects of Light Exposure
    Morioka, Haruki
    Ozawa, Haruki
    Kato, Takeo
    APPLIED SCIENCES-BASEL, 2023, 13 (09):
  • [5] Non-visual effects of light: Implications for design
    Figueiro, Mariana G.
    INTERNATIONAL OPTICAL DESIGN CONFERENCE 2010, 2010, 7652
  • [6] NON-VISUAL EFFECTS OF LIGHT AND COLOUR.
    Kuller, Rikard
    Document - Swedish Council for Building Research, 1981, (D 15):
  • [7] TUNING LIGHT TO SEE AND FEEL BETTER: THE HUMAN VISUAL AND NON-VISUAL RESPONSES TO SPECTRAL VARIATIONS IN LIGHT
    Hurlbert, A.
    Aston, S.
    Pearce, B. M.
    PROCEEDINGS OF CIE 2016 LIGHTING QUALITY AND ENERGY EFFICIENCY, 2016, : 1 - 6
  • [8] A Wearable Illuminance Recorder for Measuring Visual and Non-Visual Effects of Light Simultaneously
    Yang, Fan
    Fang, Wenqing
    Yang, Chaopu
    Lai, Zhenquan
    Zhang, Xu
    2017 14TH CHINA INTERNATIONAL FORUM ON SOLID STATE LIGHTING (SSLCHINA) : INTERNATIONAL FORUM ON WIDE BANDGAP SEMICONDUCTORS (IFWS), 2017, : 125 - 127
  • [9] Proposal for the standard evaluation procedure for non-visual action of light
    Kozakov R.
    Schoepp H.
    Journal of Light and Visual Environment, 2011, 35 (03): : 274 - 277
  • [10] Non-visual effects of indoor light environment on humans: A review
    Xiao, Hui
    Cai, Huiling
    Li, Xuefeng
    PHYSIOLOGY & BEHAVIOR, 2021, 228