Validity and Reliability of Wearable Sensors for Continuous Postoperative Vital Signs Monitoring in Patients Recovering from Trauma Surgery

被引:2
|
作者
van Melzen, Rianne [1 ]
Haveman, Marjolein E. [2 ]
Schuurmann, Richte C. L. [1 ]
van Amsterdam, Kai [2 ]
El Moumni, Mostafa [3 ]
Tabak, Monique [4 ]
Struys, Michel M. R. F. [2 ]
de Vries, Jean-Paul P. M. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Surg, Div Vasc Surg, NL-9713 GZ Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Anesthesiol, NL-9713 GZ Groningen, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Div Trauma Surg, Dept Surg, NL-9713 GZ Groningen, Netherlands
[4] Univ Twente, Dept Biomed Signals & Syst, NL-7500 AE Enschede, Netherlands
关键词
telemonitoring; validity; accuracy; vital signs; wearable sensor; surgical ward; CORRELATION-COEFFICIENTS; STAFF;
D O I
10.3390/s24196379
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
(1) Background: Wearable sensors support healthcare professionals in clinical decision-making by measuring vital parameters such as heart rate (HR), respiration rate (RR), and blood oxygenation saturation (SpO2). This study assessed the validity and reliability of two types of wearable sensors, based on electrocardiogram or photoplethysmography, compared with continuous monitoring of patients recovering from trauma surgery at the postanesthesia care unit. (2) Methods: In a prospective observational study, HR, RR, SpO2, and temperature of patients were simultaneously recorded with the VitalPatch and Radius PPG and compared with reference monitoring. Outcome measures were formulated as correlation coefficient for validity and mean difference with 95% limits of agreement for reliability for four random data pairs and 30-min pairs per vital sign per patient. (3) Results: Included were 60 patients. Correlation coefficients for VitalPatch were 0.57 to 0.85 for HR and 0.08 to 0.16 for RR, and for Radius PPG, correlation coefficients were 0.60 to 0.83 for HR, 0.20 to 0.12 for RR, and 0.57 to 0.61 for SpO2. Both sensors presented mean differences within the cutoff values of acceptable difference. (4) Conclusions: Moderate to strong correlations for HR and SpO2 were demonstrated. Although mean differences were within acceptable cutoff values for all vital signs, only limits of agreement for HR measured by electrocardiography were considered clinically acceptable.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Patient attitudes towards remote continuous vital signs monitoring on general surgery wards: An interview study
    Downey, C. L.
    Brown, J. M.
    Jayne, D. G.
    Randell, R.
    INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 2018, 114 : 52 - 56
  • [42] Continuous monitoring of vital sign abnormalities; association to clinical complications in 500 postoperative patients
    Haahr-Raunkjaer, Camilla
    Molgaard, Jesper
    Elvekjaer, Mikkel
    Rasmussen, Soren M.
    Achiam, Michael P.
    Jorgensen, Lars N.
    Sogaard, Mette I., V
    Gronbaek, Katja K.
    Oxboll, Anne-Britt
    Sorensen, Helge B. D.
    Meyhoff, Christian S.
    Aasvang, Eske K.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2022, 66 (05) : 552 - 562
  • [43] Continuous recording of vital signs with a wearable device in pediatric patients undergoing chemotherapy for cancer—an operational feasibility study
    Christa Koenig
    Roland A. Ammann
    Claudia E. Kuehni
    Jochen Roessler
    Eva Brack
    Supportive Care in Cancer, 2021, 29 : 5283 - 5292
  • [44] Continuous monitoring of vital sign abnormalities: Association to clinical complications in 500 postoperative patients
    Haahr-Raunkjaer, C.
    Molgaard, J.
    Rasmussen, S. M.
    Elvekjaer, M.
    Achiam, M. P.
    Jorgensen, L. N.
    Sogaard, M. I.
    Gronbaek, K. K.
    Oxboll, A. -B.
    Sorensen, H. B. D.
    Meyhoff, C. S.
    Aasvang, E. K.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2023, 67 (04) : 548 - 548
  • [45] How is My Patient Doing? Evaluating Hospitalized Patients Using Continuous Vital Signs Monitoring
    Zimlichman, Eyal
    Szyper-Kravitz, Martine
    Unterman, Avraham
    Goldman, Anny
    Levkovich, Shiraz
    Shoenfeld, Yehuda
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2009, 11 (06): : 382 - 384
  • [46] Vital signs and estimated blood loss in patients with major trauma: Testing the validity of the ATLS classification of hypovolaemic shock
    Guly, H. R.
    Bouamra, O.
    Spiers, M.
    Dark, P.
    Coats, T.
    Lecky, F. E.
    RESUSCITATION, 2011, 82 (05) : 556 - 559
  • [47] Feasibility of continuous monitoring of vital signs in surgical patients on a general ward: an observational cohort study
    Leenen, Jobbe P. L.
    Dijkman, Eline M.
    van Dijk, Joris D.
    van Westreenen, Henderik L.
    Kalkman, Cor
    Schoonhoven, Lisette
    Patijn, Gijsbert A.
    BMJ OPEN, 2021, 11 (02):
  • [48] Early detection of deteriorating patients in general wards through continuous contactless vital signs monitoring
    Yadav, Ambuj
    Dandu, Himanshu
    Parchani, Gaurav
    Chokalingam, Kumar
    Kadambi, Pooja
    Mishra, Rajesh
    Jahan, Ahsina
    Teboul, Jean-Louis
    Latour, Jos M.
    FRONTIERS IN MEDICAL TECHNOLOGY, 2024, 6
  • [49] Continuous Versus Intermittent Vital Signs Monitoring Using a Wearable, Wireless Patch in Patients Admitted to Surgical Wards: Pilot Cluster Randomized Controlled Trial
    Downey, Candice
    Randell, Rebecca
    Brown, Julia
    Jayne, David G.
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2018, 20 (12)
  • [50] CRITICAL CARE MONITORING IN THE FIELD: PREHOSPITAL CONTINUOUS VITAL SIGNS ACQUISITION IDENTIFIES BEST PREDICTORS OF LIFE-SAVING INTERVENTIONS IN TRAUMA PATIENTS
    Sen, Ayan
    Hu, Peter
    Mackenzie, Colin
    Dutton, Richard
    Jordan, Sean
    Xiao, Yan
    Scalea, Thomas
    CRITICAL CARE MEDICINE, 2009, 37 (12) : A329 - A329