Validity and Reliability of Wearable Sensors for Continuous Postoperative Vital Signs Monitoring in Patients Recovering from Trauma Surgery

被引:2
|
作者
van Melzen, Rianne [1 ]
Haveman, Marjolein E. [2 ]
Schuurmann, Richte C. L. [1 ]
van Amsterdam, Kai [2 ]
El Moumni, Mostafa [3 ]
Tabak, Monique [4 ]
Struys, Michel M. R. F. [2 ]
de Vries, Jean-Paul P. M. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Surg, Div Vasc Surg, NL-9713 GZ Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Anesthesiol, NL-9713 GZ Groningen, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Div Trauma Surg, Dept Surg, NL-9713 GZ Groningen, Netherlands
[4] Univ Twente, Dept Biomed Signals & Syst, NL-7500 AE Enschede, Netherlands
关键词
telemonitoring; validity; accuracy; vital signs; wearable sensor; surgical ward; CORRELATION-COEFFICIENTS; STAFF;
D O I
10.3390/s24196379
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
(1) Background: Wearable sensors support healthcare professionals in clinical decision-making by measuring vital parameters such as heart rate (HR), respiration rate (RR), and blood oxygenation saturation (SpO2). This study assessed the validity and reliability of two types of wearable sensors, based on electrocardiogram or photoplethysmography, compared with continuous monitoring of patients recovering from trauma surgery at the postanesthesia care unit. (2) Methods: In a prospective observational study, HR, RR, SpO2, and temperature of patients were simultaneously recorded with the VitalPatch and Radius PPG and compared with reference monitoring. Outcome measures were formulated as correlation coefficient for validity and mean difference with 95% limits of agreement for reliability for four random data pairs and 30-min pairs per vital sign per patient. (3) Results: Included were 60 patients. Correlation coefficients for VitalPatch were 0.57 to 0.85 for HR and 0.08 to 0.16 for RR, and for Radius PPG, correlation coefficients were 0.60 to 0.83 for HR, 0.20 to 0.12 for RR, and 0.57 to 0.61 for SpO2. Both sensors presented mean differences within the cutoff values of acceptable difference. (4) Conclusions: Moderate to strong correlations for HR and SpO2 were demonstrated. Although mean differences were within acceptable cutoff values for all vital signs, only limits of agreement for HR measured by electrocardiography were considered clinically acceptable.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] The completeness, accuracy and impact on alerts, of wearable vital signs monitoring in hospitalised patients
    Anthony J. Wilson
    Alexander J. Parker
    Gareth B. Kitchen
    Andrew Martin
    Lukas Hughes-Noehrer
    Mahesh Nirmalan
    Niels Peek
    Glen P. Martin
    Fiona C. Thistlethwaite
    BMC Digital Health, 3 (1):
  • [22] Continuous Monitoring of Vital Signs in the General Ward Using Wearable Devices: Randomized Controlled Trial
    Weenk, Mariska
    Bredie, Sebastian J.
    Koeneman, Mats
    Hesselink, Gijs
    van Goor, Harry
    van de Belt, Tom H.
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2020, 22 (06)
  • [23] Vital Signs Prediction and Early Warning Score Calculation Based on Continuous Monitoring of Hospitalised Patients Using Wearable Technology
    Amer, Ahmed Youssef Ali
    Wouters, Femke
    Vranken, Julie
    de Korte-de Boer, Dianne
    Smit-Fun, Valerie
    Duflot, Patrick
    Beaupain, Marie-Helene
    Vandervoort, Pieter
    Luca, Stijn
    Aerts, Jean-Marie
    Vanrumste, Bart
    SENSORS, 2020, 20 (22) : 1 - 21
  • [24] Observational Study of Continuous Vital Signs Monitoring via Medical Grade Wearable Device on Non -ICU Hospitalized Patients
    Adams, Justin
    Weller, Grant
    Ventura, Maria Eloise
    Lamanteer, Michael
    Campbell, F. J.
    Tremper, Kevin
    ANESTHESIA AND ANALGESIA, 2024, 138
  • [25] Design and Evaluation of a Wearable Smart Blanket System for Monitoring Vital Signs of Patients in an Ambulance
    Rezayi, Sorayya
    Safaei, Ali Asghar
    Mohammadzadeh, Niloofar
    JOURNAL OF SENSORS, 2021, 2021
  • [26] A Wearable Nose Clip Sensor System for Monitoring Vital Body Signs of Apnea Patients
    Hao, Yingchao
    Zhang, Wanyu
    Tao, Ruitao
    Zhang, Ziliang
    Zhang, Yujie
    Fan, Shenglong
    Huang, Zubo
    Zhao, Hui
    Liu, Jian
    IEEE SENSORS JOURNAL, 2024, 24 (21) : 35473 - 35480
  • [27] Continuous graphene fibers prepared by liquid crystal spinning as strain sensors for Monitoring Vital Signs
    Liu, Fuyao
    Dong, Yubing
    Shi, Ruike
    Wang, Enliang
    Ni, Qingqing
    Fu, Yaqin
    MATERIALS TODAY COMMUNICATIONS, 2020, 24
  • [28] Experiences of current vital signs monitoring practices and views of wearable monitoring: A qualitative study in patients and nurses
    Areia, Carlos
    King, Elizabeth
    Ede, Jody
    Young, Louise
    Tarassenko, Lionel
    Watkinson, Peter
    Vollam, Sarah
    JOURNAL OF ADVANCED NURSING, 2022, 78 (03) : 810 - 822
  • [29] Current Evidence for Continuous Vital Signs Monitoring by Wearable Wireless Devices in Hospitalized Adults: Systematic Review
    Leenen, Jobbe P. L.
    Leerentveld, Crista
    van Dijk, Joris D.
    van Westreenen, Henderik L.
    Schoonhoven, Lisette
    Patijn, Gijsbert A.
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2020, 22 (06)
  • [30] Integration of Micro Sensors with Mobile Devices for Monitoring Vital Signs of Sleep Apnea Patients
    Zhu, Rong
    Cao, Zhe
    Que, Ruiyi
    2014 9TH IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS), 2014, : 462 - 466