Validity and Reliability of Wearable Sensors for Continuous Postoperative Vital Signs Monitoring in Patients Recovering from Trauma Surgery

被引:2
|
作者
van Melzen, Rianne [1 ]
Haveman, Marjolein E. [2 ]
Schuurmann, Richte C. L. [1 ]
van Amsterdam, Kai [2 ]
El Moumni, Mostafa [3 ]
Tabak, Monique [4 ]
Struys, Michel M. R. F. [2 ]
de Vries, Jean-Paul P. M. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Surg, Div Vasc Surg, NL-9713 GZ Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Anesthesiol, NL-9713 GZ Groningen, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Div Trauma Surg, Dept Surg, NL-9713 GZ Groningen, Netherlands
[4] Univ Twente, Dept Biomed Signals & Syst, NL-7500 AE Enschede, Netherlands
关键词
telemonitoring; validity; accuracy; vital signs; wearable sensor; surgical ward; CORRELATION-COEFFICIENTS; STAFF;
D O I
10.3390/s24196379
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
(1) Background: Wearable sensors support healthcare professionals in clinical decision-making by measuring vital parameters such as heart rate (HR), respiration rate (RR), and blood oxygenation saturation (SpO2). This study assessed the validity and reliability of two types of wearable sensors, based on electrocardiogram or photoplethysmography, compared with continuous monitoring of patients recovering from trauma surgery at the postanesthesia care unit. (2) Methods: In a prospective observational study, HR, RR, SpO2, and temperature of patients were simultaneously recorded with the VitalPatch and Radius PPG and compared with reference monitoring. Outcome measures were formulated as correlation coefficient for validity and mean difference with 95% limits of agreement for reliability for four random data pairs and 30-min pairs per vital sign per patient. (3) Results: Included were 60 patients. Correlation coefficients for VitalPatch were 0.57 to 0.85 for HR and 0.08 to 0.16 for RR, and for Radius PPG, correlation coefficients were 0.60 to 0.83 for HR, 0.20 to 0.12 for RR, and 0.57 to 0.61 for SpO2. Both sensors presented mean differences within the cutoff values of acceptable difference. (4) Conclusions: Moderate to strong correlations for HR and SpO2 were demonstrated. Although mean differences were within acceptable cutoff values for all vital signs, only limits of agreement for HR measured by electrocardiography were considered clinically acceptable.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Evaluation of a wearable, wireless device for remote Vital Signs monitoring in post-operative patients
    Downey, C.
    Jayne, D.
    BRITISH JOURNAL OF SURGERY, 2016, 103 : 85 - 85
  • [32] Continuous vital sign monitoring with Biobeat® wearable devices for post-ambulatory surgery patients: a pilot feasibility study
    Belliveau, Julien
    Pilote, Leo
    Grange, Elliot
    Zaouter, Cedrick
    Roy, Maxim
    Robin, Florian
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2025,
  • [33] Evaluation of a wearable, wireless device for remote vital signs monitoring in post-operative patients
    Downey, C. L.
    Dwyer, M.
    Jayne, D. G.
    BRITISH JOURNAL OF SURGERY, 2016, 103 : 30 - 30
  • [34] Energy Efficient Sensors Data Stream Model for Real-time and Continuous Vital Signs Monitoring
    Ivascu, Todor
    Frincu, Marc
    Negru, Viorel
    PROCEEDINGS OF THE 2016 INTERNATIONAL SYMPOSIUM ON INNOVATIONS IN INTELLIGENT SYSTEMS AND APPLICATIONS (INISTA), 2016,
  • [35] Wearable, compact photo- and speckle plethysmography device for continuous non-invasive vital signs monitoring
    Schnitzler, Lena
    Olazabal, Jorge Herranz
    Lorato, Ilde
    Verhoeven, Marc
    Hermeling, Evelien
    Kling, Jesse
    OPTICAL DIAGNOSTICS AND SENSING XXIV:TOWARD POINT-OF-CARE DIAGNOSTICS, 2024, 12850
  • [36] Practical Considerations and Successful Implementation of Vital Signs Monitoring. Comment on "Continuous Versus Intermittent Vital Signs Monitoring Using a Wearable, Wireless Patch in Patients Admitted to Surgical Wards: Pilot Cluster Randomized Controlled Trial"
    Walsh, Caoimhe
    Zargaran, David
    Patel, Nikhil
    White, Amelia
    Koumpa, Foteini Stefania
    Tanna, Ravina
    Ashraf, Muhammad Arsalan
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2021, 23 (03)
  • [37] Vital signs in pediatric oncology patients assessed by continuous recording with a wearable device, NCT04134429
    Marion Haemmerli
    Roland A. Ammann
    Jochen Roessler
    Christa Koenig
    Eva Brack
    Scientific Data, 9
  • [38] Vital signs in pediatric oncology patients assessed by continuous recording with a wearable device, NCT04134429
    Haemmerli, Marion
    Ammann, Roland A.
    Roessler, Jochen
    Koenig, Christa
    Brack, Eva
    SCIENTIFIC DATA, 2022, 9 (01)
  • [39] Design and Development of a Wristband for Continuous Vital Signs Monitoring of COVID-19 Patients
    Nabavi, Seyedfakhreddin
    Bhadra, Sharmistha
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 6845 - 6850
  • [40] Recommendations for Assessment of the Reliability, Sensitivity, and Validity of Data Provided by Wearable Sensors Designed for Monitoring Physical Activity
    Dueking, Peter
    Fuss, Franz Konstantin
    Holmberg, Hans-Christer
    Sperlich, Billy
    JMIR MHEALTH AND UHEALTH, 2018, 6 (04):