Spinal dura mater: biophysical characteristics relevant to medical device development

被引:35
|
作者
Nagel S.J. [1 ]
Reddy C.G. [2 ]
Frizon L.A. [1 ]
Chardon M.K. [3 ]
Holland M. [2 ]
Machado A.G. [1 ]
Gillies G.T. [4 ]
Howard M.A. [2 ]
Wilson S. [2 ]
机构
[1] Center for Neurological Restoration, Cleveland Clinic, Cleveland, OH
[2] Department of Neurosurgery, University of Iowa Hospitals and Clinics, Iowa City, IA
[3] Department of Physiology, Northwestern University Feinberg School of Medicine, Chicago, IL
[4] Department of Mechanical and Aerospace Engineering, University of Virginia, Charlottesville, VA
来源
基金
美国国家卫生研究院;
关键词
biophysical characteristics; Dura mater; electric stimulation; prostheses and implants; spine surgery;
D O I
10.1080/03091902.2018.1435745
中图分类号
学科分类号
摘要
Understanding the relevant biophysical properties of the spinal dura mater is essential to the design of medical devices that will directly interact with this membrane or influence the contents of the intradural space. We searched the literature and reviewed the pertinent characteristics for the design, construction, testing, and imaging of novel devices intended to perforate, integrate, adhere or reside within or outside of the spinal dura mater. The spinal dura mater is a thin tubular membrane composed of collagen and elastin fibres that varies in circumference along its length. Its mechanical properties have been well-described, with the longitudinal tensile strength exceeding the transverse strength. Data on the bioelectric, biomagnetic, optical and thermal characteristics of the spinal dura are limited and sometimes taken to be similar to those of water. While various modalities are available to visualise the spinal dura, magnetic resonance remains the best modality to segment its structure. The reaction of the spinal dura to imposition of a foreign body or other manipulations of it may compromise its biomechanical and immune-protective benefits. Therefore, dural sealants and replacements are of particular clinical, research and commercial interest. In conclusion, existing devices that are in clinical use for spinal cord stimulation, intrathecal access or intradural implantation largely adhere to traditional designs and their attendant limitations. However, if future devices are built with an understanding of the dura’s properties incorporated more fully into the designs, there is potential for improved performance. © 2018 Informa UK Limited, trading as Taylor & Francis Group.
引用
收藏
页码:128 / 139
页数:11
相关论文
共 50 条
  • [41] Extensive Spinal Adhesive Arachnoiditis After Extradural Spinal Infection-Spinal Dura Mater Is No Barrier to Inflammation
    Kraetzig, Theresa
    Dreimann, Marc
    Mende, Klaus Christian
    Koenigs, Ingo
    Westphal, Manfred
    Eicker, Sven Oliver
    WORLD NEUROSURGERY, 2018, 116 : E1194 - E1203
  • [42] Rectus Capitis Posterior Minor Histological and Biomechanical Links to the Spinal Dura Mater
    Venne, Gabriel
    Rasquinha, Brian J.
    Kunz, Manuela
    Ellis, Randy E.
    SPINE, 2017, 42 (08) : E466 - E473
  • [43] Mast cells populations fluctuate along the spinal dura mater of the developing rat
    Michaloudi, Helen
    Batzios, Christos
    Chiotelli, Maria
    Grivas, Ioannis
    Papadopoulos, Georgios C.
    BRAIN RESEARCH, 2008, 1226 : 8 - 17
  • [44] Dura mater marsupialisation and outcome in a cat with a spinal subarachnoid pseudocyst: a case report
    Pisoni, L.
    Cinti, F.
    Gallucci, A.
    Diana, A.
    Del Magno, S.
    Bellei, E.
    Gandini, G.
    VETERINARNI MEDICINA, 2014, 59 (03) : 157 - 161
  • [45] ULTRASTRUCTURAL CHARACTERISTICS OF THE CRANIAL DURA MATER-ARACHNOID INTERFACE LAYER
    ANGELOV, DN
    ZEITSCHRIFT FUR MIKROSKOPISCH-ANATOMISCHE FORSCHUNG, 1990, 104 (06): : 982 - 990
  • [46] INTRACRANIAL FIBROSARCOMAS OF THE DURA MATER IN CHILDHOOD - PATHOLOGICAL CHARACTERISTICS AND SURGICAL MANAGEMENT
    BAILEY, OT
    INGRAHAM, FD
    JOURNAL OF NEUROSURGERY, 1945, 2 (01) : 1 - &
  • [47] Multi-layered Artificial Dura Mater Models for Medical Surgical Simulators
    Hayakawa, Shusaku
    Takeuchi, Masaru
    Ichikawa, Akihiko
    Hasegawa, Akiyuki
    Uchida, Keisuke
    Fukuda, Toshio
    Huang, Qiang
    2019 IEEE INTERNATIONAL CONFERENCE ON CYBORG AND BIONIC SYSTEMS (CBS), 2019, : 310 - 315
  • [48] Investigation of the material properties of alginate for the development of hydrogel repair of dura mater
    Nunamaker, Elizabeth A.
    Otto, Kevin J.
    Kipke, Daryl R.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2011, 4 (01) : 16 - 33
  • [49] Idiopathic ventral thoracic spinal cord herniation with duplicated dura mater and subarachnoid septum
    Reddy, Ravikanth
    Farha, Furruqh
    Babu, Philip
    NEUROLOGY INDIA, 2017, 65 (04) : 906 - +
  • [50] Idiopathic spinal cord herniation: consideration of its pathogenesis based on the histopathology of the dura mater
    Shimizu, Satoru
    Kobayashi, Yosuke
    Oka, Hidehiro
    Kumabe, Toshihiro
    EUROPEAN SPINE JOURNAL, 2019, 28 (02) : 298 - 305