Spinal dura mater: biophysical characteristics relevant to medical device development

被引:35
|
作者
Nagel S.J. [1 ]
Reddy C.G. [2 ]
Frizon L.A. [1 ]
Chardon M.K. [3 ]
Holland M. [2 ]
Machado A.G. [1 ]
Gillies G.T. [4 ]
Howard M.A. [2 ]
Wilson S. [2 ]
机构
[1] Center for Neurological Restoration, Cleveland Clinic, Cleveland, OH
[2] Department of Neurosurgery, University of Iowa Hospitals and Clinics, Iowa City, IA
[3] Department of Physiology, Northwestern University Feinberg School of Medicine, Chicago, IL
[4] Department of Mechanical and Aerospace Engineering, University of Virginia, Charlottesville, VA
来源
基金
美国国家卫生研究院;
关键词
biophysical characteristics; Dura mater; electric stimulation; prostheses and implants; spine surgery;
D O I
10.1080/03091902.2018.1435745
中图分类号
学科分类号
摘要
Understanding the relevant biophysical properties of the spinal dura mater is essential to the design of medical devices that will directly interact with this membrane or influence the contents of the intradural space. We searched the literature and reviewed the pertinent characteristics for the design, construction, testing, and imaging of novel devices intended to perforate, integrate, adhere or reside within or outside of the spinal dura mater. The spinal dura mater is a thin tubular membrane composed of collagen and elastin fibres that varies in circumference along its length. Its mechanical properties have been well-described, with the longitudinal tensile strength exceeding the transverse strength. Data on the bioelectric, biomagnetic, optical and thermal characteristics of the spinal dura are limited and sometimes taken to be similar to those of water. While various modalities are available to visualise the spinal dura, magnetic resonance remains the best modality to segment its structure. The reaction of the spinal dura to imposition of a foreign body or other manipulations of it may compromise its biomechanical and immune-protective benefits. Therefore, dural sealants and replacements are of particular clinical, research and commercial interest. In conclusion, existing devices that are in clinical use for spinal cord stimulation, intrathecal access or intradural implantation largely adhere to traditional designs and their attendant limitations. However, if future devices are built with an understanding of the dura’s properties incorporated more fully into the designs, there is potential for improved performance. © 2018 Informa UK Limited, trading as Taylor & Francis Group.
引用
收藏
页码:128 / 139
页数:11
相关论文
共 50 条
  • [31] Dopaminergic receptors in rat dura mater: Pharmacological characteristics
    Cavallotti, C
    Frati, A
    Cavallotti, D
    Leali, FMT
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2004, 31 (03): : 190 - 194
  • [32] Development of a Semiautomatic Dura Mater Suturing Device for Preventing Cerebrospinal Fluid Leakage in Transsphenoidal Surgery
    Suzuki, Shohei
    Kobayashi, Etsuko
    Hododuka, Kenichi
    Amano, Kosaku
    Masamune, Ken
    Muragaki, Yoshihiro
    SURGICAL INNOVATION, 2021, 28 (03) : 374 - 377
  • [33] Fabrication of Dry Dura Mater Models for Medical Surgical Simulator
    Hasegawa, Akiyuki
    Ichikawa, Akihiko
    Uchida, Keisuke
    Kotani, Naoki
    Hayakawa, Shusaku
    Takeuchi, Masaru
    Fukuda, Toshio
    2017 IEEE INTERNATIONAL CONFERENCE ON CYBORG AND BIONIC SYSTEMS (CBS), 2017, : 293 - 297
  • [34] The development of the venous sinuses of the dura mater in the human embryo
    Streeter, GL
    AMERICAN JOURNAL OF ANATOMY, 1915, 18 (02): : 145 - 178
  • [35] Mechanical properties of dura mater from the rat brain and spinal cord
    Maikos, Jason T.
    Elias, Ragi A. I.
    Shreiber, David I.
    JOURNAL OF NEUROTRAUMA, 2008, 25 (01) : 38 - 51
  • [36] SPONTANEOUS DISSECTING HEMATOMA OF THE SPINAL DURA-MATER UNDER ANTICOAGULANTS
    SAUTREAUX, JL
    GIROUD, M
    OBADIA, JF
    THIERRY, A
    PRESSE MEDICALE, 1985, 14 (46): : 2348 - 2348
  • [37] Mechanical properties of lumbar dura mater and biomechanics of spinal anesthesia procedure
    Pietrabissa, R
    Mantero, S
    Quaglini, V
    Contro, R
    Runza, M
    COMPUTER METHODS IN BIOMECHANICS & BIOMEDICAL ENGINEERING - 2, 1998, : 355 - 362
  • [38] A new modified dura mater implant: characteristics in recipient dogs
    Shi, Zhi-Dong
    Liu, Ming-Wang
    Qin, Zhong-Zong
    Wang, Qin-Mei
    He, Hai-Yong
    Guo, Ying
    Yu, Zhong-He
    BRITISH JOURNAL OF NEUROSURGERY, 2009, 23 (01) : 71 - 75
  • [40] Biological Effects of Clinically Relevant CoCr Nanoparticles in the Dura Mater: An Organ Culture Study
    Papageorgiou, Iraklis
    Abberton, Thomas
    Fuller, Martin
    Tipper, Joanne L.
    Fisher, John
    Ingham, Eileen
    NANOMATERIALS, 2014, 4 (02): : 485 - 504