Spinal dura mater: biophysical characteristics relevant to medical device development

被引:35
|
作者
Nagel S.J. [1 ]
Reddy C.G. [2 ]
Frizon L.A. [1 ]
Chardon M.K. [3 ]
Holland M. [2 ]
Machado A.G. [1 ]
Gillies G.T. [4 ]
Howard M.A. [2 ]
Wilson S. [2 ]
机构
[1] Center for Neurological Restoration, Cleveland Clinic, Cleveland, OH
[2] Department of Neurosurgery, University of Iowa Hospitals and Clinics, Iowa City, IA
[3] Department of Physiology, Northwestern University Feinberg School of Medicine, Chicago, IL
[4] Department of Mechanical and Aerospace Engineering, University of Virginia, Charlottesville, VA
来源
基金
美国国家卫生研究院;
关键词
biophysical characteristics; Dura mater; electric stimulation; prostheses and implants; spine surgery;
D O I
10.1080/03091902.2018.1435745
中图分类号
学科分类号
摘要
Understanding the relevant biophysical properties of the spinal dura mater is essential to the design of medical devices that will directly interact with this membrane or influence the contents of the intradural space. We searched the literature and reviewed the pertinent characteristics for the design, construction, testing, and imaging of novel devices intended to perforate, integrate, adhere or reside within or outside of the spinal dura mater. The spinal dura mater is a thin tubular membrane composed of collagen and elastin fibres that varies in circumference along its length. Its mechanical properties have been well-described, with the longitudinal tensile strength exceeding the transverse strength. Data on the bioelectric, biomagnetic, optical and thermal characteristics of the spinal dura are limited and sometimes taken to be similar to those of water. While various modalities are available to visualise the spinal dura, magnetic resonance remains the best modality to segment its structure. The reaction of the spinal dura to imposition of a foreign body or other manipulations of it may compromise its biomechanical and immune-protective benefits. Therefore, dural sealants and replacements are of particular clinical, research and commercial interest. In conclusion, existing devices that are in clinical use for spinal cord stimulation, intrathecal access or intradural implantation largely adhere to traditional designs and their attendant limitations. However, if future devices are built with an understanding of the dura’s properties incorporated more fully into the designs, there is potential for improved performance. © 2018 Informa UK Limited, trading as Taylor & Francis Group.
引用
收藏
页码:128 / 139
页数:11
相关论文
共 50 条
  • [21] Damage accumulation modeling and rate dependency of spinal dura mater
    Ramo, Nicole
    Shetye, Snehal S.
    Puttlitz, Christian M.
    Journal of Engineering and Science in Medical Diagnostics and Therapy, 2018, 1 (01)
  • [22] A Technique for In Vitro Studying of the Permeability of the Spinal Cord Dura Mater
    V. V. Krasnov
    M. V. Stogov
    T. A. Silant’eva
    N. V. Kubrak
    E. A. Kireeva
    Bulletin of Experimental Biology and Medicine, 2018, 164 : 402 - 403
  • [23] PRESUMED MYELOPOIESIS IN SPINAL DURA MATER OF NORMAL BOVINE FETUSES
    TERLECKI, S
    BRADLEY, R
    JOURNAL OF COMPARATIVE PATHOLOGY, 1983, 93 (03) : 347 - 352
  • [24] DAMAGE ACCUMULATION MODELING AND RATE DEPENDENCY OF SPINAL DURA MATER
    Ramo, Nicole L.
    Shetye, Snehal S.
    Puttlitz, Christian M.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2017, VOL 3, 2018,
  • [25] Histological Investigation of Resected Dura Mater Attached to Spinal Meningioma
    Yamamuro, Kenichi
    Seichi, Atsushi
    Kimura, Atsushi
    Kikkawa, Ichiro
    Kojima, Masahiro
    Inoue, Hirokazu
    Hoshino, Yuichi
    SPINE, 2012, 37 (22) : E1398 - E1401
  • [26] Investigation of connective tissue attachments to the cervical spinal dura mater
    Humphreys, BK
    Kenin, S
    Hubbard, BB
    Cramer, GD
    CLINICAL ANATOMY, 2003, 16 (02) : 152 - 159
  • [27] A case of idiopathic spinal cord herniation with duplicated dura mater
    Sugimoto, T
    Kasai, Y
    Takegami, K
    Morimoto, R
    Maeda, M
    Uchida, A
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2005, 18 (01): : 106 - 111
  • [28] Effects of Radiation on Spinal Dura Mater and Surrounding Tissue in Mice
    Yokogawa, Noriaki
    Murakami, Hideki
    Demura, Satoru
    Kato, Satoshi
    Yoshioka, Katsuhito
    Yamamoto, Miyuki
    Iseki, Shoichi
    Tsuchiya, Hiroyuki
    PLOS ONE, 2015, 10 (07):
  • [29] A Technique for In Vitro Studying of the Permeability of the Spinal Cord Dura Mater
    Krasnov, V. V.
    Stogov, M. V.
    Silant'eva, T. A.
    Kubrak, N. V.
    Kireeva, E. A.
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2018, 164 (03) : 402 - 403
  • [30] The nerve termination in dura mater of the spinal marrow of mammals.
    Wreden, J
    ARCHIV FUR MIKROSKOPISCHE ANATOMIE UND ENTWICKLUNGSGESCHICHTE, 1905, 66 : 128 - 134