Imaging Property of Inverse Geometry Micro-CT with Micro Multi-focus X-ray Source Based on Electron Beam Scanning

被引:0
|
作者
Zhou, Rifeng [1 ,2 ,3 ]
Tang, Jie [1 ,2 ]
Hu, Xiaolong [1 ,2 ]
Xie, Dongyang [1 ,2 ]
Liu, Yuchuan [1 ,2 ]
机构
[1] Engineering Research Center of Industrial CT Nondestructive Testing of Ministry of Education, Chongqing,400044, China
[2] ICT Research Center, Key Lab of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing,400044, China
[3] State Key Laboratory of Mechanical Transmission, Chongqing University, Chongqing,400044, China
来源
Yuanzineng Kexue Jishu/Atomic Energy Science and Technology | 2021年 / 55卷 / 12期
关键词
Electron sources - Electron beams - Iterative methods - Geometry - Computerized tomography - Signal to noise ratio - Scanning - Inverse problems - Redundancy - X ray detectors;
D O I
暂无
中图分类号
学科分类号
摘要
In theory, inverse geometry CT has the advantages of larger scanning field, higher signal-to-noise ratio and fewer cone beam artifacts. However, in the multi-focus and sparse angle scanning mode, the projection data also has some problems such as data truncation, sparseness and local redundancy. An inverse geometry Micro-CT experimental system (IG-Micro-CT) with high resolution and large field of view was constructed by using electron beam scanning array micro multi-focal X-ray source and small area high-resolution detector. In view of the characteristics of multi-focal, sparse angle scanning mode projection data truncation and sparseness, a relative prior image guided SART iterative CT image reconstruction algorithm was proposed. Firstly, the algorithm was verified by simulation experiments, and the scanning parameters such as the number of ray source focus were optimized. Finally, high-resolution Micro-CT test images were obtained on the IG-Micro-CT experimental system. The experimental results show that the proposed algorithm can solve the problems of strip and truncation artifacts caused by projection data truncation, sparse sampling and local data redundancy. Besides, the feasibility of this new imaging method of IG-Micro-CT was verified, which lays a foundation for the practical application of IG-Micro-CT system. © 2021, Editorial Board of Atomic Energy Science and Technology. All right reserved.
引用
收藏
页码:2374 / 2381
相关论文
共 50 条
  • [41] In-Line Method of X-ray Phase-Contrast Micro-CT Using a Wide-Focus Laboratory Source
    Krivonosov, Yu. S.
    Buzmakov, A. V.
    Asadchikov, V. E.
    Fyodorova, A. A.
    CRYSTALLOGRAPHY REPORTS, 2023, 68 (02) : 203 - 209
  • [42] In-vivo X-Ray micro-imaging and micro-CT with the Medipix2 semiconductor detector at UniAndes
    Caicedo, I.
    Avila, C.
    Gomez, B.
    Bula, C.
    Roa, C.
    Sanabria, J.
    IX LATIN AMERICAN SYMPOSIUM ON NUCLEAR PHYSICS AND APPLICATIONS, 2012, 1423
  • [43] Comparison of fan-beam, cone-beam and spiral scan reconstruction for x-ray micro-CT
    Sasov, A
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 711 - 718
  • [44] Comparison of fan-beam, cone-beam and spiral scan reconstruction in X-ray micro-CT
    Sasov, A
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 124 - 131
  • [45] Using X-ray micro-CT imaging to monitor dissolution of macroporous bioactive glass scaffolds
    Jones, JR
    Milroy, GE
    Cameron, RE
    Bonfield, W
    Hench, LL
    BIOCERAMICS 17, 2005, 284-286 : 493 - 496
  • [46] Environmental cell for in situ X-ray synchrotron micro-CT imaging with simultaneous acoustic measurements
    Drobchik, Arkady N.
    Nikitin, Viktor V.
    Fokin, Mikhail, I
    Dugarov, Geser A.
    Shevchenko, Pavel D.
    Deriy, Alex L.
    Manakov, Andrey Yu
    Kuper, Konstantin E.
    Duchkov, Anton A.
    JOURNAL OF SYNCHROTRON RADIATION, 2022, 29 : 515 - 521
  • [47] X-ray Micro-CT and DVC Based Analysis of Strains in Metallization of Flexible Electronics
    Lall, Pradeep
    Wei, Junchao
    PROCEEDINGS OF THE 2017 SIXTEENTH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS ITHERM 2017, 2017, : 1253 - 1261
  • [48] Thermo-stamping shear characteristics of thermoplastics based on X-ray micro-CT
    Wang, Zhen
    Chen, Yisong
    Zhu, Guohua
    MATERIALS AND MANUFACTURING PROCESSES, 2023, 38 (06) : 668 - 679
  • [49] Fracturing Mechanism of Compressed Hollow-Cylinder Sandstone Evaluated by X-ray Micro-CT Scanning
    Sheng-Qi Yang
    Rock Mechanics and Rock Engineering, 2018, 51 : 2033 - 2053
  • [50] Characterisation of 'Braeburn' browning disorder by means of X-ray micro-CT
    Herremans, Els
    Verboven, Pieter
    Bongaers, Evi
    Estrade, Pascal
    Verlinden, Bert E.
    Wevers, Martine
    Hertog, Maarten L. A. T. M.
    Nicolai, Bart M.
    POSTHARVEST BIOLOGY AND TECHNOLOGY, 2013, 75 : 114 - 124