Characterisation of 'Braeburn' browning disorder by means of X-ray micro-CT

被引:135
|
作者
Herremans, Els [1 ]
Verboven, Pieter [1 ]
Bongaers, Evi [2 ]
Estrade, Pascal [3 ]
Verlinden, Bert E. [4 ]
Wevers, Martine [5 ]
Hertog, Maarten L. A. T. M. [1 ]
Nicolai, Bart M. [1 ,4 ]
机构
[1] Catholic Univ Louvain, BIOSYST MeBioS, B-3001 Louvain, Belgium
[2] Bruker MicroCT, B-2550 Kontich, Belgium
[3] VSG, F-33708 Merignac, France
[4] Flanders Ctr Postharvest Technol, B-3001 Louvain, Belgium
[5] Catholic Univ Louvain, Dept Met & Mat Engn, B-3001 Louvain, Belgium
关键词
Apple; 'Braeburn' browning disorder; Microstructure; Internal fruit quality; X-ray micro-CT; CONTROLLED-ATMOSPHERE STORAGE; PYRUS-COMMUNIS L; CONFERENCE PEARS; CORE BREAKDOWN; GAS-TRANSPORT; APPLE TISSUE; FRUIT; QUANTIFICATION; MODEL; MICROTOMOGRAPHY;
D O I
10.1016/j.postharvbio.2012.08.008
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
Unfavourable gas conditions during controlled atmosphere storage may cause browning symptoms in 'Braeburn' apple fruit ('Braeburn' browning disorder or BBD). These symptoms are likely to reflect massive changes in the microstructure of the fruit tissue. In this study, individual cells, the internal air network and the 3-D distribution of pores inside 'Braeburn' apple tissue were examined using high resolution X-ray micro computed tomography. Different stages of BBD could be clearly resolved on the virtual cross-sections, granting a unique 3-D insight in tissue flooding and formation of cavities in 'Braeburn' tissue during the development of the disorder. Image analysis methods were applied to extract morphometric parameters such as porosity, anisotropy and connectivity to characterise microstructure. The discriminative power of these descriptors was proven by their ability to classify fruit tissue as healthy and disordered with a success rate of 97%. The observed distinct radial patterns of porosity, anisotropy and connectivity may help in explaining why 'Braeburn' is susceptible to BBD. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:114 / 124
页数:11
相关论文
共 50 条
  • [1] Virtual characterisation of porcupine quills using X-ray micro-CT
    Tee, Yun Lu
    Black, Jay R.
    Phuong Tran
    VIRTUAL AND PHYSICAL PROTOTYPING, 2023, 18 (01)
  • [2] MICROSTRUCTURE CHARACTERIZATION BY MEANS OF X-RAY MICRO-CT AND NANOINDENTATION MEASUREMENTS
    Rajczakowska, Magdalena
    Stefaniuk, Damian
    Lydzba, Dariusz
    STUDIA GEOTECHNICA ET MECHANICA, 2015, 37 (01) : 75 - 84
  • [3] 3D pore structure analysis of intact 'Braeburn' apples using X-ray micro-CT
    Janssen, Siem
    Verboven, Pieter
    Nugraha, Bayu
    Wang, Zi
    Boone, Matthieu
    Josipovic, Ivan
    Nicolai, Bart M.
    POSTHARVEST BIOLOGY AND TECHNOLOGY, 2020, 159
  • [4] Desktop x-ray micro-CT instruments
    Sasov, A
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 282 - 290
  • [5] Quantitative Study of Porosity and Pore Features in Moldavites by Means of X-ray Micro-CT
    Pratesi, Giovanni
    Caporali, Stefano
    Loglio, Francesca
    Giuli, Gabriele
    Dzikova, Lenka
    Skala, Roman
    MATERIALS, 2014, 7 (04): : 3319 - 3336
  • [6] An experimental micro-CT system for X-ray NDT
    Rossi, M
    Casali, F
    Bettuzzi, M
    Morigi, MP
    Romani, A
    Golovkin, SV
    Govorun, VN
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 338 - 348
  • [7] X-ray micro-CT with a displaced detector array
    Wang, G
    MEDICAL PHYSICS, 2002, 29 (07) : 1634 - 1636
  • [8] Development of X-ray CCD camera based X-ray micro-CT system
    Sarkar, Partha S.
    Ray, N. K.
    Pal, Manoj K.
    Baribaddala, Ravi
    Agrawal, Ashish
    Kashyap, Y.
    Sinha, A.
    Gadkari, S. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (02):
  • [9] Accurate Resolution Measurement for X-Ray Micro-CT Systems
    Sen Sharma, K.
    Seshadri, S.
    Feser, M.
    Wang, G.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 337 - 340
  • [10] Micro-CT of small insects by projection X-ray microscopy
    Tanisako, Akira
    Tsuruta, Susumu
    Hori, Ayumi
    Okumura, Aya
    Miyata, Chikara
    Kuzuryu, Chiaki
    Obi, Takashi
    Yoshimura, Hideyuki
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318