Imaging Property of Inverse Geometry Micro-CT with Micro Multi-focus X-ray Source Based on Electron Beam Scanning

被引:0
|
作者
Zhou, Rifeng [1 ,2 ,3 ]
Tang, Jie [1 ,2 ]
Hu, Xiaolong [1 ,2 ]
Xie, Dongyang [1 ,2 ]
Liu, Yuchuan [1 ,2 ]
机构
[1] Engineering Research Center of Industrial CT Nondestructive Testing of Ministry of Education, Chongqing,400044, China
[2] ICT Research Center, Key Lab of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing,400044, China
[3] State Key Laboratory of Mechanical Transmission, Chongqing University, Chongqing,400044, China
来源
Yuanzineng Kexue Jishu/Atomic Energy Science and Technology | 2021年 / 55卷 / 12期
关键词
Electron sources - Electron beams - Iterative methods - Geometry - Computerized tomography - Signal to noise ratio - Scanning - Inverse problems - Redundancy - X ray detectors;
D O I
暂无
中图分类号
学科分类号
摘要
In theory, inverse geometry CT has the advantages of larger scanning field, higher signal-to-noise ratio and fewer cone beam artifacts. However, in the multi-focus and sparse angle scanning mode, the projection data also has some problems such as data truncation, sparseness and local redundancy. An inverse geometry Micro-CT experimental system (IG-Micro-CT) with high resolution and large field of view was constructed by using electron beam scanning array micro multi-focal X-ray source and small area high-resolution detector. In view of the characteristics of multi-focal, sparse angle scanning mode projection data truncation and sparseness, a relative prior image guided SART iterative CT image reconstruction algorithm was proposed. Firstly, the algorithm was verified by simulation experiments, and the scanning parameters such as the number of ray source focus were optimized. Finally, high-resolution Micro-CT test images were obtained on the IG-Micro-CT experimental system. The experimental results show that the proposed algorithm can solve the problems of strip and truncation artifacts caused by projection data truncation, sparse sampling and local data redundancy. Besides, the feasibility of this new imaging method of IG-Micro-CT was verified, which lays a foundation for the practical application of IG-Micro-CT system. © 2021, Editorial Board of Atomic Energy Science and Technology. All right reserved.
引用
收藏
页码:2374 / 2381
相关论文
共 50 条
  • [31] Micro-CT X-ray imaging exposes structured diffusion barriers within biofilms
    Keren-Paz, Alona
    Brumfeld, Vlad
    Oppenheimer-Shaanan, Yaara
    Kolodkin-Gal, Ilana
    NPJ BIOFILMS AND MICROBIOMES, 2018, 4
  • [32] Micro-CT of small insects by projection X-ray microscopy
    Tanisako, Akira
    Tsuruta, Susumu
    Hori, Ayumi
    Okumura, Aya
    Miyata, Chikara
    Kuzuryu, Chiaki
    Obi, Takashi
    Yoshimura, Hideyuki
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [33] Micro-CT scanner with a focusing polycapillary x-ray optic
    Jorgensen, SM
    Reyes, DA
    MacDonald, CA
    Ritman, EL
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 158 - 166
  • [34] X-ray Micro-CT based characterization of rock cuttings with deep learning
    Olsen, Nils
    Chen, Yifeng
    Turberg, Pascal
    Moreau, Alexandre
    Alahi, Alexandre
    APPLIED COMPUTING AND GEOSCIENCES, 2025, 25
  • [35] Micro-CT of Pseudocneorhinus bifasciatus by projection X-ray microscopy
    Tanisako, A
    Hori, A
    Okumura, A
    Miyata, C
    Kuzuryu, C
    Obi, T
    Yoshimura, H
    JOURNAL OF ELECTRON MICROSCOPY, 2005, 54 (04): : 379 - 383
  • [36] Research and Development on X-ray Micro-CT System for MEMS
    Fu Jian
    Li Bin
    Zhou Zhenggan
    Wei Dongbo
    Zhou Xingyu
    ISTM/2009: 8TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, 2009, : 1947 - 1950
  • [37] Laboratory-based multi-modal X-ray microscopy and micro-CT with Bragg magnifiers
    Vagovic, P.
    Korytar, D.
    Cecilia, A.
    Hamann, E.
    Baumbach, T.
    Pelliccia, D.
    OPTICS EXPRESS, 2015, 23 (14): : 18391 - 18400
  • [38] X-ray Dose Quantification for Various Scanning Protocols with the GE eXplore 120 micro-CT
    Bretin, Florian
    Bahri, Mohamed A.
    Warnock, Geoffrey I.
    Luxen, Andre
    Seret, Alain
    Plenevaux, Alain
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3775 - 3777
  • [39] Study of the x-ray source with micro-beam
    Wang, KG
    Niu, HB
    BIOMEDICAL PHOTONICS AND OPTOELECTRONIC IMAGING, 2000, 4224 : 101 - 104
  • [40] In-Line Method of X-ray Phase-Contrast Micro-CT Using a Wide-Focus Laboratory Source
    Yu. S. Krivonosov
    A. V. Buzmakov
    V. E. Asadchikov
    A. A. Fyodorova
    Crystallography Reports, 2023, 68 : 203 - 209