Issues and improvements in commercial kitchen exhaust ducts

被引:0
|
作者
Horton, Doug [1 ]
机构
[1] D. J. HORTON, Batavia,IL, United States
来源
Engineered Systems | 2015年 / 32卷 / 01期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Applicable codes and standards provide requirements for exhaust ducts connected to Type I exhaust hoods. Welded-on-site ducts that are not tested and listed to national consensus standards are hereafter referred to as unlisted ducts. The Minnesota Mechanical Code, in section 506.4.2, requires evaluation of duct leakage by means of an air pressure test. Ducts must hold positive air pressure of 1.0 inch water column for a minimum of 20 minutes unless an equivalent alternate test is specified by the building official. A largely unknown fire risk with leaking kitchen exhaust ducts was discovered by a listing agency conducting a UL Standard 300 test of a prototype fire suppression system. The equipment included a UL 710 listed hood over a natural gas-fueled deep fat fryer. With the exhaust duct pre-heated as required, the deep fat fryer was ignited, and after the specified pre-burn time, the water and surfactant based fire suppression system was activated.
引用
收藏
页码:42 / 49
相关论文
共 50 条
  • [41] Rapid improvements with no commercial production: How do the improvements occur?
    Funk, Jeffrey L.
    Magee, Christopher L.
    RESEARCH POLICY, 2015, 44 (03) : 777 - 788
  • [42] Saturated buffers: Improvements and issues
    Eldridge, Emma E.
    Schoonover, Jon E.
    Williard, Karl W. J.
    Sadeghpour, Amir
    Gillespie, Jackie C.
    JOURNAL OF ENVIRONMENTAL QUALITY, 2024, 53 (02) : 232 - 240
  • [43] Using DCCP: Issues and Improvements
    Schier, Michael
    Welzl, Michael
    2012 20TH IEEE INTERNATIONAL CONFERENCE ON NETWORK PROTOCOLS (ICNP), 2012,
  • [44] Analysis of temperature and exhaust gases distribution in residential kitchen of LIG house
    Pal, Chaman Lal
    Netam, Nisha
    MATERIALS TODAY-PROCEEDINGS, 2021, 44 : 3025 - 3031
  • [45] Research on the Optimal Selection of Exhaust Range-hood in Chinese Kitchen
    Ao, Yongan
    Jia, Xin
    Wang, Li
    Gu, Chao
    CONFERENCE ON ENVIRONMENTAL POLLUTION AND PUBLIC HEALTH, VOL 1-2, 2010, : 159 - 162
  • [46] The benefit of kitchen exhaust fan use after cooking - An experimental assessment
    Dobbin, Nina A.
    Sun, Liu
    Wallace, Lance
    Kulka, Ryan
    You, Hongyu
    Shin, Tim
    Aubin, Daniel
    St-Jean, Melissa
    Singer, Brett C.
    BUILDING AND ENVIRONMENT, 2018, 135 : 286 - 296
  • [47] Controllable baffle-type exhaust-hood in home kitchen
    Xunxing, Song
    Wei, Yin
    Hao, Xiaoli
    INTERNATIONAL JOURNAL OF VENTILATION, 2024, 23 (04) : 309 - 327
  • [48] Effects of Commercial Kitchen Detergents on Adhesion and Viability of Bacteria
    Miyamoto, Takahisa
    Ohishi, Akinobu
    Kawagishi, Johtaro
    Ishibashi, Akiko
    Kinoshita, Yoshimasa
    Mekada, Youko
    Honjoh, Ken-ichi
    JOURNAL OF THE JAPANESE SOCIETY FOR FOOD SCIENCE AND TECHNOLOGY-NIPPON SHOKUHIN KAGAKU KOGAKU KAISHI, 2011, 58 (03): : 127 - 130
  • [49] Dedicated outdoor air system for commercial kitchen ventilation
    Brown, Stephen L.
    ASHRAE JOURNAL, 2007, 49 (07) : 24 - +
  • [50] Test and analysis on thermal environment of commercial kitchen in China
    Hou, Xiaotan
    Wang, Zhihua
    Li, Angui
    ADVANCES IN INDUSTRIAL AND CIVIL ENGINEERING, PTS 1-4, 2012, 594-597 : 2154 - 2157